25
Installation
Remove the equipment pack (accessories) and check it is
complete:
1 instructions for installation and use
1 connection cable 230 V, 1 m
1 fuse 30 A
1 fuse holder
4 mounting screws
4 washers
4 cable shoes
2 snap ferrites
The device should be installed away from damp and wet. The
installation site should be clean, dry and well ventilated. Dur-
ing operation, the casing can heat up to around 75 °C. There-
fore observe a minimum clearance of 100 mm and ensure that
the ventilation slits are not covered.
The designated room in which the device is to be installed
may not undercut the following dimensions as a minimum
clearance of 100 mm all-round must be observed.
Length: 420 mm / Width: 410 mm / Height: 190 mm
The installation space for the device must have ventilation
openings at the top and side that provide a total opening
surface of 100 cm².
Liquid electrolyte batteries need to be placed in a separate
box with ventilation directed to the outside. The gel and AGM
batteries do not need a separate box. Observe the installation
regulations of the battery manufacturer.
Securely attach the device using the 4 supplied mounting
screws.
Installation instructions
Safety instructions
This device contains parts that could cause sparks or a
light arc!
The device must be connected to the mains power supply
in accordance with the respective valid national installation
regulations.
Only qualified technicians may assemble and connect electri-
cal devices!
Ensure that the power supply has been disconnected! Discon-
nect the mains plug!
Only use the supplied parts and the specified cable cross-sec-
tions and fuses to connect the device!
Only use suitable and fully functional tools.
Only wire the device as specified in the supplied wiring
diagram!