background image

-12-

Note :

The TBG-460GC Monitoring System includes glucose and 

    total cholesterol test that are all plasma calibrated. The user does 
    not have to convert it into plasma result.
2. Use the strips before the 

 date, the strips can only be used 

    within 3 months remaining shelf life after the first opening of the
    vial.
3. Apply the blood sample onto the correct position of the strip 
    precisely, follow the directions to 
4. Prohibited applying the blood sample to the test strip twice, it will 
    cause inaccurate test results.        

1. 

expiry

avoid incorrect operations.

3.6 Care after the Test

Directions:
1. Improper usage of the meter, such as dropping, bumping or other 
    violent impact may cause the meter damaged.
2. Please keep meter away by interferences of magnetic, 
    electromagnetic, and radioactive.  

Warning :

Do not disassemble the meter for any reason.

2. Please follow local regulations to discard used test strips 
    and lancets.
3. Used test strips, lancets and any other materials that have
    come in contact with blood should be treated as potential 
    biohazards. If a user has an infectious disease, used test 
    strips and other materials could be a sources of infection.  

1. 

3.5 Special messages

Mode                                          Lo                                             Hi
Glucose                 < 20 mg/dL  (1.11 mmol/L)     > 600 mg/dL (33.3 mmol/L)
Total Cholesterol   < 100 mg/dL  (2.59 mmol/L)   > 400 mg/dL  (10.35 mmol/L)

Содержание TBG-460

Страница 1: ...Blood Glucose Cholesterol 2 in 1 Monitoring System User s Manual 2015 07 14 Rev 01 www trulyinstrument com Model TBG 460GC...

Страница 2: ...Testing 3 2 Connect iOS device via Bluetooth 3 3 Perform the Blood Glucose Test 3 5 Special messages 3 6 Care after the test Chapter 4 Chapter 5 Meter Memory Function Chapter 6 Installing Replacing th...

Страница 3: ...ugh the operation procedures with illustrated directions and help you find the required informations Please contact the local distributor for questions and enquiries WARNING Please carefully read the...

Страница 4: ...t Hct above 55 may cause reduced glucose results versus a whole blood reference Do not drop the product Keep the lancets and lancing device out of the reach of the children o Keep the meter and test s...

Страница 5: ...companying documents Storage temperature limitation Use by EU Representative Catalogue number Product number Manufactured by 0123 1 5 System Components Test Strip Port Insert test strip here The meter...

Страница 6: ...At least 10uL of blood sample is essential Reaction Zone Reaction zone of Total Cholesterol CHOL Glucose Test Strip Blue Color Sample Inlet The inlet where the whole blood or control solution is drawn...

Страница 7: ...s are listed as follows Set the Year 1 When the meter enter setting mode the first item on the screen such as 2012 will blink on screen which means Year 2 Press the up down button to 3 After you set t...

Страница 8: ...wm button until the correct measurement unit appears 2 Press the memory button will show OFF on the screen and power off Chapter 3 How to perform Test 3 1 Before Testing 7 Coding the Meter TRULY TRULY...

Страница 9: ...so the same as marked on the test vial Remove the code strip should appear on the screen indicating that the meter has been successfully coded Cautions If E E appears on the screen during coding proce...

Страница 10: ...napping it back onto the lancing device body 4 Select the skin penetration depth by turning the depth selector until the desired number can be seen in the selection window 5 levels of skin penetration...

Страница 11: ...Be careful to make sure the marked re code test mode and code number on the screen are the same as the one on the test strip vial Icon GLUC and CHOL indicate measuring mode of glucose and total chole...

Страница 12: ...wn from 26 seconds for cholesterol testing 3 4 Perform the Total Cholesterol Test 11 4 Touch the sample Inlet of the strip to the drop of blood sample until the meter sounds a beep which means the sam...

Страница 13: ...s 3 6 Care after the Test Directions 1 Improper usage of the meter such as dropping bumping or other violent impact may cause the meter damaged 2 Please keep meter away by interferences of magnetic el...

Страница 14: ...o keep the strips in dry condition 2 Be careful to make sure the test mode and code number on the screen are the same as the one marked on the test strip vial If not remove the test strip and re code...

Страница 15: ...est mode only total cholesterol test mode do not have the day average function Chapter 5 Meter Memory Function Please read this user s manual for control solution test carefully before use Do not reus...

Страница 16: ...l hear a beep sound which indicates that meter is 3 Place back the cover onto the meter ready 5 After the 28day average the latest stored result M01 appears on the screen Then you can read the stored...

Страница 17: ...bent hole Revlew the instructiona and try again with a new test strip If the problem persists please contact the dealer for service E 9 Chapter 7 Storage and Handling of Meter and Strips Due to sensit...

Страница 18: ...ter and the test strip have reached at temperature within the operating range E U It could be caused by a used test strip or a temporary or permanent electronic problem Repeat the test with a new test...

Страница 19: ...se level 75 mg dL 4 17mmol L 20 at Total Cholesterol 150mg dL 3 88mmol L Electrochemical Biosensor Plasma equivalent Glucose 20 600 mg dL 1 1 33 3 mmol L Total Cholesterol 100 400 mg dL 2 59 10 35 mmo...

Страница 20: ...radio frequency energy However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or reception which can be...

Страница 21: ...Knitting Centre 1 3 Wing Yip St Kwai Chung N T HONG KONG Tel 852 2487 9803 Fax 852 2146 5756 Http www trulyinstrument com EC Representative Wellkang Ltd t a Wellkang Tech Consulting Suite B 29 Harley...

Отзывы: