background image

9

EN

 

– Check to make sure the cowl is unobstructed. Be sure to 

remove any covers that may be present.

It is forbidden to fit cowl covers.

 

– Open the gas cylinder and the quick-acting valve in the gas 

supply line.

 

– If necessary, fill the water container with water (see “Filling 

the water container”).

 

– Switch on the appliance on the control panel.

Switching off

 

– Switch the heater off on the control panel. 

 

– The switch-off procedure may be delayed by several min-

utes because of internal heater operations.

Always drain water contents if there is a risk of frost!

If the appliance is not used for a long period, close the quick-

acting valve in the gas supply line and the gas cylinder.

Maintenance

Maintenance, repairs and cleaning must not be done by 

children.

Work by experts 

 

– Have an expert check the appliance for dirt and clean it if 

necessary.

Work to be done by the user

 

– Clean the compartment where the appliance is installed at 

least once annually.

 

– The safety / drain valve must be operated regularly (at least 

twice annually) to remove limescale deposits and to be cer-

tain that it is not blocked.

Notes on cleaning, sterilising and care

We recommend the use of suitable, commercially available 

products to clean, sterilise and maintain the boiler. Products 

containing chlorine must not be used.

The effectiveness of the use of chemicals to combat micro-

organisms in the appliance can be increased by heating the 

water in the boiler to 70 °C at regular intervals.

 

– Select “gas mode” on the control panel.

 

– Set the water temperature to 60 °C. 

 

– Switch on the appliance.

Once the water in the water container has reached a 

temperature of 60 °C, the burner will switch off. The ap-

pliance must remain switched on for at least 30 minutes and 

no hot water may be removed. The residual heat in the heat 

exchanger will heat the water up to 70 °C.

Solar systems

When a solar system is used, EN 1648 stipulates that 

a battery (with charge regulator) or a voltage regulator 

(output voltage 11 V – 15 V; alternating voltage ripple < 1.2 Vss) 

must be connected between the solar system and the heater at 

all times. Otherwise, the heater electronics can be damaged by 

an irregular voltage supply from the solar system.

 

– When disconnecting the battery, always disconnect the 

charge regulator from the battery first.

 

– When connecting the battery, always connect the charge 

regulator to the battery last.

We provide no warranty on heater electronics that have 

been damaged by an irregular voltage supply from the 

solar system.

Fuses

Electrostatic charging can destroy the electronics. 

Ensure that potential compensation is present before 

touching the electronics.

Fuse 12 V 

Before opening the connection cover, disconnect the 

appliance at all poles from the 12 V voltage supply.

The fuse is in the electronics beneath the connection cover. 

Always replace the fuse of the appliance with an identical 

fuse.

Appliance fuse: 10 A – quick-acting – 5 x 20 mm (F 10 A)

F 10 A

Figure 5

After replacing the fuse and resetting the overheating 

protection, the connection cover must be put back in 

order to protect the appliance electronics against dripping 

water.

230 V   fuse ( Combi E)

Risk to life from electric shock when changing the 

fuse or the power supply lines. 

 

– The fuse and the power supply lines must only be replaced 

by an expert.

 

– The appliance must be disconnected from the mains at all 

poles the electronics cover is opened.

The fuse is in the power electronics (14) beneath the electron-

ics cover.

This fine wire fuse must always be replaced with a fuse of the 

same type: 10 A, quick-acting, interrupting capacity “H”.

F 10 A

14

Figure 6

Содержание Combi 2 E

Страница 1: ...EN Operating instructions To be kept in the vehicle Combi E Page 02 ...

Страница 2: ...al 10 Faults 11 Troubleshooting guide water supply 11 Accessories 11 Manufacturer s Warranty European Union 12 Combi E Geändert Ludsteck 2017 17 18 2 3 5 7 8 9 11 10 14 15 16 4 12 13 6 6 1 Figure 1 Symbols used Symbol indicates possible hazards Note containing information and tips Observe the ESD regulations Intended use Proper use The appliance is approved solely for installation and opera tion i...

Страница 3: ... smoke Open windows and doors Evacuate all persons from the vehicle Shut off gas cylinders and or shut off the gas supply from the outside Have the entire gas system inspected and repaired by experts Do not put the gas system back into opera tion until it has been inspected and repaired Working on the appliance in the installation compartment Possible danger from electric shock or explosion as a r...

Страница 4: ... relevant national regulations in Germany every 2 years The test must be confirmed on the respective test certificate G 607 Pressure regulating devices and hoses must be replaced with new ones no more than 10 years after their date of manufacture every 8 years if used commercially Inspect hose lines regularly and have them replaced if they are broken Safe operation The exhaust cowl must not be blo...

Страница 5: ...le duct must be checked regularly particu larly at the end of long trips Also check the mounting of the appliance and the cowl Operation while driving For heating while driving the directive UN ECE R 122 for motor caravans and cara vans specifies a safety shut off device in order to prevent the uncontrolled escape of gas in the event of an accident The Truma MonoControl CS gas pressure regulator s...

Страница 6: ...red this is possible in hot water mode In hot water mode the water is heated at the lowest burner setting Once the water temperature has been reached the burner switches off In heating mode the appliance automatically selects the required operating level according to the temperature dif ference between the temperature set on the control panel and the current room temperature If the boiler has been...

Страница 7: ...nage socket led outside through floor of vehicle Operating instructions Heating mode In heating mode the appliance automatically selects the required operating level according to the temperature differ ence between the temperature set on the control panel and the current room temperature If the water container has been filled the water is automatically heated as well The water temperature depends ...

Страница 8: ...al position a or b Filling the water Check whether the safety drain valve is closed see Closing the safety drain valve When the temperature at FrostControl is below approx 7 C first switch on the heater to warm the installation compartment and FrostControl After several minutes when the temperature at FrostControl is above 7 C the safety drain valve can be closed Switch on the power for the pump a...

Страница 9: ...on for at least 30 minutes and no hot water may be removed The residual heat in the heat exchanger will heat the water up to 70 C Solar systems When a solar system is used EN 1648 stipulates that a battery with charge regulator or a voltage regulator output voltage 11 V 15 V alternating voltage ripple 1 2 Vss must be connected between the solar system and the heater at all times Otherwise the heat...

Страница 10: ...s consumption Combi 2 E UK 160 g h Combi 4 E 160 335 g h Combi 6 E 160 460 g h Standby heat requirement all appliances Gas mode 8 6 g h measured in accordance with EN 15033 Additional information according to EN 624 Combi 2 E UK Qn 2 4 kW Hs 170 g h C13 I3 B P 30 Combi 4 E Qn 4 8 kW Hs 345 g h C13 I3 B P 30 Combi 6 E Qn 6 8 kW Hs 480 g h C13 I3 B P 30 Destination countries Combi 2 E UK GB IE Combi...

Страница 11: ...ent for FrostControl The FrostControl can no longer be closed Temperature at FrostControl less than approx 7 C Switch heater on Without heater operation the FrostControl cannot be closed again until the temperature reaches ap prox 7 C Rotary switch is not set to Operation Turn the rotary switch of the FrostControl to Operation then press the pushbutton until it engages If these actions do not reme...

Страница 12: ...2 Warranty exclusions No warranty claim shall be applicable under the following circumstances Improper unsuitable faulty or negligent use and any use that is not compliant with the intended purpose Improper installation assembly or commissioning contrary to operating or installation instructions Improper operation or operation contrary to operating or installation instructions particularly any dis...

Страница 13: ...89 4617 2020 Telefax 49 0 89 4617 2159 service truma com www truma com EN Should problems occur please contact the Truma Service Centre or one of our authorised service partners see www truma com In order to avoid delays please have the unit model and serial number ready see type plate 34020 00851 00 11 2019 ...

Отзывы: