Taking into operation

Before switching on, it is essential to make sure that the fuse 
system for the power supply at the camp site is sufficient 
(230 V).

In order to prevent the power cable for the caravan from 
overheating (minimum cross-section 3 x 2.5 mm²) the 

cable drum must be fully unwound.

To carry out the individual switching commands, the remote 
control must always be pointed at the infrared receiver.

Switching on

Press the 

“On/Off switch”

 on the remote control to switch 

on the air conditioning unit. The most recent settings are 
applied.

After switching on, the air circulation fan starts to run. 
The compressor activates after a maximum of 3 minutes, 

and the blue (cooling) / yellow (heating) LED flashes.

Temperature

If required, adjust the room temperature setting using the 

“+”

 

and 

“–”

 

“Temperature selection buttons”.

Mode

Select the required operating mode by pressing the 

“MODE”

 

button one or more times.

Cooling
Heating
Automatic (heating or cooling mode depending on the room 
temperature setting)
Circulated air

When the room temperature that was selected using the 
remote remote control is reached in 

cooling mode,

 the com-

pressor switches off and the blue LED in the IR receiver goes 
out. The air circulation fan continues to run in order to provide 
ventilation. If the room temperature setting is exceeded, the 
device automatically reverts to cooling mode. 

When the room temperature that was selected using the 
remote remote control is reached in 

heating mode,

 the com-

pressor switches off and the yellow LED in the IR receiver goes 
out. The air circulation fan continues to run in order to provide 
ventilation. If the temperature drops below the room tempera-
ture setting, the device automatically reverts to heating mode.

Heating is not possible at an outside temperature of 
less than 4 °C, as the heating power drops significantly. 

Between 4 °C and 7 °C the device briefly switches to thawing 
processes. Heating is possible without restrictions above 7 °C.

Cooling/heating mode and the fan level are selected automati-
cally depending on the room temperature when the unit is in 

automatic mode.

In 

recirculated air mode,

 the interior air is circulated and 

cleaned by the filters. No LED‘s illuminate on the IR receiver.

Fan

Select the required fan level by pressing the 

“Fan level”

 but-

ton one or more times.

Fan level

 (not operational in automatic mode)

Low
Medium (not heating mode)
High






Sleep function

When the 

“Sleep function”

 is active (cooling mode only), 

the interior fan and the exterior fan operate at slow speed and 
therefore extremely quietly.

Switching off

Press the 

“On / Off”

 button on the remote control to switch 

the equipment off. The remote control and the unit are 
switched off. The light can still be operated using the 

“Ambient lighting”

 button.

If the air conditioning unit is switched on again, the blue / 
yellow LED flashes. The air circulation fan runs and the 

compressor switches itself on after a maximum of 3 minutes. 

Time

Press the 

“Time selection button”

 and set the current time 

using the “Time setting” buttons.

The time is always shown in the display (except with Timer 
ON / OFF).

The time must be reset after a battery change or daylight sav-
ing time change.

Timer ON / OFF

The air conditioning unit on/off time can be set in advance 
from a minimum of 15 minutes up to a maximum 24 hours, 
starting from the current time.

To carry out programming, switch on the unit with the remote 
control.

Set the required operating mode and room temperature.

Then select TIMER ON or TIMER OFF using the 

“TIMER 

selection buttons”.

 Set the required on/off time using the 

“Time setting”

 buttons (15 minutes – 24 hours) and 

confirm

 

with TIMER ON or TIMER OFF.

Press the relevant timer button again to deactivate the timer 
function.

Ambient lighting

Independently of the operation of the air conditioning system, 
the lighting in the air distributor can be switched on and off 
by pressing the 

„Ambient lighting“

 button. To dim the light-

ing, press and hold down the 

“Ambient lighting”

 button. 

Press the button again to activate or deactivate the lighting. 
When the lighting is switched on again, the previous setting is 
activated.

Reset

The settings on the remote control are reset to “AUTO, 22 °C, 
12:00, No timer, No light”.

Resend

The most recent settings are transmitted again.

Содержание Aventa comfort

Страница 1: ...Aventa comfort Australia Operation instructions Page 2 Installation instructions Page 9 To be kept in the vehicle ...

Страница 2: ...intenance 6 Disposal 6 Accessories 7 Troubleshooting 7 Technical data 7 Installation dimensions dimensions in mm 7 Clearance around the air conditioning system 8 Air inlets Air outlets 8 Condensation traps 8 Declaration of conformity 8 Truma warranty policy 9 Installation instructions Scope of delivery 9 Intended use 9 Location selection 9 Installation in a 400 x 400 cut out 10 Installation in a n...

Страница 3: ...scenario might penetrate into the vehicle For problem free operation and in order to avoid damage the supply voltage must always come from a source with a sine wave curve e g voltage converter generator and without voltage spikes When the vehicle is being cleaned with a high pressure cleaner for example make sure that no water can get in to the unit do not spray directly into the openings of the u...

Страница 4: ...rating mode selection button Cooling Heating Automatic Circulated air Temperature selection buttons 16 31 C In 1 C increments On off switch Reset Restores the remote control to its factory settings Fan level Low Medium not heating mode High Resend Retransmit data Clock time selection button Time setting Setting for clock time and timer Timer selection buttons Switch on or switch off time can be se...

Страница 5: ...lly depending on the room temperature when the unit is in automatic mode In recirculated air mode the interior air is circulated and cleaned by the filters No LED s illuminate on the IR receiver Fan Select the required fan level by pressing the Fan level but ton one or more times Fan level not operational in automatic mode Low Medium not heating mode High Sleep function When the Sleep function is ...

Страница 6: ...g floor ceiling floor front front rear rear Changing the battery in the IR remote control Please be sure to use leak proof micro batteries only type LR 3 AM4 AAA MN 2400 1 5 V The battery compartment is located on the rear of the remote control unit When fitting new batteries ensure the polarity positive negative is correct Dead and used batteries may leak and damage the remote control unit Remove...

Страница 7: ... outs measuring 400 x 400 mm Troubleshooting Fault Cause Action Unit not cooling Thawing process in progress The temperature set on the re mote control has been reached or is too high Unit not heating Thawing process in progress outside temperature between 4 C and 7 C Outside temperature below 4 C Unit underperforming or failing in cooling heating mode Filter soiled replace filter Air ways to the ...

Страница 8: ...EN62233 EN55014 2 IEC EN60335 1 IEC EN60335 2 40 2009 19 EC DIN EN378 2 5 Information and the function of the signatory Signature Dr Schmoll Managing Director Engineering Putzbrunn 18 02 2011 Clearance around the air conditioning system The clearances around the external unit must be 20 mm at the front 100 mm to the side and as far as possible and not less than 200 mm to the rear 1 0 0 6 6 0 1 0 0...

Страница 9: ...Expenses Cleaning of the system This is considered to be a part of normal product maintenance Non operation of the appliance or resultant damage to the unit where the appliance has been operated in an out of level situation Freight cost of the appliance or parts to or from point of service or transit damage Dometic Truma are not responsible for resultant loss or damage sustained by the purchaser N...

Страница 10: ...drill through the roof 380 3 5 0 Preparation for mains cable connection A leadthrough for the mains cable to the connection point should be provided in the intermediate ceiling for example Lift the unit onto the roof holding it in a horizontal position and insert it into the cut out The arrow points in the vehicle s direction of travel If the unit has been turned over or was not horizontal at all ...

Страница 11: ... be made by an expert in accordance with VDE 0100 part 721 or IEC 60364 7 721 for example in Germany The information given here is not intended as instructions for you to carry out It is for assisting the expert assigned to carry out the job act ing as auxiliary information when connecting the appliance Connect the power supply cable that has been routed to the connecting point All cables must be ...

Страница 12: ...d the serial number ready see type plate will speed up processing 40091 39400 01 06 2011 Fo Service Australia Telephone 61 0 3 92 39 10 00 Facsimile 61 0 3 92 39 10 99 Dometic Pty Ltd Building 3B Clayton Business Park 1508 Centre Road Clayton Victoria 3168 Australia Dometic New Zealand Ltd 26 Cashew Street Grenada North Wellington New Zealand Service New Zealand Telephone 64 0 4 232 38 98 Facsimil...

Отзывы: