The stove may be installed on a combustible
floor provided ember protection made from
a 9mm thick non-combustible material
(Bellis Board) with a thermal conductivity
value of .1w/m
2
degree K.
This protection must extend as follows:
300 mm on the firing side and be placed
centrally to both sides of the door opening.
See Figure #3.
Floor Protector
Minimum Width - 714 mm
Minimum Overall Depth - 1090mm
MinimumClearance to Combustibles
312mm
150mm
620mm
455mm
175mm
175mm
350mm
Figure 2.
TN 20 AUS clearances.ai
Non-combustible
ember protector
86 mm
86 mm
300 mm
714 mm
1090 mm
Figure 3.
TN 20 AUS Floor protector.ai
7
5055.552AS_040217-20
TN 20
Clearances - Residential
Clearances are based on testing done with a
Wildcat Default Flue kit or equivelent.
MUST ONLY BE INSTALLED BY AN AUTHORISED PERSON IN COMPLIANCE WITH AS/NZS 2918