BVDAX FOR SMOKE
EXTRACT IN
COMBINATION WITH A
FREQUENCY INVERTER

BVDAX for smoke extraction

operation with frequency

inverter, CE-certified according

to EN12101-1 Temperature

category F400

WITH TROXNETCOM AS
AN OPTION

With TROXNETCOM as an

option

 

 

FOR MECHANICAL SMOKE
EXTRACT SYSTEMS AND
PRESSURISATION
SYSTEMS

For mechanical smoke extract

systems and pressurisation

systems

MAXIMUM PERFORMANCE
WITH MAXIMUM SIZE B =
1.20 M, H = 2.03 M

Maximum size, maximum

performance

B = 1.20 m, H = 2.03 m

TYPE EK-JZ

FOR USE IN MECHANICAL SMOKE EXTRACT SYSTEMS,
PRESSURISATION SYSTEMS, AND NATURAL SMOKE
AND HEAT EXHAUST SYSTEMS, ALSO FOR USE AS AN
ADDITIONAL SUPPLY AIR INLET

 

Rectangular smoke control dampers with ventilation function, low installation

depth and large cross section for heat and smoke exhaust with mechanical

smoke extract systems, for the provision of additional supply air and for use in

pressurisation systems

Nominal sizes 200 × 430 – 1200 × 2030 mm, for smoke gas flow rates up to

87700 m³/h or 24360 l/s at 10 m/s

Quick and easy installation in or on building structures, for smoke and heat

exhaust, remote control with an actuator

Casing, damper blades and actuator encasing made of temperature-

resistant calcium silicate

Fulfils pressure level 2 (operating pressure -1000 to 500 Pa)

Automatic release (AA), option of manual override (MA)

For smoke extract ducts from 35 mm wall thickness

C

 = for the smoke extract and ventilation function in combined systems

and thus pneumatic volume flow rate balancing via the selection of

intermediate positions

Closed blade air leakage to EN 1751, class 3

Casing air leakage to EN 1751, class C

Optional equipment and accessories

Cover grille (various constructions)

Connecting subframe for calcium silicate and sheet steel smoke extract

ducts

Integration into the central BMS with TROXNETCOM

Coating for use in exterior walls

Modulation control for selection of desired damper blade positions

Installation accessories

mod

 Configure now

Homepage

>

Products

>

Fire and Smoke Protection

>

Smoke Control Damper

>

Type EK-JZ

Содержание EK-JZ

Страница 1: ...l sizes 200 430 1200 2030 mm for smoke gas flow rates up to 87700 m h or 24360 l s at 10 m s Quick and easy installation in or on building structures for smoke and heat exhaust remote control with an...

Страница 2: ...combined systems and thus pneumatic volume flow rate balancing via the selection of intermediate positions Complies with the requirements of EN 12101 8 Tested to EN 1366 2 and 1366 10 for fire resist...

Страница 3: ...control TROX X smoke exhaust fans from the X FANS subassembly Smoke exhaust fan for roof installation BVDAX BVD Smoke exhaust fan for wall installation BVW BVWAXN Smoke exhaust centrifugal fan BVREH B...

Страница 4: ...eliability of the smoke control damper must be tested at least every six months this has to be arranged by the owner of the smoke extract system functional tests must be carried out in compliance with...

Страница 5: ...n automatically or manually triggered control signal According to the specified time temperature curve an EK JZ can still fully open or close after 25 minutes MA manual release Similarly position chan...

Страница 6: ...30 1050 430 2 0 32 0 45 30 1100 430 2 0 34 0 47 30 1150 430 2 0 35 0 49 30 1200 430 2 0 37 0 52 30 200 630 3 0 09 0 13 36 250 630 3 0 12 0 16 35 300 630 3 0 14 0 19 34 350 630 3 0 16 0 22 33 400 630 3...

Страница 7: ...27 200 1030 5 0 16 0 21 34 250 1030 5 0 2 0 26 33 300 1030 5 0 24 0 31 32 350 1030 5 0 28 0 36 31 400 1030 5 0 32 0 41 31 450 1030 5 0 35 0 46 30 500 1030 5 0 39 0 52 30 550 1030 5 0 43 0 57 29 600 10...

Страница 8: ...6 1 14 1 48 25 200 1430 7 0 22 0 29 32 250 1430 7 0 28 0 36 31 300 1430 7 0 33 0 43 30 350 1430 7 0 39 0 50 30 400 1430 7 0 44 0 57 29 450 1430 7 0 50 0 64 29 500 1430 7 0 55 0 72 28 550 1430 7 0 61 0...

Страница 9: ...30 8 1 52 1 96 24 200 1830 9 0 29 0 37 31 250 1830 9 0 36 0 46 30 300 1830 9 0 43 0 55 29 350 1830 9 0 50 0 64 29 400 1830 9 0 57 0 73 28 450 1830 9 0 64 0 82 28 500 1830 9 0 71 0 92 27 550 1830 9 0 7...

Страница 10: ...1 83 2 33 23 1200 2030 10 1 91 2 44 23 B H n Number of blades n Cross section A m Cross section A m Sound reduction index R dB Free 2 geo 2 w Quick sizing tables provide a good overview of the volume...

Страница 11: ...and casing airleakage to EN 1751 class C Low sound power level and differential pressure Any airflow direction Manual release is also possible using TROXNETCOM Integration into the central BMS with st...

Страница 12: ...tor side Sign 2 defines installation side Example FA Connecting subframe on the operating side crimped wire mesh on the installation sideAny combination is possible 8 Attachments 2 Belimo actuators B2...

Страница 13: ...issioning Installation on in concrete or masonry shaft walls Installation in lightweight partition walls Installation in shaft walls that are covered on one side Installation in or on tested fire resi...