background image

6

6

True Food Service Equipment, Inc.

............ www.truemfg.com ............

INSTALLATION / OPERATION INSTRUCTIONS

LEVELING AND CASTOR ADJUSTING

A. 

Set unit in its final location. Be sure there is adequate 

ventilation in your room. Under extreme heat 

conditions, (100°F+, 38°C+), you may want to install 

an exhaust fan.

WARNING

Warranty is void if ventilation is insufficient.

B. 

Proper leveling of your TRUE unit is critical to 

operating success (for non-mobile models). Effective 

condensate removal and drawer/door operation will 

be effected by leveling.

C. 

The unit should be leveled from top of the cabinet. 

Place a level on the top of the unit front to back and 

side to side. 

D. 

Ensure that the drain hose or hoses are positioned in 

the pan.

E. 

Free plug and cord from inside the lower rear of the 

cooler (do not plug in).

F. 

The unit should be placed close enough to the 

electrical supply so that extension cords are never 

used.

WARNING

Cabinet warranties are void if OEM power cord is tampered 

with. TRUE will not warranty any units that are connected to 

an extension cord. 

Adjusting Castors for Proper Leveling

Level unit.  If unit is not level shims are required.  

Follow these instructions to install shims.  

1.

  Remove front and rear grill depending upon which 

castor needs adjusting.   Locate the castor box.  (See 

image 1).

2.

  Lay unit on it’s back.  Use soft packing material and 

be careful not to scratch the unit.  Remove pans and 

lid and place them to the side before laying unit on 

it’s back.

3.

   Loosen castor with tool provided. (See image 3).

4.

   Install the desired number of shims, making sure the 

slot of the shim is in contact with the threaded stem 

of the castor. (See image 4).  If more than one shim 

is used, turn the slot at a 90° angle so they are not in 

line. 

5.

   Each unit has one castor box different from the 

others.  This box is totally inclosed.  Remove this 

castor box from bottom of unit.  Back out four 

screws anchoring the box.  You will need a 

1

/

4

” hex 

head nut driver to disassemble this castor box.  (See 

image 4).

6.

  After adjusting castor reassemble and reinstall castor 

box.  Then carefully upright unit and reinstall pans 

and lid.

1

4

2

3

Locate castor box

One castor box on each unit is 
fully inclosed.

Loosen castor.

Install shims.

Castor Box

Anchor 
Screws

Содержание Food Prep TFP-32-12M-D-2

Страница 1: ...ontrol Location 10 Maintenance Care Cleaning Cleaning Condenser Coil 11 12 Stainless Steel Equipment Care Cleaning 13 14 Composite Cutting Board Maintenance 14 Warranty U S A Canada Only 15 INSTALLATI...

Страница 2: ...True Food Service Equipment Inc www truemfg com...

Страница 3: ...children are in the area NOTE We strongly recommend that any servicing be preformed by a qualified individual Unplug the refrigerator before cleaning and making repairs Setting temperature controls to...

Страница 4: ...s in place so that children may not easily climb inside Refrigerant Disposal Your old refrigerator may have a cooling system that uses Ozone Depleting chemicals If you are throwing away your old refri...

Страница 5: ...rom the outlet Repair or replace immediately all power cords that have become frayed or otherwise damaged Do not use a cord that shows cracks or abrasion damage along its length or at either end When...

Страница 6: ...concealed damage Again immediately file a claim with the freight carrier if there is damage B Move your unit as close to the final location as possible before removing the wooden skid NOTE Keys for co...

Страница 7: ...brackets See figure 1 B Remove brackets from both sides of the board C Carefully lift cutting board Figure 1 ANCHORING THE TFP HOOD COVER TFP Hood Installation Instruction A This is TRUE s recommende...

Страница 8: ...connected to an extension cord Adjusting Castors for Proper Leveling Level unit If unit is not level shims are required Follow these instructions to install shims 1 Remove front and rear grill dependi...

Страница 9: ...desired placement See images 1 2 STORAGE BINS INSTALLATION OPERATION INSTRUCTIONS Image 1 Image 2 A For drawer face alignment four screws are located on the back of the drawer face See image 3 B Loose...

Страница 10: ...d WARNING Do not use electrical appliances inside the food storage compartments of the appliances unless they are of the type recommended by the manufacturer NOTE To reference wiring diagram Remove fr...

Страница 11: ...0 8 6 6 6 5 5 4 4 3 2 40 10 8 8 6 6 5 5 4 4 3 2 2 45 10 8 6 6 6 5 4 4 3 3 2 1 50 10 8 6 6 5 4 4 3 3 2 1 1 Wire Gauge for 2 Voltage Drop in Supply Circuits 230 Volts Distance In Feet To Center of Load...

Страница 12: ...RTS TRUE maintains a record of the cabinet serial number for your cooler If at any time during the life of your cooler a part is needed you may obtain this part by furnishing the model number and seri...

Страница 13: ...vemente la rejilla hacia arriba y lib rela del soporte de la bocallave Rejillas trasera quite los dos tornillos ver ilustraci n 1 Quite los tornillos que sujetan el montaje del compresor a los rieles...

Страница 14: ...oup of vertical fins You need to be able to see through the condenser for the unit to function at maximum capacity Do not place filter material in front of condensing coil This material blocks air flo...

Страница 15: ...plastic scouring pad or soft cloth when you cannot see the grain 3 Use alkaline alkaline chlorinated or non chloride containing cleaners While many traditional cleaners are loaded with chlorides the i...

Страница 16: ...to remove grease and oil F Benefit Super Sheen Sheila Shine are good for restoration passivation NOTE The use of stainless steel cleaners or other such solvents is not recommended on plastic parts War...

Страница 17: ...er must also be the same capacity as the drier being replaced 3 Micron level vacuums must be achieved to insure low moisture levels in the system 500 microns or lower must be obtained All claims for l...

Отзывы: