............ www.truemfg.com ............
True Food International Equipment, Inc.
12
12
SCL
C
readout scale
SPL
-26
minimum set point
SPH
-12
maximum set point
SP
-21
set point
C-H
REF
mode (heat/cool)
HYS
3.5
differential
CRT
3
comp rest time
CT1
5
comp run fault probe 1
CT2
5
comp stop fault probe 1
CSD
30
comp stop delay with door open
DFM
RTC
defrost start mode
DFT
0
time interval for defrost
DH1
7
scheduled time for defrost
DH2
11
scheduled time for defrost
DH3
16
scheduled time for defrost
DH4
22
scheduled time for defrost
DH5
0
scheduled time for defrost
DH6
0
scheduled time for defrost
DLI
10
defrost end temperature
DTO
30
maximum defrost duration
DTY
ELE
defrost type (electric / gas)
DPD
20
evaporator pump down
DRN
2
pause after defrost (drain time)
DDM
DEF
defrost display mode
DDY
40
display delay
FID
NO
fans active during defrost
FDD
-2
evap fan restart temp after defrost
FTO
5
maximum evap fan stop after defrost
FCM
TIM
fan control mode (non/tmp/tim)
FDT
-0.8
evap-air temp diff for fans to stop
FDH
1.6
fan differential for fan re-start
FT1
30
fan stop delay after comp stop
FT2
4
timed fan stop
FT3
1
timed fan run
ATM
ABS
alarm (non/abs/rel)
ALA
-50
low temp alarm
AHA
-1
high temp alarm
ALR
0
low temp alarm differential
AHR
0
high temp alarm differential
ATI
T1
probe used for alarm
ATD
50
delay before alarm warning
ADO
30
delay before door alarm
AHM
ALR
operation for high cond alarm
AHT
65
condensation temp alarm
ACC
0
condenser period cleaning
IISM
NON
switchover mode for 2nd parameter
IISL
-250
minimum limit for IISP setting
IISH
250
maximum limit for IISP setting
IISP
-200
set point in mode 2
IIHY
40
differential in mode 2 (yes/no)
IIFC
NON
controller sensitivity for auto switchover
HDS
10
fan control in mode 2
IIDF
6
defrost timer set to start in defrost mode 2
SB
NO
standby button enabled (yes/no)
DS
NO
door switch
DI2
NON
digital input operation
STT
23.5
start time for timed actions
EDT
23.5
end time for timed actions
LSM
NON
light control mode (dor/man/non)
OA1
NON
aux 1 output operation
OA2
NON
aux 2 output operation
2CD
0
auxillary compressor start delay
INP
SN4
temp sensor probe selection
OS1
0
probe T1
T2
YES
probe T2 enabled (evap)
OS2
0
probe T2 offset
T3
NON
probe T3 operation
OS3
0
probe T3 offset
TLD
5
delay for min temp and max temp
SIM
3
display slowdown
ADR
1
address for PC communication
TGU FREEZER CONTROLLER SETTINGS
ALL OTHER SETTINGS ARE FACTORY PRE-SET AND SHOULD NOT BE CHANGED.
If you have any questions, please call TRUE technical service.
TRUE EUROPE • Fields End Road • Goldthorpe • NR, Rotherham • South Yorkshire UK
UK Office/Tec44 (0) 1709 888 888 • UK Free Phone 0800 783 2049
UK Free Phone from France, Germany, Netherlands, Belgium & Republic of Ireland 00-880-8783-4685
TRUE FOOD INTERNATIONAL, INC. • 2001 East Terra Lane • O’Fallon • Missouri • 63366-4434 • USA
USA Office/Technical (001) 636-240-2400 • Email [email protected]