Problem  

Cause 

Cure

Glass is Dirty 

1.   Wood is wet 

•  Use dry wood

 

2.  Turning down air control 

•  Do not turn down until

 

  or damper too soon 

   a) there is a good bed of coals 

 

   

  b) the wood is charred

 

3.  Draft too low 

•  Improper chimney height and / or 

 

   

  diameter, -consult dealer 

 

   

•  Chimney plugged or restricted, 

 

   

  - inspect and clean 

 

   

•  Provide outside air for combustion

 

4.  Door gasket leakage 

•  Replace gasket 

 

   

•  Check latch for proper operation

Excessive Creosote Buildup  

See 1,2,3, above. 

 See 1,2,3, above.

Low Heat Output 

1.  Wood is wet 

•  Use dry wood

 

2.  Fire too small 

•  Build a larger fire

 

3.  Draft too low 

•  Chimney plugged or restricted, 

 

   

  - inspect and clean

 

Won't Burn Overnight 

1.  Air control is set too high 

•  Set air control lower

 

2.  Not enough wood 

•  Unsplit wood is preferred for 

 

   

  overnight burns

 

3.  Draft too high 

•  Excessive chimney height and/or 

 

  

 diameter

 

4.  Poor quality or wet wood 

•  Use good quality, dry wood 

Wood Won't Burn 

1.  Combustion air supply blocked 

•  Check outside air supply for

 

    

  obstruction 

 

  

 

2.  Draft too low 

•  Chimney plugged or restricted, 

 

   

  -inspect and clean

 

   

•  Chimney oversized or otherwise

 

   

  unsuitable, -consult Dealer

Troubleshooting

Appendix A

Содержание TN 20

Страница 1: ...ONS AUSTRALIA SAFETY NOTICE If this stove is not properly installed a house fire may result For your safety follow the installation instructions Contact local building or fire officials about restrictions and installation inspection requirements in your area SERIAL 040217 20 TN20 AUSTRALIA 5055 552AS AUSTRALIA ...

Страница 2: ...oom heater Failure to follow instructions mayresultinpropertydamage bodily injury or even death Contents 2 Safety and Maintenance 3 Maintenance Checks 4 Formation and Need for Removal 5 Chimney Fires 5 Avoiding a Chimney Fire 5 Creosote 5 Appliance Dimensions 6 Assembly 6 If You Suspect a Chimney Fire 6 In Case of a Chimney Fire 6 Clearances Residential 7 Floor Protector 7 Installation 8 Chimney a...

Страница 3: ... or otherwise impact glass When closing door make sure that no logs protrude to impact the glass If the glass gets cracked or broken it must be replaced before using the stove Replacement glass can be obtained from your dealer Use ceramic glass only Do not substitute with any other type GLASS SIZE 337mm x 235mm x 5mm thick To remove broken glass undo the four retaining screws and remove the clamps...

Страница 4: ...il tabs and brick rails Back side of airwash chamber Top Baffle Board Secondary Air Baffle Tubes Boost tube cover When Cleaning the Chimney System Top heat shield and mounting bolt Brick Rails Manifold Replace the Baffle tubes if they show signs of cracking or breakage Please contact your Dealer if you experience any of the damage listed above Continuing to operate your stove with broken parts may...

Страница 5: ...ewillbecondensed Wetorgreenwoodcontributes significantly to creosote formation as the excess moisture that is boiled off cools the fire making it difficult for the tars and gases to ignite thus creating dense smoke and poor combustion This moisture laden smoke cools the chimney compounding the problem by offering the smoke the ideal place to condense In summary a certain amount of creosote is inev...

Страница 6: ...of the top of the chimney In Case of a Chimney Fire 1 Immediately close the air inlets on the stove 2 Evacuate the home and call the local fire department 3 After the chimney fire has been extinguished the chimney must be cleaned and checked for stress and cracking before starting another fire Also check combustibles around the chimney and roof Crate Removal 1 Carefully remove wood top and support...

Страница 7: ...igure 3 Floor Protector Minimum Width 714 mm Minimum Overall Depth 1090mm MinimumClearance to Combustibles 312mm 150mm 620mm 455mm 175mm 175mm 350mm Figure 2 TN 20 AUS clearances ai Non combustible ember protector 86 mm 86 mm 300 mm 714 mm 1090 mm Figure 3 TN 20 AUS Floor protector ai 7 5055 552AS_040217 20 TN 20 Clearances Residential Clearances are based on testing done with a Wildcat Default Fl...

Страница 8: ...THE MARKING TESTED TO AS NZS 4013 ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CON SIDERED TO BE IN BREACH OF THE APPROVAL GRANTED FOR COMPLIANCE WITH AS NZS 4013 CAUTION MIXING OF APPLIANCE OR FLUE SYSTEM COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING THE DIMEN SIONAL SPECIFICATION OF COMPONENTS MAY RESULT IN HAZARDOUS CONDITIONS WHERE SUCH A...

Страница 9: ...e combustion air may be required consult local building codes See Combustion Air section on page 11 2 Installed with the crimped or male ends pointing down This will carry any liquid creosote or condensation back into the stove 3 If a roof or ceiling support is used in the installation you will find the chimney manufacturer s complete instructions packed with the roof support 4 To start installing...

Страница 10: ...ebox 3 Then to install each side brick insert the brick under the retaining flange near the front of the baffle air box on each side of the firebox and then slide the brick to the back of the unit NOTE The retaining flange can be bent outwards slightly if needed to make room for the bricks using a set of visegrips or pliers 4 Finally install the last 4 firebricks by inserting the side brick under ...

Страница 11: ...apter OAIR 1A to the underside of the stove Connect the adapter to the hole using 4 100mm fexible or rigid metal venting Cover the hole with a 20GA wire mesh minimum rodent screen and staple nail in place This hole must get its air from a ventilated crawl space or be extended with duct to the outdoors see Figure 6 on page 11 or Figure 7 on page 11 if extended use an approved 4 102mm inlet vent cap...

Страница 12: ...n this manual are considered your left and right when facing the front of the woodstove Wood Selection This heater is designed to burn natural wood only Higher efficiency and lower emissions generally result when burning air dried seasoned hardwoods as compared to softwoods or too green or freshly cut hardwoods Wood should be properly air dried seasoned for six months or more Wet or undried wood w...

Страница 13: ...od coal base exists and wood has charred Normal Operation 1 Set air control to a desired setting If smoke pours down across the glass waterfall effect this indicates you have shut the control down too soon or you are using too low a setting As every home s heating needs vary based on insulation windows climate etc the proper setting can only be found by trial and error and should be noted for futu...

Страница 14: ...ay cause backpuffing into the room and plugging of the chimney Smoke leaking into the room through appliance and chimney connector joints indicates inadequate draft Ash Removal Whenever ashes get 75 mm to 100 mm inches deep in your firebox and when the fire has burned down and cooled remove excess ashes Leave an ash bed approximately 25 mm deep on the firebox bottom to help maintain a hot charcoal...

Страница 15: ... through the door opening Installation 1 Insert one half of baffle board above the two back baffle tubes inside the firebox slide over to the right and allow to rest on the baffle air assembly 2 Ensure that the second half is inserted to allow the two cuts in the baffle boards to overlap Insert the other half of the baffle board and allow to rest on the left side baffle air assembly 3 With the hol...

Страница 16: ...16 5055 552AS_040217 20 TN 20 ...

Страница 17: ...up See 1 2 3 above See 1 2 3 above Low Heat Output 1 Wood is wet Use dry wood 2 Fire too small Build a larger fire 3 Draft too low Chimney plugged or restricted inspect and clean Won t Burn Overnight 1 Air control is set too high Set air control lower 2 Not enough wood Unsplit wood is preferred for overnight burns 3 Draft too high Excessive chimney height and or diameter 4 Poor quality or wet wood...

Страница 18: ...1 3 Door Casting Assy c w Handle TRNO DRBK 4 Replacement Glass c w gasket TRNO 7025 5 Door Gasket TN19 DGKIT 6 Glass Clamps 4 pcs TRNO 7608 7 Firebrick Set 9 x 4 1 2 x 1 1 4 20 pcs TRNO BRIC 8 Rear Brick Rail c w 2 screws TRNO 7625 9 Quadrant Assembly TRNO 7617 10 Fan Optional TRNO 19EU BLOWA 11 Flame Shield TRNO 7610 12 Secondary Air Chamber Left TRNO 747511 13 Secondary Air Chamber Right TRNO 74...

Страница 19: ...TORIA MAXIMUM AVERAGE HEAT OUTPUT BURNING HARDWOOD 5 4 kW OVERALL AVERAGE EFFICIENCY BURNING HARDWOOD 64 PARTICULATE EMISSIONS FACTOR 1 6g kg CATALYTIC COMBUSTOR NO Distributed by PIVOT STOVES AND HEATING CO 234 238 MOORABOOL STREET GEELONG VIC 3220 pivotstove com au 04 11 16 5050 852AS 19 5055 552AS_040217 20 TN 20 Compliance Plate Compliance plate is located at the rear of the TN 20 ...

Страница 20: ...TD Reproduction adaptation or translation without prior written permission is prohibited except as allowed under the copyright laws PACIFIC ENERGY FIREPLACE PRODUCTS LTD Web site www pacificenergy net 2975 Allenby Rd Duncan BC V9L 6V8 PRINTED IN CANADA ...

Отзывы: