background image

6

TRUE

trcb

 – 

chef

 

base

 

equipment

www

.

truemfg

.

com

INSTALLATION OF CASTORS OR 

OPTIONAL LEGS

Important safeguard for installation of leg/castor. Images 1 & 2 
demonstrate procedure.

LEVELING CASTORS

Four sets of shims have been provided in warranty packet for leveling 
castored units positioned on uneven floors. Shims must be positioned 
between cabinet and castor mounting plate. See image 1.

If the cabinet is not level prop up one end of the cabinet between 
castors with a 6" block. See image 2.

NOTE:

 Do not push block more than 5" under cabinet.

Loosen castor bolts with an adjustable wrench enough to slide shims 
between the castor mounting plate and cabinet bottom.

Install the desired number of shims (in pairs as shown in image 1), 
making sure the slots in the shim are in contact with the castor 
mounting bolts.

Tighten and secure the shims and castor(s).  Remove 6" block and 
check to determine if cabinet is level.  Repeat process until cabinet 
is level.

Ensure that the drain hose or hoses are positioned in the pan.

Leveling Shims

Castor

Snug Fit

Here

Leveling Shims

Side View

Top View

Left Shim

In Position

Castor

Mounting

Plate

1

F

°

35

°

6”

2

Содержание TRCB-52

Страница 1: ...ranty Information 14 Stainless Steel Equipment Care and Cleaning 15 WARRANTY Warranty 16 trcb chef base equipment TRUE MANUFACTURING CO INC 2001 East Terra Lane O Fallon Missouri 63366 4434 636 240 24...

Страница 2: ...ety precautions must be followed CAUTION Risk of fire or explosion Dispose of properly in accordance with federal or local regulations Flammable refrigerant used CAUTION Risk of fire or explosion due...

Страница 3: ...PROPERLY GROUNDED The power cord from this appliance is equipped with a grounding plug which minimizes the possibility of electric shock hazard Have the wall outlet and circuit checked by a qualified...

Страница 4: ...bubbles or Styrofoam corners and clear plastic Inspect for concealed damage Again immediately file a claim with the freight carrier if there is damage B Move your unit as close to the final location...

Страница 5: ...0 12 10 8 6 6 6 6 6 5 4 4 3 70 10 10 8 6 6 6 5 5 4 4 2 2 80 10 8 8 6 6 5 5 4 4 3 2 2 90 10 8 6 6 5 5 4 4 3 3 1 1 100 10 8 6 6 5 4 4 3 3 2 1 1 115 Volts Distance In Feet To Center of Load Amps 20 30 40...

Страница 6: ...VENTILATION IS INSUFFICIENT B Proper leveling of your TRUE cooler is critical to operating success for non mobile models Effective condensate removal and door operation will be effected by leveling C...

Страница 7: ...a 6 block See image 2 NOTE Do not push block more than 5 under cabinet Loosen castor bolts with an adjustable wrench enough to slide shims between the castor mounting plate and cabinet bottom Install...

Страница 8: ...hite drawer retainer and pushing back to lock Image 8 Verify drawer operation 5 6 7 8 STANDARD ACCESSORIES DRAWER REMOVAL INSTALLATION Depending on the version and model of the cabinet one of the fol...

Страница 9: ...djustments sequence of operation and more information C Excessive tampering with the control could lead to service difficulties Should it ever become necessary to replace temperature control be sure i...

Страница 10: ...e control may cycle the compressor and evaporator fan s on and off together a The temperature control is sensing the evaporator coil temperature b The temperature control should be set on the 4 or 5 c...

Страница 11: ...turn After making adjustment measure temperature during three cycles before adjusting again NOTE Only adjust the screw small flathead on the face of the control next to the cam See Figure 3 Follow th...

Страница 12: ...ote as to which wire is on which spade terminal STEP 4 Pull out gently from cabinet NOTE Mechanical temperature controllers are affected when functioning at high altitude The cut in and cut out temper...

Страница 13: ...pment www truemfg com O 9 8 7 6 5 4 3 2 1 2 O 9 8 7 5 4 3 2 1 CUT OUT CUT IN COLDER BUL NO CHART CCW Adjustment based on 360 complete turn Height 2000 42 3000 78 4000 114 5000 150 6000 186 7000 222 80...

Страница 14: ...rom the condenser coil and the fan with a stiff bristle brush See image 2 STEP 5 Lift cardboard cover above fan at plastic plugs and carefully clean condenser coil and fan blades STEP 6 After brushing...

Страница 15: ...rill to expose the Condenser The Condenser looks like a group of vertical fins You need to be able to see through the condenser for the unit to function at maximum capacity Do not place filter materia...

Страница 16: ...er will suffice 8 STEPS THAT CAN HELP PREVENT RUST ON STAINLESS STEEL 1 USING THE CORRECT CLEANING TOOLS Use non abrasive tools when cleaning your stainless steel products The stainless steel s passiv...

Страница 17: ...vacuums must be achieved to insure low moisture levels in the system 500 microns or lower must be obtained All claims for labor or parts must be made directly through TRUE All claims should include m...

Отзывы: