True Manufacturing Company TR1RRI-1S Скачать руководство пользователя страница 6

............ www.truemfg.com ............

True Food Service Equipment, Inc.

INSTALLATION / OPERATION INSTRUCTIONS

To ensure that your unit works properly from the first 

day, it must be installed properly. We highly recommend 

a trained refrigeration mechanic and electrician install 

your TRUE equipment. The cost of a professional 

installation is money well spent.

Before you start to install your TRUE unit, carefully 

inspect it for freight damage. If damage is discovered, 

immediately file a claim with the delivery freight carrier. 

TRUE is not responsible for damage incurred during 

shipment. 

OWNERSHIP

•  Adjustable Wrench
•  Phillips Head Screwdriver
•  Level

REQUIRED TOOLS

The following procedure is recommended for uncrating 

the unit:

A.

  Remove the outer packaging, (cardboard and bubbles or 

styrofoam corners and clear plastic). Inspect for con-

cealed damage. Again, immediately file a claim with 

the freight carrier if there is damage. 

B.

  Move your unit as close to the final location as possi-

ble before removing the wooden skid.

C.

  Remove door bracket on glass door models. Do not 

throw this bracket away. For future cabinet move-

ment this bracket will need to be installed so glass 

door does not receive any damage. (See image for 

bracket removal.)

NOTE 

Keys for coolers with door locks are located  

in warranty packets.

UNCRATING

INSTALLATION / OPERATION INSTRUCTIONS

REMOTE UNITS (This section applies to remotes only!)

•  Remote cabinets must be ordered as remote.  

 

  We do not recommend converting for a standard   

  self contained to remote system.
•  All remote cabinets must be hard wired.
•  No castors available.
•  All remote cabinets come standard using  

  404A refrigerant.
•  All remote units come standard with expansion    

  valve, liquid line solenoid, heated condensate pan,  

  and defrost timer when applicable.

•   Contact TRUE Technical Service for  

  BTU requirements.
•  No wiring necessary between cabinet and   

 

  condensing unit.
•  All remote condensing units purchased from  

 

  TRUE are 208/230 volts single phase.

If you have any questions regarding this section, please 

call TRUE at 1-(800)-325-6152.

4

4

Содержание TR1RRI-1S

Страница 1: ...re Display___________________ 11 Temperature Control Adjustment_______________ 12 Shelving Pilaster Installation Operation________13 17 Defrost Time Clock Operation Grasslin __________ 18 Maintenance...

Страница 2: ...www truemfg com True Food Service Equipment Inc...

Страница 3: ...ed individual Unplug the refrigerator before cleaning and making repairs Setting temperature controls to the 0 position does not remove power to the light circuit perimeter heat ers or evaporator fans...

Страница 4: ...re getting rid of your old refrigerator please follow the instructions below to help prevent accidents Before You Throw Away Your Old Refrigerator or Freezer Take off the doors Leave the shelves in pl...

Страница 5: ...es Never unplug your refrigerator by pulling on the power cord Always grip plug firmly and pull straight out from the outlet Repair or replace immediately all power cords that have become frayed or ot...

Страница 6: ...unit as close to the final location as possi ble before removing the wooden skid C Remove door bracket on glass door models Do not throw this bracket away For future cabinet move ment this bracket wil...

Страница 7: ...EP 3 Locate and remove the screws on top of the rain shield You can now remove the rain shield Be sure to lay it down on a flat surface to prevent the rain shield from falling over and being damaged S...

Страница 8: ...e doors and be sure they are closing smoothly and not binding up on the ramp To adjust door sweeper gasket loosen slotted thumbscrews The gasket can then be moved up or down and side to side The gaske...

Страница 9: ...6 6 6 6 5 4 4 3 35 10 10 8 6 6 6 5 5 4 4 3 2 40 10 8 8 6 6 5 5 4 4 3 2 2 45 10 8 6 6 6 5 4 4 3 3 2 1 50 10 8 6 6 5 4 4 3 3 2 1 1 Wire Gauge for 2 Voltage Drop in Supply Circuits 230 Volt Distance In...

Страница 10: ...ded for leveling castored units positioned on uneven floors Shims must be positioned between rail end and bearing race A Turn the bearing race counter clockwise until the cabinet is level Level front...

Страница 11: ...stics available at hard ware stores C When applying the cove base trim thoroughly clean both the cabinet and floor of dirt and grease Apply a recommended contact cement to the cove base trim After cov...

Страница 12: ...ee image 1 RAMP INSTALLATION FOR ROLL IN CABINETS 1 3 2 4 DOOR SWEEP GASKET ADJUSTMENT To adjust door sweeper gasket loosen slotted thumb screws The gasket can then be moved up or down and side to sid...

Страница 13: ...UE dealer or a recommended service agent D Good air flow in your TRUE unit is critical Be careful to load product so that it neither presses against the back wall nor comes within four inches of the e...

Страница 14: ...he adjust ment insert the appropriate tool in each adjustment screw and turn 1 4 of a revolution clockwise to the right This procedure will adjust both the cut in and cut out about 2 F warmer STEP 5 M...

Страница 15: ...rts will need to be installed at the same height to keep the shelf level Once the shelves are installed plug the remaining thread ed holes with the plastic plugs provided see image 3 PILASTER INSTALLA...

Страница 16: ...into the Pilasters with a rubber Mallet Angle Rod Type shelving uses a 18 1 8 distance between Pilasters Universal Tray slides have a 21 1 4 distance between Pilasters see image 14 After the pilaster...

Страница 17: ...ort bars are fac ing down D Place shelves on shelf clips making sure all corners are seated properly INSTALLING SHELF STANDARDS IN HEATED CABINETS See Image 2 A When installing shelf standards make su...

Страница 18: ...890080 BACK GUARD 890385 BACK GUARD 890385 BACK GUARD 890385 BACK GUARD 890385 TA TG TR1RPT 1S 1S 1 TRAY SLIDE 2 TRAY SLIDE UNIVERSAL TRAY SLIDE WIRE SHELF PART 890096 PART 890075 PART 890070 PART 89...

Страница 19: ...TA TG TR1DT 2HS 3 5 8 TYP 18 3 8 CRITICAL 3 5 8 TYP 18 3 8 CRITICAL 18 3 8 CRITICAL 24 5 8 2 1 8 TYP 2 1 8 TYP 21 3 8 CRITICAL PILASTER F 890139 890140 PILASTERG BACK GUARD 890141 BACK GUARD 890141 B...

Страница 20: ...d time or temperature terminated Your TRUE freezer contains a defrost system that is temperature terminated however the time clock has been designed with a time termination back up so that the defrost...

Страница 21: ...f accumulated dirt from the condenser coil and the fan with a stiff bristle brush After brushing the components off vacuum all dirt residue from the coil fan and surrounding areas NOTE Single door fre...

Страница 22: ...binet rainshield to expose the Condenser TR TA and TG models The Condenser looks like a group of vertical fins You need to be able to see through the condenser for the unit to function at maximum capa...

Страница 23: ...oft cloth when you cannot see the grain 3 Use alkaline alkaline chlorinated or non chloride containing cleaners While many traditional cleaners are loaded with chlorides the industry is providing an e...

Страница 24: ...emove grease and oil F Benefit Super Sheen Sheila Shine are good for restoration passivation NOTE The use of stainless steel cleaners or other such solvents is not recommended on plastic parts Warm so...

Страница 25: ...levels in the system 500 microns or lower must be obtained WARRANTY CLAIMS All claims for labor or parts must be made directly through TRUE All claims should include model number of the unit the seri...