background image

TRUE RESIDENTIAL

®

TEC_TM_073 | REV. D | EN

12/03/2021

Page 24 of 56

CUS TOM PANEL INS TALL ATION

Required Tools:

 Phillips Screwdriver

 3/8" Wrench 

 1/8" Drill Bit

 Three (3) Screws #6

SEE PAGE 16 FOR OVERLAY PANEL DIMENSIONS 
BEFORE INSTALLING.

FOR EASY OVERLAY INSTALLATION, ICE MACHINE 
DOOR REMOVAL IS REQUIRED.

1.   Open front door and pull kickplate forward  

to remove.

2.   To remove door, back out two bottom hinge 

screws with a 3/8" wrench. Secure door while 
removing screws. Remove two Phillips screws 
from the top hinge. Save all these screws for later 
reinstall.

3.   Lay door on a safe solid surface. Lay cardboard  

or other safe material down before working on  
the door.

4.   Remove door gasket from the inside of the door 

frame. Place gasket to the side for later reinstall.

5.   There are pre-marked areas on the front of the 

door. Drill these pre-marked holes with 1/8" drill 
bit. Make sure to drill all the way through the 
door.

NOTE: IF HANDLE IS BEING USED ON OV ERL AY, 
INSTA LL IT BEFORE STEP 8 (SEE IMAGE A ON 
PAGE 22). FOR BEST INSTA LL ATION, SCREWS 
AT TACHING HANDLE SHOULD BE RECESSED. 

6.   It is recommended to clamp the door front on 

top of the overlay before drilling pilot holes and 
installing anchor screws. The clamp ensures the 
overlay panel and door stay aligned with each 
other while installing. Once panel is clamped in 
place, pilot holes may be drilled into the panel 
from the rear side of the door. Mark to only drill 
1/2" into rear side of door.

1

3 & 4

2

Remove screws 

from top and 

bottom hinge

6

5

Содержание TUI-15-R/L-OP-B

Страница 1: ...15 INCH TRUE ICETM MACHINE INSTALL GUIDE TEC_TM_073 REV D EN 12 03 2021 Page 1 of 56 TRUE RESIDENTIAL 15 INCH CLEAR ICE MACHINE INSTALL GUIDE AND USER S MANUAL P R E S E R V E T H E M O M E N T...

Страница 2: ...TRUE RESIDENTIAL TEC_TM_073 REV D EN 12 03 2021 Page 2 of 56...

Страница 3: ...ign inspiration or product information For 70 years we ve been pioneers in cold but we ve also been leaders in warm customer service and support We hope that this guide offers you what you need for th...

Страница 4: ...TRUE RESIDENTIAL TEC_TM_073 REV D EN 12 03 2021 Page 4 of 56 P R E S E R V E T H E M O M E N T L U X U R Y R E F R I G E R A T I O N W I T H C O M M E R C I A L D N A...

Страница 5: ...27 DRAIN CONNECTION 28 WATER FILTER 29 POSITION THE UNIT 29 PUMPING HEIGHTS 30 31 DRAIN ALARM DRN 32 TRUE PRECISION CONTROL OPERATION AND TRUE ICE MACHINE COMPONENTS 34 36 BEFORE OPERATING 37 ICE MAKI...

Страница 6: ...TRUE RESIDENTIAL TEC_TM_073 REV D EN 12 03 2021 Page 6 of 56 NOTES...

Страница 7: ...ions been made Has the ice machine drain line been routed into an open drain with no more than 7 2 13 m of rise and 100 feet 33 m of run Is the unit leveled properly with all leveling legs making cont...

Страница 8: ...TRUE RESIDENTIAL TEC_TM_073 REV D EN 12 03 2021 Page 8 of 56 NOTES...

Страница 9: ...L I D P A N E L R E A D Y D O O R O P S O L I D P A N E L R E A D Y D O O R O P 15 INCH TRUETM ICE MACHINE TUI 15 R L OP B 15 INCH OVERLAY PANEL S TA I N L E S S S T E E L D O O R S S S TA I N L E S S...

Страница 10: ...TRUE RESIDENTIAL TEC_TM_073 REV D EN 12 03 2021 Page 10 of 56 NOTES...

Страница 11: ...of 56 F E AT U R E S O F T H E I C E M A C H I N E O W N E R S H I P S A F E T Y P R E C A U T I O N S P R O P E R D I S P O S A L A N D C F C D I S P O S A L W A R N I N G S A F E T Y L A B E L S U N...

Страница 12: ...stallation please contact your True dealer or True Technical Service Department at 844 746 9423 Please have your model and serial numbers available when you call our Service Department SAFETY PRECAUTI...

Страница 13: ...e believed to harm stratospheric ozone If you are throwing away your old ice machines make sure the CFC refrigerant is removed for proper disposal by a qualified service If you intentionally release t...

Страница 14: ...oden skid A Remove staples securing cardboard box to the wooden skid Then discard any outer packaging cardboard clear plastic Cut off all strapping B IMPORTANT Remove Styrofoam block before removing i...

Страница 15: ...rloading house wiring circuits which could cause a fire hazard from overheated wires Never unplug your ice machine by pulling on the power cord Always grip plug firmly and pull straight out from the o...

Страница 16: ...TRUE RESIDENTIAL TEC_TM_073 REV D EN 12 03 2021 Page 16 of 56 NOTES...

Страница 17: ...TA L L AT I O N S P E C I F I C AT I O N S F O R S O L I D P A N E L A N D I N T E G R AT E D P A N E L O P I N S TA L L I N G D O O R S T O P P L U M B I N G C O N N E C T I O N S L E V E L I N G I C...

Страница 18: ...VIEW FRONT VIEW ICE MACHINE TUI 15 R L SS B 237 8 11 2 147 8 341 4 377 8 161 4 30 311 16 43 16 Dimensions may vary by 1 8 253 4 SURROUNDING CABINETRY SURROUNDING CABINETRY 15 INCH STAINLESS STEEL TOP...

Страница 19: ...ing Below are recommended minimum dimensions for rough opening Avoid running wires or plumbing in this area SURROUNDING CABINETRY SURROUNDING CABINETRY 9 16 111 2 FRONT VIEW OF CABINETRY OPENING BACKV...

Страница 20: ...UNIT IS SHOWN WITH OPTIONAL PANEL HANDLE PROVIDED BY OTHERS TOPVIEW OF ICE MACHINE SIDEVIEW OF ICE MACHINE FRONT VIEW OF ICE MACHINE 237 8 3 4 231 8 147 8 341 4 161 4 293 4 33 4 41 8 215 8 SURROUNDIN...

Страница 21: ...cabinetry Two specification options for panels sizes are given in these instructions for overlay units Standard overlays and Integrated Panels The standard overlay panel dimensions fully cover the pr...

Страница 22: ...or Panel Height 29 23 32 Door Panel Depth 3 4 max Door Panel Weight 10 lb max SIDE VIEW 237 8 3 4 231 8 341 4 33 4 41 8 11 2 CUSTOM PANEL INSTALLATION SOLID PANEL PANEL Including 3 4 thick panel provi...

Страница 23: ...HT 30 1 8 DOOR PANEL DEPTH 3 4 max DOOR PANEL WEIGHT 20 lb max RAIL STYLE DIMENSION 2 min 30 1 8 14 5 8 3 4 A 5 8 9 16 DETAIL A SCALE 1 1 1 DET SCAL 30 1 8 14 5 8 3 4 A 5 8 9 16 DETAIL A SCALE 1 1 1 D...

Страница 24: ...n the door 4 Remove door gasket from the inside of the door frame Place gasket to the side for later reinstall 5 There are pre marked areas on the front of the door Drill these pre marked holes with 1...

Страница 25: ...LAY PANEL 8 CUSTOM PANEL INSTALLATION 7 Once all holes are pre drilled use the appropriate specified screws to secure the overlay panel onto the front of the ice machine door Be sure to attach the bot...

Страница 26: ...cabinetry To install the door stop use the two screws provided and secure the bracket to the bottom of the door on the same side as the hinge PLUMBING CONNECTIONS The ice machine must be installed wi...

Страница 27: ...to the house supply with an easily accessible shut off valve between the water supply and the ice machine A reverse osmosis system can be used provided there is constant water pressure of 20 psi 1 4...

Страница 28: ...t drain configurations Fitting 1 3 8 to 3 8 union adapter CAUTION FOR CONNECTION TO WORK AS DESIGNED TUBING SHOULD BE CUT AT PERFECT 90 DEGREE ANGLE BEFORE INSTALLING ON UNION ADAPTER Fitting 2 3 8 O...

Страница 29: ...s are available through your True dealer or online store at www true residential com CAUTION INSTALL THE WATER FILTER BEFORE TURNING ON THE WATER SUPPLY TO THE ICE MACHINE CAUTION DO NOT ALLOW THE ICE...

Страница 30: ...TRUE RESIDENTIAL TEC_TM_073 REV D EN 12 03 2021 Page 30 of 56 84 7FT MAX STANDARD PUMP WITH 3 8 O D HOSE PUMPING HEIGHTS...

Страница 31: ...TM_073 REV D EN 12 03 2021 Page 31 of 56 STANDARD PUMP WITH 3 8 O D HOSE TO 5 8 O D HOSE 3 8 O D HOSE Provided 3 8 union adapter Provided 3 8 push to 1 2 I D barb Provided 5 8 O D HOSE Not provided ST...

Страница 32: ...t of a drain failure If a clogged drain clears the display will read DRN OFF CAUTION ADHERE TO LOCAL AND STATE PLUMBING CODES DO NOT EXCEED THE MAXIMUM PLUMBING HEIGHTS FOR THE GIVEN SETUP THE DRAIN A...

Страница 33: ...P E R AT I O N A N D T R U E I C E M A C H I N E C O M P O N E N T S B E F O R E O P E R AT I N G P O W E R A N D B I N L I G H T I C E M A K I N G S E Q U E N C E A N D C U B E S I Z E A D J U S T M...

Страница 34: ...s Harvesting Ice Water will fill for the next batch of ice and drop the ice in the molds Fill Water is filling the reservoir and will run for 2 3 minutes Bin is Full Ice has reached the bar located on...

Страница 35: ...r quality setting Adds time to harvest Filter change reminder set at 6 months Drain Pump Failure Clogged or kinked drain line Drain was not able to clear within 5 minutes of running Thermistor 1 Failu...

Страница 36: ...r Button 2 Bin Light 3 Initiate Cleaning Sequence 4 Adjust Cube Size 5 Display 1 2 3 4 5 KEY COMBINATIONS LCD READOUTS DESCRIPTION Ambient too Cold Condenser discharge thermistor reached 50 F System t...

Страница 37: ...always begins in the harvest mode Display will read HAr During harvest all the ice cubes are melted free from the evaporator The ice machine does this by warming up the evaporator with warm refrigera...

Страница 38: ...will show drn and cut power to the unit If unit is too cold below 50 F too hot or if the temperature probe is unplugged or has failed the unit shuts down and displays an error message BIN LIGHT Use th...

Страница 39: ...CE LEVEL Turn adjustment clockwise to raise ice level LOWER ICE LEVEL Turn adjustment counter clockwise to lower ice level BREAKER RESET The breaker switch is located behind the kickplate If the unit...

Страница 40: ...TRUE RESIDENTIAL TEC_TM_073 REV D EN 12 03 2021 Page 40 of 56 NOTES...

Страница 41: ...T C A P D I S A S S E M B LY P O S I T I O N I N G W AT E R F I LT E R R E P L A C E M E N T A N D R E P L A C E M E N T P A R T S C O N D E N S E R C L E A N I N G S TA I N L E S S S T E E L C L E A...

Страница 42: ...ESENTATIVE TO PERFORM THE MAINTENANCE PROCEDURES FOR YOU True recommends that you perform the following maintenance procedures a minimum of once every six months to ensure reliable trouble free operat...

Страница 43: ...ing water from escaping the evaporator compartment REMOVAL Lift the shutter rod s ends from the recesses in the sidewall INSTALLATION Insert the shutter rod s ends into the recesses in the sidewall To...

Страница 44: ...sh against the back side of the water trough opening ICE GUIDE The ice guide sits over the spray nozzles and directs falling ice into the bin REMOVAL Lift the front of the guide and pull the guide for...

Страница 45: ...in the water trough supplies water to the individual ice cube cups REMOVAL Carefully pull the spray bar from the water supply hose INSTALLATION To be correctly installed the spray bar must Be position...

Страница 46: ...L THE DISPLAY SHOWS FIL THEN PRESS AND HOLD THE POWER BUT TON UNTIL THE DISPLAY SHOWS OFF 3 Insert the replacement water filter and rotate the filter clockwise NOTE LUBRICATE THE FILTER O RINGS PRIOR...

Страница 47: ...worst type of chlorides to use STAINLESS STEEL CLEANING AND RESTORATION Do not use stainless steel cleaners or similar solvents to clean plastic or powder coated parts Instead use warm soapy water Fo...

Страница 48: ...ative Avoid cleaners containing quaternary salts as they can attack stainless steel causing pitting and rusting Rinse When using chlorinated cleaners you must rinse and wipe dry immediately It is bett...

Страница 49: ...d the inside of the machine with ice machine descaler Sanitizing the ice machine is done to remove any biological contamination that may have occurred That process is identical to the descaling proces...

Страница 50: ...TIONS Use the following instructions to prepare your ice machine for storage or winterization 1 Descale and sanitize the ice machine per the instructions in this manual or reference the cleaning and m...

Страница 51: ...pation is part of the ice making process for this machine Q WHY IS THE ICE MACHINE MAKING LESS ICE THAN BEFORE A If the ambient temperature or the water temperature goes up significantly the amount of...

Страница 52: ...normal maintenance after install adjustments or cleaning or water damage claims whether or not on account of refrigeration failure 1 TRUE RESIDENTIAL LIMITED ICE MACHINE WARRANTY TRUE RESIDENTIAL LIMI...

Страница 53: ...subjected after the date of manufacture to alteration neglect abuse misuse accident damage during transit or installation fire flood or act of God IMPROPER ELECTRICAL CONNECTIONS TRUE is not responsib...

Страница 54: ...TRUE RESIDENTIAL TEC_TM_073 REV D EN 12 03 2021 Page 54 of 56 NOTES...

Страница 55: ...15 INCH TRUE ICETM MACHINE INSTALL GUIDE TEC_TM_073 REV D EN 12 03 2021 Page 55 of 56 THANK YOU FOR YOUR PURCHASE...

Страница 56: ...TIAL TEC_TM_073 REV D EN 12 03 2021 Page 56 of 56 EA 05 2021 MISC_2218 974989 CONTACT US t r u e r e s i d e n t i a l c o m 6 3 6 2 4 0 2 4 0 0 t o l l f r e e 8 8 8 616 8 7 8 3 P R E S E R V E T H E...

Отзывы: