17
5055.552AS_040217-20
TN 20
Problem
Cause
Cure
Glass is Dirty
1. Wood is wet
• Use dry wood
2. Turning down air control
• Do not turn down until
or damper too soon
a) there is a good bed of coals
b) the wood is charred
3. Draft too low
• Improper chimney height and / or
diameter, -consult dealer
• Chimney plugged or restricted,
- inspect and clean
• Provide outside air for combustion
4. Door gasket leakage
• Replace gasket
• Check latch for proper operation
Excessive Creosote Buildup
See 1,2,3, above.
See 1,2,3, above.
Low Heat Output
1. Wood is wet
• Use dry wood
2. Fire too small
• Build a larger fire
3. Draft too low
• Chimney plugged or restricted,
- inspect and clean
Won't Burn Overnight
1. Air control is set too high
• Set air control lower
2. Not enough wood
• Unsplit wood is preferred for
overnight burns
3. Draft too high
• Excessive chimney height and/or
diameter
4. Poor quality or wet wood
• Use good quality, dry wood
Wood Won't Burn
1. Combustion air supply blocked
• Check outside air supply for
obstruction
2. Draft too low
• Chimney plugged or restricted,
-inspect and clean
• Chimney oversized or otherwise
unsuitable, -consult Dealer
Troubleshooting