LC T-T_empty after each measurement
5.15 Press button "5" (empty after measurement)
Select if the LC T-T should be emptying or not after each measurement.
(Our proposal is to choose for milk quantity measurement without emptying)
Press the "1" button (without emptying), the LC T-T will not be
emptied.
Enter a weighted quantity of milk for online measurement
5.16 Press button "8" (weighted milk quantity)
5.17 Press button "2"
5.18 Switch to the next menu with "ENTER".
Enter the sampling during online measurement
5.19 Press button "9" (Enter sample)
5.20 Press the "2" button
Then, press four times "CLEAR" to get back to the main menu.
6 Problem of a not completely empty LC T-T
Very low levels cannot be measured exactly, as the output of the pressure pipe is not
completely covered with liquid. After emptying, an empty LC T-T is assumed. If the LC T-T
is not empty at the start of the measurement, errors in the milk quantity measurement will
result.
Residual milk
and milk foam
Pressure pipe for
measuring the level
of the milk
Fluid Cover LC T-T