True Food Service Equipment, Inc.
INSTALLATION / OPERATION INSTRUCTIONS
A.
The compressor is ready to operate. Plug in the
cooler.
B.
Temperature control set at No. 4 position gives
refrigerators an approximate temperature of 35°F.
Allow unit to function several hours, completely
cooling cabinet before changing the control setting.
C.
Excessive tampering with the control could lead to
service difficulties. Should it ever become necessary
to replace temperature control, be sure it is ordered
from your TRUE dealer or recommended service
agent.
D.
Good air flow in your TRUE unit is critical. Be
careful to load product so that it neither presses
against the back wall, nor comes within four inches
of the evaporator housing. Refrigerated air off the
coil must circulate down the back wall.
NOTE
If the cooler is disconnected or shut off, wait five minutes before
starting again.
RECOMMENDATION
Before loading product we recommend you run your TRUE unit
empty for two to three days. This allows you to be sure electrical
wiring and installation are correct and no shipping damage
has occurred. Remember, our factory warranty does not cover
product loss!
REPLACEMENT PARTS
TRUE maintains a record of the cabinet serial number for your
cooler. If at any time during the life of your cooler, a part is
needed, you may obtain this part by furnishing the model number
and serial number to the company from whom you purchased
the cooler. Call Toll-Free: (800)-424-TRUE (Direct to Parts
Department). (800)-325-6152 (U.S.A. & Canada only) or call:
(636)-240-2400.
The temperature control is located are the back of the
unit. (See image 1).
TEMPERATURE CONTROL LOCATION
Image 1
SEQUENCE OF OPERATION
Temperature Control Sequence of Operation
When the cabinet is plugged the unit will start up in a defrost cycle. The evaporator fan is hard-wired and will
continue to run during this time. The cooler will stay in defrost for a minimum of 4 minutes or until the coil
temperature reaches at least 41˚F. The maximum time the cooler will be in defrost is 40 minutes. At the end of
the defrost cycle, there will be a 2 minute delay to allow any water to drip off of the evaporator coil. After this
time, the compressors will come on and the cooler should start to cool down. The compressors will run until the
temperature control is satisfied. Every 4 hours of compressor run time, the cooler will go into defrost and remain
in defrost until the coil temperature reaches 41˚F.
NOTE:
When the unit is first plugged in it will take at least 6 minutes
before the compressor starts.