background image

1

TRUE

traditional

 

reach

-

ins

www

.

truemfg

.

com

Loss or spoilage of products in your refrigerator/

freezer is not covered by warranty.  In addition to 

following recommended installation procedures 

you must run the refrigerator/freezer 24 hours 

prior to usage. 

NOTICE TO  CUSTOMER

WARNING:

  

Use this appliance for its intended purpose as described in this Owner Manual.  

How to Maintain Your True Refrigerator to Receive the Most Efficient and Successful Operation.

You have selected one of the finest commercial refrigeration units made. It is manufactured under strict quality controls with only the best 
quality materials available. Your TRUE cooler when properly maintained will give you many years of trouble-free service.

TO LOCATE REFRIGERANT TYPE, SEE SERIAL LABEL INSIDE CABINET.

  This cabinet may contain fluorinated greenhouse 

gas covered by the Kyoto Protocol (please refer to cabinet’s inner label for type and volume, GWP of 134a= 1,300. R404a= 3,800).

FOR HYDROCARBON REFRIGERATION ONLY (R-290) SEE BELOW:
• DANGER 

- Risk of fire or explosion. Flammable refrigerant used. Do not use mechanical devices to defrost refrigerator. Do not 

puncture refrigerant tubing.

• DANGER

 - Risk of fire or explosion. Flammable refrigerant used. To be repaired only by trained service personnel. Do not puncture 

refrigerant tubing. 

• CAUTION 

- Risk of fire or explosion. Flammable refrigerant used. Consult repair manual/owner’s guide before attempting to service 

this product. All safety precautions must be followed.

• CAUTION

 - Risk of fire or explosion. Dispose of properly in accordance with federal or local regulations. Flammable refrigerant used.

• CAUTION

 - Risk of fire or explosion due to puncture of refrigerant tubing; follow handling instructions carefully. Flammable refrigerant 

used.

• 

CAUTION

 - Keep clear of obstruction all ventilation openings in the appliance enclosure or in the structure for building-in.

SAFETY INFORMATION

SAFETY PRECAUTIONS 

When using electrical appliances, basic safety precautions should be 
followed, including the following:

•  This refrigerator must be properly installed and located in 

accordance with the Installation Instructions before it is used.

•  Do not allow children to climb, stand or hang on the shelves 

in the refrigerator. They could damage the refrigerator and 
seriously injure themselves.

•  Do not touch the cold surfaces in the freezer compartment 

when hands are damp or wet. Skin may stick to these 
extremely cold surfaces.

•  Do not store or use gasoline or other flammable vapors and 

liquids in the vicinity of this or any other appliance. Do not store 
explosive substances such as aerosol cans with a flammable 
propellant in this appliance.

•  Keep fingers out of the “pinch point” areas; clearances between 

the doors and between the doors and cabinet are necessarily 
small; be careful closing doors when children are in the area.

•  Unplug the refrigerator before cleaning and making repairs.
•  Setting temperature controls to the 0 position does not 

remove  power to the light circuit, perimeter heaters, or 
evaporator fans.

NOTE:

  

We strongly recommend that any servicing be preformed 

by a qualified technician.

Содержание T-23-HC

Страница 1: ...OF CONTENTS SAFETY INFORMATION Safety Precautions 1 Proper Disposal Connecting Electricity Adapter Plugs 2 INSTALLATION Ownership Uncrating How to Connect to Electricity 3 Wire Gauge Chart 4 Locating and Leveling 5 Installation of Legs or Castors 5 Sealing Cabinet to the Floor 6 SETUP Standard Accessories 7 Cabinet Adjustment 9 OPERATION Startup 11 Mechanical Temperature Controls Sequence of Opera...

Страница 2: ...ety precautions must be followed CAUTION Risk of fire or explosion Dispose of properly in accordance with federal or local regulations Flammable refrigerant used CAUTION Risk of fire or explosion due to puncture of refrigerant tubing follow handling instructions carefully Flammable refrigerant used CAUTION Keep clear of obstruction all ventilation openings in the appliance enclosure or in the stru...

Страница 3: ... PROPERLY GROUNDED The power cord from this appliance is equipped with a grounding plug which minimizes the possibility of electric shock hazard Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded If the outlet is a standard 2 prong outlet it is your personal respon sibility and obligation to have it replaced with the properly grounded w...

Страница 4: ...e images 4 6 Do not throw the bracket or blocks away For future cabinet movement the bracket and blocks will need to be installed so the glass door does not receive any damage See image for bracket and shipping block removal NOTE KEYS FOR COOLERS WITH DOOR LOCKS ARE LOCATED IN WARRANTY PACKETS 3 4 5 6 INSTALLATION ELECTRIC INSTALLATION SAFETY INFORMATION If the supply cord is damaged it must be re...

Страница 5: ... 8 8 6 6 6 5 5 50 12 10 10 8 6 6 6 6 6 5 4 4 60 12 10 8 6 6 6 6 6 5 4 4 3 70 10 10 8 6 6 6 5 5 4 4 2 2 80 10 8 8 6 6 5 5 4 4 3 2 2 90 10 8 6 6 5 5 4 4 3 3 1 1 100 10 8 6 6 5 4 4 3 3 2 1 1 115 Volts Distance In Feet To Center of Load Amps 20 30 40 50 60 70 80 90 100 120 140 160 2 14 14 14 14 14 14 14 14 14 14 14 14 3 14 14 14 14 14 14 14 14 14 14 14 12 4 14 14 14 14 14 14 14 14 14 12 12 12 5 14 14 ...

Страница 6: ...g castor Images 1 5 demon strate procedure SECURING CASTORS AND LEGS To obtain maximum strength and stability of the unit it is important that you make sure each castor is secure Optional legs are hand tightened securely against the lower rail assembly see image 4 5 The bearing race on the castor or the top edge of the leg must make firm contact with the rail LEVELING SHIMS Four leveling shims hav...

Страница 7: ...o floor on half inch inside the outline drawn The bead must be heavy enough to seal the entire cabinet surface when it is down on the sealant STEP 6 Raise and block the rear of the cabinet STEP 7 Apply sealant on floor as outlined in Step 5 on other three sides STEP 8 Examine to see that cabinet is sealed to floor around entire perimeter NOTE Asphalt floors are very susceptible to chemical attack ...

Страница 8: ...nto shelf standards B Position all four shelf clips equal in distance from the floor for flat shelves C Lower front of gravity feed TrueTrac organizers to enable proper feed D Place shelves on shelf clips making sure all corners are seated properly SETUP Shelf Clip Shelf Shelf Pillaster I beam Shelf Standards T Series GDM 5 Airflow Guard ...

Страница 9: ...e shelf standard The shelf clip should not be loose or able to wiggle out of the shelf standard SHELF INSTALLATION TIPS 1 Install all the shelf clips before installing the shelves 2 Start at the bottom in terms of shelf installation and work your way up 3 Always lay the back of each shelf down on the rear clips before the front WARNING Do not use pliers or any crimping tools when installing shelf ...

Страница 10: ...ing door Three Door Units Slide the middle door to the right so it is centered with the left edge of the right door See image 3 STEP 3 After centering the door lift it up and tilt top of door towards the back of the unit so the rollers are out of the top channel Swing the bottom of the door out of the bottom channel Then remove the door and set it down See image 4 STEP 4 Slide right door to the le...

Страница 11: ...After cabinet is installed in a final location and correctly leveled check for any openings when the slide doors are completely closed If there are any gaps openings between the closed doors and cabinet the doors will need to be adjusted STEP 2 Using a 7 16 wrench or adjustable wrench and 1 8 Allen wrench loosen roller and move along slotted hole After adjustment has been made tighten the roller i...

Страница 12: ...ithin four inches of the evaporator housing Refrigerated air off the coil must circulate down the back wall NOTE If the unit is disconnected or shut off wait five minutes before starting again RECOMMENDATION Before loading product we recommend you run your TRUE unit empty for two to three days This allows you to be sure electrical wiring and installation are correct and no shipping damage has occu...

Страница 13: ...ing unit base This timer is not used for a defrost event The timer will change the rotation of the reversing condenser fan motor MECHANICAL CONTROL FREEZER GENERAL SEQUENCE OF OPERATION 1 Cabinet is plugged in a Interior lights will illuminate on glass door models only If lights do not come on verify the light switch is in the ON position Solid door cabinets may or may not have lights that may be ...

Страница 14: ...turn After making adjustment measure temperature during three cycles before adjusting again NOTE Only adjust the screw small flathead on the face of the control next to the cam See Figure 3 Follow the Altitude Correction Table to the right WARMER COLDER 60 30 45 40 35 50 55 15 20 25 10 5 We advise to make a mechanical temperature control adjustment only for a high altitude location Compressor Term...

Страница 15: ...te as to which wire is on which spade terminal STEP 4 Pull out gently from cabinet NOTE Mechanical temperature controllers are affected when functioning at high altitude The cut in and cut out temperatures will be colder than when the controller functions closer to sea level STEP 5 For high elevation installations it may be necessary to warm up the set points To make the adjustment insert the appr...

Страница 16: ...h ins www truemfg com O 9 8 7 6 5 4 3 2 1 2 O 9 8 7 5 4 3 2 1 CUT OUT CUT IN COLDER BUL NO CHART CCW Adjustment based on 360 complete turn Height 2000 42 3000 78 4000 114 5000 150 6000 186 7000 222 8000 258 9000 294 10 000 330 ...

Страница 17: ...CLOCK OPERATION FOR UNITS WITH MECHANICAL CONTROL RECOMMENDED DEFROST SETTINGS TRUE Manufacturing has factory set your defrost time clock to a recommended time and duration defrost scenario All refrigeration equipment operating below 30 F will accumulate frost on the evapo rator coil and will require routine defrost Your TRUE equipment has been designed for three defrost periods 6 00 a m 2 00 p m ...

Страница 18: ...t temperature This cabinet temperature may reflect the refrigeration cycle of the Set Point and its Differential or it may show an average temperature The most accurate temperature on a cabinets operation is to verify the product temperature Example If the Set Point is 9 F 23 C and the Differential is 10 F 5 C Set Point 9 F 10 Differential 1 F Or Set Point 23 C 5 Differential 18 C The compressor a...

Страница 19: ...ng has been set correctly release the info button Wait 5 seconds for the display to show temperature See image 5 USING THE LAE ELECTRONIC CONTROL LOCKING AND UNLOCKING THE LAE CONTROLLER WHY Locking of control is necessary to prevent changes to program that may affect cabinet operation Image 3 If no appears on screen the controller is unlocked 3 2 1 5 4 Image 4 If yes appears on screen the control...

Страница 20: ...t prior steps and a temperature will appear ON Position TURNING THE GLASS DOOR MODEL LIGHTS ON AND OFF May need to unlock control WHY Light may be controlled by LAE Controller or interior light switch Solid Door model lights are controlled by a door switch HOW TO TURN THE GLASS DOOR MODEL LIGHT ON AND OFF STEP 1 To control interior sign lights by the LAE Controller press and release the Manual Act...

Страница 21: ...ture HOW TO CHANGE THE SET POINT STEP 1 To see the set point press and hold the Info button See image 1 STEP 2 While still holding the Info button press the Up or Down button to change the set point STEP 3 Once the set point has been set correctly release the Info button The display will show temperature See image 2 1 2 LAE Control Manual Activation Up Button Info Set Point Button Stand By Button ...

Страница 22: ...IME DEFROST TIM If controller is preprogrammed for TIM press and release the Manual Defrost button until dEF appears REAL TIME CLOCK RTC If controller is preprogrammed for RTC press the and hold the Manual Defrost button for 5 seconds until dh1 appears Release the Manual Defrost button and then press and hold for an additional 5 seconds until dEF appears NOTE Defrost will only terminate once a spe...

Страница 23: ...TE Depending on the version of control one of three parameters will appear ScL image 1a SPL image 1b MdL image 1c STEP 2 Push the Up button until dFt appears See image 2 STEP 3 Press and hold the Info button to see the defrost interval time See image 3 STEP 4 While pressing and holding the Info button press the Up or Down button to change the defrost interval times higher the number the less frequ...

Страница 24: ...n HOW TO CHANGE DISPLAY READOUT FROM FAHRENHEIT TO CELSIUS STEP 1 To change the display press and hold the Info button and the Stand by button at the same time MdL or SPL will appear See images 1a and 1b STEP 2 Push the Down button until ScL appears See image 2 STEP 3 Press and hold the Info button to see the readout scale See image 3 STEP 4 While pressing and holding the Info button press the up ...

Страница 25: ...3 probe If probe T3 is not activated t3 will not appear of the display DISPLAYING TEMPERATURE PROBES T1 T2 T3 WHY To display temperature probe readings in different locations of the cabinet DISPLAY CODES DISPLAY Defrost in progress Room high temperature alarm Controller in stand by Room low temperature alarm Door open alarm Probe T1 failure Instant Probe 1 temperature Probe T2 failure Instant Prob...

Страница 26: ...elsius AR2 28 SCL 1C ADO SPL X 32 1 8 AHM SPH X 32 1 8 AHT X 32 1 8 SP X 32 1 8 ACC C H IISM HYS X 1 8 IISL X 32 1 8 CRT IISH X 32 1 8 CT1 IISP X 32 1 8 CT2 IIHY X 1 8 CSD IIFC DFM HDS DFT IIDF DH1 SB DH2 DS DH3 DSM DH4 DI2 DH5 STT DH6 EDT DLI X 32 1 8 LSM DTO OA1 DTY OA2 DPD CD DRN INP DDM OS1 X 1 8 DDY T2 FID OS2 X 1 8 FDD X 32 1 8 T3 FTO OS3 X 1 8 FCM TLD FDT X 1 8 TDS FDH X 1 8 AVG FT1 SIM FT2...

Страница 27: ...oving the grill on these models Do not pinch wires For reinstall reattach the grill to the magnets on front of the cabinet and reinstall the screws on top of the grill Phillips Screwdriver Stiff Bristle Brush Adjustable Wrench Air Tank or CO2 Tank Vacuum Cleaner STEP 3 Remove bolts anchoring compressor assembly to frame rails and carefully slide out tube connections are flexible STEP 4 Clean off a...

Страница 28: ...rill to expose the Condenser The Condenser looks like a group of vertical fins You need to be able to see through the condenser for the unit to function at maximum capacity Do not place filter material in front of condensing coil This material blocks air flow to the coil similar to having a dirty coil THE CLEANING OF THE CONDENSER IS NOT COVERED BY THE WARRANTY HOW TO CLEAN THE CONDENSER 1 Disconn...

Страница 29: ... RUST ON STAINLESS STEEL 1 USING THE CORRECT CLEANING TOOLS Use non abrasive tools when cleaning your stainless steel products The stainless steel s passive layer will not be harmed by soft cloths and plastic scouring pads Step 2 tells you how to find the polishing marks 2 CLEANING ALONG THE POLISH LINES Polishing lines or grain are visible on some stainless steels Always scrub parallel to visible...

Страница 30: ...ze the plastic lampshield together and pull away from the door See Image 3 Push the bulb down while pulling the spring activated lampholder up This will give you enough clearance to take the bulb out See Image 4 GENERAL MAINTENANCE LIGHT BULB REPLACEMENT INTERIOR LIGHTS GENERAL MAINTENANCE WARNING When replacing a light bulb make sure power to the unit is either turned off or unplugged Be careful ...

Страница 31: ...r labor or parts must be made directly through TRUE All claims should include model number of the unit the serial number of the cabinet proof of purchase date of installation and all pertinent information supporting the existence of the alleged defect In case of warranty compressor the compressor model tag must be returned to TRUE along with above listed information Any action or breach of these w...

Отзывы: