Trox Technik DID301 Скачать руководство пользователя страница 2

General Information

1.1

Introduction

3

1.2

Safety

3

1.3

Symbols used in this manual

3

1.4

Receiving, Inspection and Storage

3

1.4

Damage reporting

3

Product Description and Installation Preparation

2.1

Product overview

4

2.2

Construction description

4

2.3

Application precautions

4

2.4

Preparation for installation

4

2.4

Items provided by installer

4

2.4

Precautions

4

Installation

3.1

General procedure

5

3.2

Installation considerations

5

3.3

Hanging the chilled beam

5

3.4

Air connections

6

3.5

Water connections

6

3.6

Flushing the water piping system

7

3.7

Filling and venting the water system

7

3.8

Typical installations

7

Commissioning

4.1

Waterside commissioning

8

4.2

Airside commissioning

8

4.3

Airside commissioning tables

8-9

Maintenance

5.1

Cleaning instructions

9

5.2

Replacement parts

9

Troubleshooting

6.1

Symptoms & Solutions

10

Warranties

7.1

Representations and Warranties

11

Contents

TROX USA, Inc.

4305 Settingdown Circle

Cumming, Georgia 30028

Phone: 770.569.1433

Fax:

770.569.1435

E-Mail: [email protected]

www.troxusa.com

2

© 2014 TROX GmbH 

All rights reserved.

DID301-302 Installation, Operation & Maintenance Manual (USA)  (06/2015)

No part of this document may be reproduced in any form (by printing, photocopying or other means)

or processed, duplicated or circulated electronically without prior written approval by TROX GmbH.

Содержание DID301

Страница 1: ...Installation Operation and Maintenance Manual Active Chilled Beams Type DID301 and DID302 OM US DID301 302 6...

Страница 2: ...ng and venting the water system 7 3 8 Typical installations 7 Commissioning 4 1 Waterside commissioning 8 4 2 Airside commissioning 8 4 3 Airside commissioning tables 8 9 Maintenance 5 1 Cleaning inst...

Страница 3: ...ngs and important notices or information read the complete manual before installation and be familiar with the meaning of the safety symbols in the next section 1 3 1 3 Symbols used in this manual Whe...

Страница 4: ...hoses recommended for water connections from assembly to the supply and return water circuits unless factory furnished flexible hoses are included with product order or hard connections 3 Precautions...

Страница 5: ...direction The unit is provided with sliding hanging brackets that allow for adjustment along the length and width of the beam both shown here Guidelines when using rods Install Unistrut with appropria...

Страница 6: ...he final water connections STEP THREE Make water connections If NPT connections apply do NOT over tighten applying excessive force on the water pipes may damage the heat exchange coil NOTE See section...

Страница 7: ...ontinuous venting is necessary The installation of both manual and automatic venting systems is recommended The pump should only be started when filling is complete To remove all air from the system t...

Страница 8: ...rimary air chamber in W G DID301 302 Installation Operation Maintenance Manual USA 06 2015 Open pressure cap Min bending radius 3 2 Flexible hose For water connection NPT Female swivel thread for conn...

Страница 9: ...e locked position To clean the beam face If necessary the face of the beam and visible painted surfaces can be cleaned using a mild detergent diluted with warm water Apply with a soft cloth rinse and...

Страница 10: ...sign figure Obstruction on induction grille or heat exchanger coil Remove induction grille and inspect clean grille and heat exchanger as necessary Air connection detached from beam Inspect attachment...

Страница 11: ...t any such covered defect or to replace or exchange the Product Customer shall bear all shipping and handling expenses related to the return of the Products Any repaired corrected replaced or exchange...

Страница 12: ...Maintenance Manual USA 06 2015 TROX USA Inc 4305 Settingdown Circle Cumming Georgia 30028 Phone 770 569 1433 Fax 770 569 1435 E Mail trox troxusa com www troxusa com U S Edition 2015 DID301 302 Insta...

Отзывы: