background image

6

IR receiver and manual on / off

There is an additional pushbutton on the receiver (m), with 
which the unit can also be switched on and off without the 
remote control (e.g. with a ballpoint pen).

If the unit is switched on using this pushbutton, the system is 
automatically reset to the factory settings (Automatic mode, 
22 °C).

IR receiver / operating indicator

LED 3

LED 2

LED 1

m

LED 1 blue – permanently on – (cooling mode)
LED 1 blue – flashing – (cooling mode compressor start-up) 

LED 2 yellow – permanently on – (heating mode)
LED 2 yellow – flashing – (heating mode compressor start-up)

LED 3 red – flashing – (data is being transmitted)
LED 3 red – permanently on – (fault)

Red LED illuminates

The unit is indicating a fault. Switch unit off, wait for a short 
time and switch on again. If the red LED continues to illumi-
nate, please contact Truma Service.

Air distribution

Right / left

Two individually adjustable air outlets at the front, and two at 
the rear.

Front / rear

The air flow can be split so that specific quantities are fed into 
the front and rear areas of the vehicle.

Ceiling / floor

The air flow can be deflected from the ceiling to the floor.

right / left

right / left

right / left

right / left

IR receiver /
operating indicator

front / rear

ceiling / 
floor

ceiling / 
floor

fr

ont 

fr

ont 

rear

rear

Changing the battery in the IR remote control

Please be sure to use leak-proof micro-batteries only, 
type LR 3, AM4, AAA, MN 2400 (1.5 V). 

The battery compartment is located on the rear of the remote 
control unit.

When fitting new batteries, ensure the 
polarity (positive/negative) is correct!

Dead and used batteries may leak 
and damage the remote control 

unit. Remove the batteries if the remote 
control is not going to be used for an ex-
tended period.

No claims under guarantee will be considered for dam-
age caused by leaking batteries.

Before throwing away a defective remote control, it is es-
sential that the batteries be removed and disposed of in the 
proper manner.

Maintenance

Filter changes should be carried out depending on the 
amount of use, but we recommend a change at least every 
12 months. Never operate the air conditioning system without 
a filter, since this can decrease performance. Always keep the 
air inlets / air outlets and condensation traps on the roof free 
from obstructions such as leaves. Use a soft, clean cloth to 
clean the air conditioning system.

Disposal

The device must be disposed of in line with the administra-
tive regulations of the respective country in which it is used. 
National regulations and laws (in Germany, for example, the 
End-of-life Vehicle Regulation) must be observed.

In other countries, the relevant regulations must be observed.

Содержание Aventa comfort

Страница 1: ...Aventa comfort Australia Operation instructions Page 2 Installation instructions Page 9 To be kept in the vehicle ...

Страница 2: ...intenance 6 Disposal 6 Accessories 7 Troubleshooting 7 Technical data 7 Installation dimensions dimensions in mm 7 Clearance around the air conditioning system 8 Air inlets Air outlets 8 Condensation traps 8 Declaration of conformity 8 Truma warranty policy 9 Installation instructions Scope of delivery 9 Intended use 9 Location selection 9 Installation in a 400 x 400 cut out 10 Installation in a n...

Страница 3: ...scenario might penetrate into the vehicle For problem free operation and in order to avoid damage the supply voltage must always come from a source with a sine wave curve e g voltage converter generator and without voltage spikes When the vehicle is being cleaned with a high pressure cleaner for example make sure that no water can get in to the unit do not spray directly into the openings of the u...

Страница 4: ...rating mode selection button Cooling Heating Automatic Circulated air Temperature selection buttons 16 31 C In 1 C increments On off switch Reset Restores the remote control to its factory settings Fan level Low Medium not heating mode High Resend Retransmit data Clock time selection button Time setting Setting for clock time and timer Timer selection buttons Switch on or switch off time can be se...

Страница 5: ...lly depending on the room temperature when the unit is in automatic mode In recirculated air mode the interior air is circulated and cleaned by the filters No LED s illuminate on the IR receiver Fan Select the required fan level by pressing the Fan level but ton one or more times Fan level not operational in automatic mode Low Medium not heating mode High Sleep function When the Sleep function is ...

Страница 6: ...g floor ceiling floor front front rear rear Changing the battery in the IR remote control Please be sure to use leak proof micro batteries only type LR 3 AM4 AAA MN 2400 1 5 V The battery compartment is located on the rear of the remote control unit When fitting new batteries ensure the polarity positive negative is correct Dead and used batteries may leak and damage the remote control unit Remove...

Страница 7: ... outs measuring 400 x 400 mm Troubleshooting Fault Cause Action Unit not cooling Thawing process in progress The temperature set on the re mote control has been reached or is too high Unit not heating Thawing process in progress outside temperature between 4 C and 7 C Outside temperature below 4 C Unit underperforming or failing in cooling heating mode Filter soiled replace filter Air ways to the ...

Страница 8: ...EN62233 EN55014 2 IEC EN60335 1 IEC EN60335 2 40 2009 19 EC DIN EN378 2 5 Information and the function of the signatory Signature Dr Schmoll Managing Director Engineering Putzbrunn 18 02 2011 Clearance around the air conditioning system The clearances around the external unit must be 20 mm at the front 100 mm to the side and as far as possible and not less than 200 mm to the rear 1 0 0 6 6 0 1 0 0...

Страница 9: ...Expenses Cleaning of the system This is considered to be a part of normal product maintenance Non operation of the appliance or resultant damage to the unit where the appliance has been operated in an out of level situation Freight cost of the appliance or parts to or from point of service or transit damage Dometic Truma are not responsible for resultant loss or damage sustained by the purchaser N...

Страница 10: ...drill through the roof 380 3 5 0 Preparation for mains cable connection A leadthrough for the mains cable to the connection point should be provided in the intermediate ceiling for example Lift the unit onto the roof holding it in a horizontal position and insert it into the cut out The arrow points in the vehicle s direction of travel If the unit has been turned over or was not horizontal at all ...

Страница 11: ... be made by an expert in accordance with VDE 0100 part 721 or IEC 60364 7 721 for example in Germany The information given here is not intended as instructions for you to carry out It is for assisting the expert assigned to carry out the job act ing as auxiliary information when connecting the appliance Connect the power supply cable that has been routed to the connecting point All cables must be ...

Страница 12: ...d the serial number ready see type plate will speed up processing 40091 39400 01 06 2011 Fo Service Australia Telephone 61 0 3 92 39 10 00 Facsimile 61 0 3 92 39 10 99 Dometic Pty Ltd Building 3B Clayton Business Park 1508 Centre Road Clayton Victoria 3168 Australia Dometic New Zealand Ltd 26 Cashew Street Grenada North Wellington New Zealand Service New Zealand Telephone 64 0 4 232 38 98 Facsimil...