True Manufacturing Company TR1RRI-1S Скачать руководство пользователя страница 21

............ www.truemfg.com ............

True Food Service Equipment, Inc.

19

19

•  Disconnect power to unit.
•  Three door units will need the rainshield removed to 

easily access the condenser coil for cleaning. Back out the 

top screws (see image 2) and the bottom screws (see image 

3) anchoring the rainshield. Unplug the wires connected 

to the rear of the digital temperature thermometer (see 

image 3) and set the rainshield to the side.

NOTE (For Three Door Units Only) 

Remember to mark which wire plugs into the rear of the digital 

temperature thermometer for easy assembly of the rainshield.

•  Clean off accumulated dirt from the condenser coil 

and the fan with a stiff bristle brush. After brushing the 

components off vacuum all dirt residue from the coil, fan, 

and surrounding areas.

NOTE 

Single door freezer models are supplied with a long handle 

stiff bristle brush. This brush is used to reach through tight 

clearances when cleaning the condenser coil (see image 1).

MAINTENANCE, CARE & CLEANING

CLEANING THE CONDENSER COIL

When using electrical appliances, basic safety precautions should be followed, including the following:

Single Door Freezer unit
(Brush Provided)

Three Door Freezer unit
(Rainshield Removal/top 
screws)

Three Door Freezer unit
(Rainshield Removal / bottom 
screws)

Digital Temperature Control Connections.
(Rainshield Removal)

1

2

3

4

MAINTENANCE, CARE & CLEANING

Содержание TR1RRI-1S

Страница 1: ...re Display___________________ 11 Temperature Control Adjustment_______________ 12 Shelving Pilaster Installation Operation________13 17 Defrost Time Clock Operation Grasslin __________ 18 Maintenance...

Страница 2: ...www truemfg com True Food Service Equipment Inc...

Страница 3: ...ed individual Unplug the refrigerator before cleaning and making repairs Setting temperature controls to the 0 position does not remove power to the light circuit perimeter heat ers or evaporator fans...

Страница 4: ...re getting rid of your old refrigerator please follow the instructions below to help prevent accidents Before You Throw Away Your Old Refrigerator or Freezer Take off the doors Leave the shelves in pl...

Страница 5: ...es Never unplug your refrigerator by pulling on the power cord Always grip plug firmly and pull straight out from the outlet Repair or replace immediately all power cords that have become frayed or ot...

Страница 6: ...unit as close to the final location as possi ble before removing the wooden skid C Remove door bracket on glass door models Do not throw this bracket away For future cabinet move ment this bracket wil...

Страница 7: ...EP 3 Locate and remove the screws on top of the rain shield You can now remove the rain shield Be sure to lay it down on a flat surface to prevent the rain shield from falling over and being damaged S...

Страница 8: ...e doors and be sure they are closing smoothly and not binding up on the ramp To adjust door sweeper gasket loosen slotted thumbscrews The gasket can then be moved up or down and side to side The gaske...

Страница 9: ...6 6 6 6 5 4 4 3 35 10 10 8 6 6 6 5 5 4 4 3 2 40 10 8 8 6 6 5 5 4 4 3 2 2 45 10 8 6 6 6 5 4 4 3 3 2 1 50 10 8 6 6 5 4 4 3 3 2 1 1 Wire Gauge for 2 Voltage Drop in Supply Circuits 230 Volt Distance In...

Страница 10: ...ded for leveling castored units positioned on uneven floors Shims must be positioned between rail end and bearing race A Turn the bearing race counter clockwise until the cabinet is level Level front...

Страница 11: ...stics available at hard ware stores C When applying the cove base trim thoroughly clean both the cabinet and floor of dirt and grease Apply a recommended contact cement to the cove base trim After cov...

Страница 12: ...ee image 1 RAMP INSTALLATION FOR ROLL IN CABINETS 1 3 2 4 DOOR SWEEP GASKET ADJUSTMENT To adjust door sweeper gasket loosen slotted thumb screws The gasket can then be moved up or down and side to sid...

Страница 13: ...UE dealer or a recommended service agent D Good air flow in your TRUE unit is critical Be careful to load product so that it neither presses against the back wall nor comes within four inches of the e...

Страница 14: ...he adjust ment insert the appropriate tool in each adjustment screw and turn 1 4 of a revolution clockwise to the right This procedure will adjust both the cut in and cut out about 2 F warmer STEP 5 M...

Страница 15: ...rts will need to be installed at the same height to keep the shelf level Once the shelves are installed plug the remaining thread ed holes with the plastic plugs provided see image 3 PILASTER INSTALLA...

Страница 16: ...into the Pilasters with a rubber Mallet Angle Rod Type shelving uses a 18 1 8 distance between Pilasters Universal Tray slides have a 21 1 4 distance between Pilasters see image 14 After the pilaster...

Страница 17: ...ort bars are fac ing down D Place shelves on shelf clips making sure all corners are seated properly INSTALLING SHELF STANDARDS IN HEATED CABINETS See Image 2 A When installing shelf standards make su...

Страница 18: ...890080 BACK GUARD 890385 BACK GUARD 890385 BACK GUARD 890385 BACK GUARD 890385 TA TG TR1RPT 1S 1S 1 TRAY SLIDE 2 TRAY SLIDE UNIVERSAL TRAY SLIDE WIRE SHELF PART 890096 PART 890075 PART 890070 PART 89...

Страница 19: ...TA TG TR1DT 2HS 3 5 8 TYP 18 3 8 CRITICAL 3 5 8 TYP 18 3 8 CRITICAL 18 3 8 CRITICAL 24 5 8 2 1 8 TYP 2 1 8 TYP 21 3 8 CRITICAL PILASTER F 890139 890140 PILASTERG BACK GUARD 890141 BACK GUARD 890141 B...

Страница 20: ...d time or temperature terminated Your TRUE freezer contains a defrost system that is temperature terminated however the time clock has been designed with a time termination back up so that the defrost...

Страница 21: ...f accumulated dirt from the condenser coil and the fan with a stiff bristle brush After brushing the components off vacuum all dirt residue from the coil fan and surrounding areas NOTE Single door fre...

Страница 22: ...binet rainshield to expose the Condenser TR TA and TG models The Condenser looks like a group of vertical fins You need to be able to see through the condenser for the unit to function at maximum capa...

Страница 23: ...oft cloth when you cannot see the grain 3 Use alkaline alkaline chlorinated or non chloride containing cleaners While many traditional cleaners are loaded with chlorides the industry is providing an e...

Страница 24: ...emove grease and oil F Benefit Super Sheen Sheila Shine are good for restoration passivation NOTE The use of stainless steel cleaners or other such solvents is not recommended on plastic parts Warm so...

Страница 25: ...levels in the system 500 microns or lower must be obtained WARRANTY CLAIMS All claims for labor or parts must be made directly through TRUE All claims should include model number of the unit the seri...

Отзывы: