5
Selecting a location
Once the roof-mounted air conditioning system has
been installed, any nearby exhaust cowl must extend
at least 10 cm above the air conditioning system. The exhaust
cowl must be extended if necessary (pay attention to the
heater manufacturer’s specifications).
The roof of the vehicle (roof thicknesses of 25 to 110 mm)
must be level and smooth.
Three installation options are available:
– The cut-out must be a new cut-out (350 x 380 mm)
– Cut-out of an existing roof hatch (400 x 400 mm)
without
a
sealing frame (accessory).
– Cut-out of an existing roof hatch (400 x 400 mm)
with
a
sealing frame (accessory). The installation instructions are
included with the sealing frame.
Attention must always be paid to the following points:
– The appliance should be installed as close as possible to the
centre of the vehicle.
– Check that no obstructions are present that will hinder
installation.
– There may be electrical cables running between the interior
and the exterior of the roof. Disconnect all voltage sources
before starting the work (all poles).
– The roof load must not be exceeded (see vehicle manufac-
turer’s specifications).
– Check the interior installation site for obstructions.
– A wooden reinforcing frame (min. 25 mm) must be installed
around the roof cut-out between the upper and lower sur-
faces of the roof. The insulation may have to be removed.
When the skylight with safety ventilation is replaced by
the air conditioning system, it must be ensured that the
safety ventilation is restored in another suitable location.
Control panel cable
To simplify
subsequent
installation of BUS appliances, feed
the control panel cable that is supplied in the accessory kit
together with the mains cable through the false ceiling.
Fix the free end of the control panel cable to a suitable place,
such as in a wardrobe, as a connection point.
Cut-out installation 400 x 400
For optimum sealing we recommend the use of the sealing
frame that is available as accessory (part no. 40091-19000).
For installation with a sealing frame, please refer to the instal-
lation instructions provided with the sealing frame.
Installation of the appliance
with
an existing roof hatch:
the cut-out must be 400 x 400 mm.
Remove existing roof hatch (make cut-out bigger if necessary).
Remove sealant residue and unevenness.
Fill in screw holes with body sealant.
400
40
0
Fig. 13
For the other installation steps, please refer to “Preparation
for power cable connection and control panel cable”.
Installation with new cut-out
For vehicles without an existing cut-out:
required cut-out 350 x 380 mm.
Place template on installation location on vehicle, mark cut-
out (350 x 380 mm) and cut it out.
Mark the 4 holes (10 mm) for bracket attachment and drill
holes in the roof.
380
35
0
Fig. 14