background image

............ www.truemfg.com ............

7

7

True Food Service Equipment, Inc.

Adjusting Castors for Proper Leveling

Level unit.  If unit is not level shims are required.  Follow 

these instructions to install shims.  

1.

   Remove front and rear grill depending upon which castor 

needs adjusting.   Locate the castor box.  (See image 1).

2.

   Lay unit on it’s back.  Use soft packing material and be 

careful not to scratch the unit.  Remove pans and lid and 

place them to the side before laying unit on it’s back.

3.

   Each unit has one castor box different from the others.  

This box is totally inclosed.  Remove this castor box from 

bottom of unit.  Back out four screws anchoring the box.  

You will need a 

1

/4” hex head nut driver to disassemble 

this castor box.  (See image 2).

4.

   Loosen castor with tool provided. (See image 3).

5.

   Install the desired number of shims, making sure the slot 

of the shim is in contact with the threaded stem of the 

castor. (See image 4).  If more than one shim is used, turn 

the slot at a 90° angle so they are not in line. 

6.

   After adjusting castor reassemble and reinstall castor box.  

Then carefully upright unit and reinstall pans and lid.

INSTALLATION / OPERATION INSTRUCTIONS

LEVELING AND CASTOR ADJUSTING

TFP MODELS ONLY

1

2

3

4

Locate castor box

One castor box on each unit 
is fully enclosed.

Loosen castor.

Install shims.

Castor Box

Anchor 
Screws

Содержание TFP-48-18M-D-4

Страница 1: ...stallation 22 Maintenance Care Cleaning Cleaning Condenser Coil 23 24 Stainless Steel Equipment Care Cleaning 25 26 Composite Cutting Board Maintenance 26 Periodic Maintenance for Lids 27 Warranty U S...

Страница 2: ...True Food Service Equipment Inc www truemfg com...

Страница 3: ...sonnel Do not puncture refrigerant tubing Caution Risk of fire or explosion Flammable refrigerant used Consult repair manual owner s guide before attempting to service this product All safety precauti...

Страница 4: ...s in place so that children may not easily climb inside Refrigerant Disposal Your old refrigerator may have a cooling system that uses Ozone Depleting chemicals If you are throwing away your old refri...

Страница 5: ...rom the outlet Repair or replace immediately all power cords that have become frayed or otherwise damaged Do not use a cord that shows cracks or abrasion damage along its length or at either end When...

Страница 6: ...tely file a claim with the freight carrier if there is damage B Move your unit as close to the final location as possible before removing the wooden skid C Remove door bracket on swing glass door mode...

Страница 7: ...shipping skid be sure not to damage drain pan at the base of the unit E Appliance tested according to the climate classes 5 and 7 for temperature and relative humidity LOCATING Removing skid from bott...

Страница 8: ...assembly The bearing race on the castor of the top edge of the leg must make firm contact with the rail Unit leveling Four leveling shims have been provided for leveling castored units positioned on u...

Страница 9: ...move this castor box from bottom of unit Back out four screws anchoring the box You will need a 1 4 hex head nut driver to disassemble this castor box See image 2 4 Loosen castor with tool provided Se...

Страница 10: ...f applicable and right bracket CUTTING BOARD RETAINER CLIP TABLE TOP Figure 1 ANCHORING THE TSSU HOOD COVER TSSU Hood Installation Instruction Assembly 1 Locate the lid packaged within the cardboard c...

Страница 11: ...l wiring diagram is positioned on the inside cabinet wall ELECTRICAL INSTRUCTIONS A Set unit in its final location Be sure there is adequate ventilation in your room Under extreme heat conditions 100...

Страница 12: ...10 8 6 6 6 5 5 4 4 3 2 40 10 8 8 6 6 5 5 4 4 3 2 2 45 10 8 6 6 6 5 4 4 3 3 2 1 50 10 8 6 6 5 4 4 3 3 2 1 1 Wire Gauge for 2 Voltage Drop in Supply Circuits 230 Volts Distance In Feet To Center of Load...

Страница 13: ...wall NOTE If the cooler is disconnected or shut off wait five minutes before starting again RECOMMENDATION Before loading product we recommend you run your TRUE unit empty for two to three days This...

Страница 14: ...4 of a revolution clockwise to the right This procedure will adjust both the cut in and cut out about 2 F warmer STEP 5 Make sure to reconnect the pink wire to the proper spade terminal when reinstall...

Страница 15: ...www truemfg com 13 13 True Food Service Equipment Inc TUC 24 HC and TUC 24G HC Only DISPLAY...

Страница 16: ...temperature that will start the compressor Example If the Set Point is 9 F 23 C and the Differential is 10 F 5 C Set Point 9 F 10 Differential 1 F Or Set Point 23 C 5 Differential 18 C The compressor...

Страница 17: ...lock settings If no appears the controller is unlocked If yes appears the controller is locked See images 3 and 4 C Once the lock setting has been set correctly release the info button Wait 5 seconds...

Страница 18: ...interior sign lights by the interior door switch depress the rocker switch to the ON position Light Switch is located on inside top right of the ceiling ON Position Solid Door models lights are contr...

Страница 19: ...ntrol Icons May need to unlock control WHY THE SET POINT IS THE TEMPERATURE AT WHICH THE COMPRESSOR WILL SHUT OFF Please note that the set point IS NOT the cabinet holding temperature HOW A To see the...

Страница 20: ...the Manual Defrost button until dEF appears B REAL TIME CLOCK RTC If controller is preprogrammed for RTC press the and hold the Manual Defrost button for 5 seconds until dh1 appears Release the Manua...

Страница 21: ...he set point press and hold the info button and the stand by button at the same time ScL will appear See image 1 B Push the up button until dFt appears See image 2 C Press and hold the info button to...

Страница 22: ...mps from both ends of the assembly 5 Back off four slotted thumb screws and remove evaporator housing IMPORTANT Note the proper position of the flexible tubing on top of evaporator See Fig 6 Hose will...

Страница 23: ...instability For Proper Shelf Clip Installation Please Read The Following Instructions Step 1 Shelf clips are to be installed into the shelf standards next to the labels on the interior cabinet wall T...

Страница 24: ...r finger to rotate the clips upward see image 3 C Lift drawer and remove from channel see image 4 TFP DRAWER REMOVAL AND INSTALLATION Image 1 Image 3 Image 4 Rotate clip upward Image 2 Installation A...

Страница 25: ...a rejilla hacia arriba y lib rela del soporte de la bocallave Rejillas trasera quite los dos tornillos ver ilustraci n 1 Quite los tornillos que sujetan el montaje del compresor a los rieles del marco...

Страница 26: ...fins You need to be able to see through the condenser for the unit to function at maximum capacity Do not place filter material in front of condensing coil This material blocks air flow to the coil si...

Страница 27: ...plastic scouring pad or soft cloth when you cannot see the grain 3 Use alkaline alkaline chlorinated or non chloride containing cleaners While many traditional cleaners are loaded with chlorides the i...

Страница 28: ...to remove grease and oil F Benefit Super Sheen Sheila Shine are good for restoration passivation NOTE The use of stainless steel cleaners or other such solvents is not recommended on plastic parts War...

Страница 29: ...mportant these are checked periodically to assure they are tight Step 1 Check to see if lid assembly thumbscrews are tight See Image 1 Step 2 Use slotted screwdriver to tighten thumbscrews into place...

Страница 30: ...er must also be the same capacity as the drier being replaced 3 Micron level vacuums must be achieved to insure low moisture levels in the system 500 microns or lower must be obtained All claims for l...

Отзывы: