9
Note:
It does not matter which portion of the bubble you use, the top, bottom, or middle
portion can be used with equal precision. What’s important is that once you have decided on
which part of the bubble to use, you are consistent.
a)
If adjustment is needed, use the camber adjustment knob, which is in the
middle of the vertical post of the gauge
b)
If a higher degree of camber is required than the scale allows you may
choose a different value to zero to. I.E. for eight degrees of positive
camber you would simply choose the negative five on the scale as your
zero.
4)
Once the camber bubble is zeroed on the camber scale, calibration is complete for the
camber on that gauge.
5)
Use the same procedure to calibrate each of the Combi gauges (TR-38 and TR-39).
Note:
once the Combi gauges have been calibrated, place them on the two disks, which are on the
right and left side of the calibration bar and closest to the Fixed Returned Mirrors. Verify
that both Camber scales are equal and opposite.
CASTER ZERO ADJUST
CASTER SCALE
CAMBER ZERO SET
SAI LOCK
SAI SCALE
LIVE CASTER ADJUSTMENT
CAMBER SCALE
TR- 30 EASY CHECK GAUGE
FIGURE 3