Truma Combi 2 E Скачать руководство пользователя страница 5

5

EN

smoke and / or smell due to dust or dirt. It is 
a good idea to allow the appliance to run at 
maximum output for a few minutes for the 
purpose of self-cleaning and to ensure that 
the area is well ventilated.

– Hot air can be dangerous particularly to 

toddlers, children, older or infirm people 
and can cause burn injuries. The air flowing 
out can reach high temperatures at the hot 
air vents. Check the air temperature at the 
warm air outlets regularly.

– Hot water can be dangerous particularly 

to toddlers, children, older or infirm people 
and can cause burn injuries. Check the wa-
ter temperature every time before taking a 
shower or bath. 

 

Caution!

 Some parts of the product can be-

come very hot and cause burn injuries. Par-
ticular caution is required when children and 
vulnerable persons are present.

 

– Children aged under 3 years must be 

kept away unless they are under constant 
supervision.

 

– Children aged over 3 years and under 

8 years may only switch the appliance on 
and off if they are under supervision or if 
they have been instructed on how to safely 
use the appliance and have understood the 
potential dangers, and provided that the ap-
pliance is located or installed in its normal 
place of use. Children aged over 3 years and 
under 8 years may not insert the plug into 
the socket, regulate the appliance, clean the 
appliance and / or perform user maintenance

– This appliance may be used by children from 

8 years old and by persons with reduced 
physical, sensory or mental capabilities or 
with a lack of experience and knowledge 
only if they are supervised or have been in-
structed in the safe use of the appliance and 
understand the resulting risks. Children must 
not be allowed to play with the appliance. 

– The integrity and tight fit of the exhaust dou-

ble duct must be checked regularly, particu-
larly at the end of long trips. Also check the 
mounting of the appliance and the cowl.

Operation while driving

– For heating while driving, the directive 

UN ECE R 122 for motor caravans and cara-
vans specifies a safety shut-off device in 
order to prevent the uncontrolled escape of 
gas in the event of an accident. The  Truma 
 MonoControl CS gas pressure regulator sat-
isfies this requirement. Throughout  Europe, 
a type-tested liquid gas heater may be 
used while driving (according to Directive 
UN ECE R 122) if the system includes this 
regulator with an appropriately configured 
gas installation. National regulations and 
rules must be followed.

– If 

no

 safety shut-off device (e.g. as contained 

within the  Truma   MonoControl  CS gas pres-
sure regulator) is installed, the gas cylinder 
must be closed when driving and 

informa-

tion signs

 must be attached in the gas cyl-

inder protection box and in the vicinity of the 
control panel.

 

Never use LP gas appliances when 
refuelling, in multi-storey car parks, in 

garages or on ferries. Switch off the LP gas 
appliance at the control panel. Make sure that 
the LP gas appliance can never be switched 
on via a remote control e.g the  Truma App.

– To prevent damage to the appliance from 

spray water, such as when cleaning the vehi-
cle, do not spray water directly into the cowl.

Troubleshooting

– If you notice unusual noises or smells, close 

off the gas supply and switch off the Combi.

– Danger of fire / explosion if you attempt to 

use a Combi that has been damaged by the 
ingress of liquid (e.g. beverages, flooding, 
leaks) or if the vehicle has been involved in 
an accident. A damaged Combi must be 
repaired by an expert or replaced.

– Have faults repaired by an expert without 

delay.

– Only carry out repairs yourself if the solution 

is described in the troubleshooting guide of 
these operating instructions.

– Following an deflagration (misfire), have the 

appliance and exhaust gas system inspected 
by an expert.

Содержание Combi 2 E

Страница 1: ...EN Operating instructions To be kept in the vehicle Combi E Page 02 ...

Страница 2: ...al 10 Faults 11 Troubleshooting guide water supply 11 Accessories 11 Manufacturer s Warranty European Union 12 Combi E Geändert Ludsteck 2017 17 18 2 3 5 7 8 9 11 10 14 15 16 4 12 13 6 6 1 Figure 1 Symbols used Symbol indicates possible hazards Note containing information and tips Observe the ESD regulations Intended use Proper use The appliance is approved solely for installation and opera tion i...

Страница 3: ... smoke Open windows and doors Evacuate all persons from the vehicle Shut off gas cylinders and or shut off the gas supply from the outside Have the entire gas system inspected and repaired by experts Do not put the gas system back into opera tion until it has been inspected and repaired Working on the appliance in the installation compartment Possible danger from electric shock or explosion as a r...

Страница 4: ... relevant national regulations in Germany every 2 years The test must be confirmed on the respective test certificate G 607 Pressure regulating devices and hoses must be replaced with new ones no more than 10 years after their date of manufacture every 8 years if used commercially Inspect hose lines regularly and have them replaced if they are broken Safe operation The exhaust cowl must not be blo...

Страница 5: ...le duct must be checked regularly particu larly at the end of long trips Also check the mounting of the appliance and the cowl Operation while driving For heating while driving the directive UN ECE R 122 for motor caravans and cara vans specifies a safety shut off device in order to prevent the uncontrolled escape of gas in the event of an accident The Truma MonoControl CS gas pressure regulator s...

Страница 6: ...red this is possible in hot water mode In hot water mode the water is heated at the lowest burner setting Once the water temperature has been reached the burner switches off In heating mode the appliance automatically selects the required operating level according to the temperature dif ference between the temperature set on the control panel and the current room temperature If the boiler has been...

Страница 7: ...nage socket led outside through floor of vehicle Operating instructions Heating mode In heating mode the appliance automatically selects the required operating level according to the temperature differ ence between the temperature set on the control panel and the current room temperature If the water container has been filled the water is automatically heated as well The water temperature depends ...

Страница 8: ...al position a or b Filling the water Check whether the safety drain valve is closed see Closing the safety drain valve When the temperature at FrostControl is below approx 7 C first switch on the heater to warm the installation compartment and FrostControl After several minutes when the temperature at FrostControl is above 7 C the safety drain valve can be closed Switch on the power for the pump a...

Страница 9: ...on for at least 30 minutes and no hot water may be removed The residual heat in the heat exchanger will heat the water up to 70 C Solar systems When a solar system is used EN 1648 stipulates that a battery with charge regulator or a voltage regulator output voltage 11 V 15 V alternating voltage ripple 1 2 Vss must be connected between the solar system and the heater at all times Otherwise the heat...

Страница 10: ...s consumption Combi 2 E UK 160 g h Combi 4 E 160 335 g h Combi 6 E 160 460 g h Standby heat requirement all appliances Gas mode 8 6 g h measured in accordance with EN 15033 Additional information according to EN 624 Combi 2 E UK Qn 2 4 kW Hs 170 g h C13 I3 B P 30 Combi 4 E Qn 4 8 kW Hs 345 g h C13 I3 B P 30 Combi 6 E Qn 6 8 kW Hs 480 g h C13 I3 B P 30 Destination countries Combi 2 E UK GB IE Combi...

Страница 11: ...ent for FrostControl The FrostControl can no longer be closed Temperature at FrostControl less than approx 7 C Switch heater on Without heater operation the FrostControl cannot be closed again until the temperature reaches ap prox 7 C Rotary switch is not set to Operation Turn the rotary switch of the FrostControl to Operation then press the pushbutton until it engages If these actions do not reme...

Страница 12: ...2 Warranty exclusions No warranty claim shall be applicable under the following circumstances Improper unsuitable faulty or negligent use and any use that is not compliant with the intended purpose Improper installation assembly or commissioning contrary to operating or installation instructions Improper operation or operation contrary to operating or installation instructions particularly any dis...

Страница 13: ...89 4617 2020 Telefax 49 0 89 4617 2159 service truma com www truma com EN Should problems occur please contact the Truma Service Centre or one of our authorised service partners see www truma com In order to avoid delays please have the unit model and serial number ready see type plate 34020 00851 00 11 2019 ...

Отзывы: