14
TRUE
traditional
reach
-
ins
www
.
truemfg
.
com
INSTALLATION INSTRUCTIONS
TEMPERATURE CONTROL ALTITUDE ADJUSTMENT:
REQUIRED TOOLS:
• Allen Wrench (5/64”)
• Torx Screw (T-7)
The scale to the right may be used as a guide for measuring degrees of rotation required for altitude
correction. The arrows indicate direction of screw rotation. See Figure 1.
IMPORTANT:
Upright models ordered with “High Altitude” temperature controls are
pre-calibrated and do not require adjustment.
90
180
270
360
1
Scale Guide for Measuring
INSTRUCTIONS: DANFOSS TEMPERATURE CONTROL ADJUSTMENT FOR
HIGH ALTITUDE APPLICATIONS
STEP 1
- Unplug cooler.
STEP 2
- Remove the screws that secure the temperature control to the inset box.
STEP 3
- To make these adjustments it may be necessary to remove the temperature control from the housing.
NOTE:
You may have to remove the wires attached to the control. Take note as to which wire is on which spade terminal.
STEP 4
- Pull out gently from cabinet.
NOTE:
Mechanical temperature controllers are affected when functioning at high altitude.
The cut-in and cut-out temperatures will be colder than when the controller functions closer to sea level.
STEP 5
- For high elevation installations, it may be necessary to “warm-up” the set points. To make the adjustment, insert the
appropriate tool in each adjustment screw and turn 1/4 of a revolution clockwise (to the right). This procedure will adjust both
the cut-in and cut-out about 2˚F warmer.
STEP 6
- Make sure to reconnect the wires to the proper spade terminal when reinstalling.
INSTRUCTIONS: CUTLER HAMMER TEMPERATURE CONTROL ALTITUDE ADJUSTMENT
STEP 1
- Unplug cooler.
STEP 2
- Turn the temperature control to the “9” position.
STEP 3
- Remove the screws that secure the mounting plate to the evaporator top. See Figure 2.
STEP 4
- Pull control down gently from housing.
STEP 5
- Turn screws counterclockwise (CCW).
STEP 6
- Reassemble to cooler housing and return the temperature control to the “5” position.