Fig. 2: Schematic illustration of AIRNAMIC, nominal sizes 160 and 250, with spigot for connection to a ver-
tical duct

1

Diffuser face

2

Bayonet fixing

3

Spigot

4

Screw fixing of the spigot

Important notes

Information on the installation manual

This manual enables operating or service personnel
to correctly install the product described below and
to use it safely and efficiently.

It is essential that these individuals read and fully
understand this manual before starting any work.
The basic prerequisite for safe working is to comply
with the safety notes and all instructions in this
manual.

The local regulations for health and safety at work
and general safety regulations also apply.

Qualified staff

Specialist personnel

Specialist personnel are individuals who have suffi-
cient professional or technical training, knowledge
and actual experience to enable them to carry out
their assigned duties, understand any potential haz-
ards related to the work under consideration, and
recognise and avoid any risks involved.

Limitation of liability

The information in this manual has been compiled
with reference to the applicable standards and
guidelines, the state of the art, and our expertise
and experience of many years.

The manufacturer does not accept any liability for
damages resulting from:

Non-compliance with this manual

Incorrect use

Operation or handling by untrained individuals

Unauthorised modifications

Important notes

 

Air terminal devices AIRNAMIC

2

Содержание AIRNAMIC Series

Страница 1: ...ising element Z for supply air Suspension lug Spigot Double lip seal Damper unit for volume flow rate balancing Installation manual GB en Air terminal devices AIRNAMIC TROX GmbH Heinrich Trox Platz 47...

Страница 2: ...safety at work and general safety regulations also apply Qualified staff Specialist personnel Specialist personnel are individuals who have suffi cient professional or technical training knowledge and...

Страница 3: ...ed to a supply air or extract air system by others which is typically connected to an air handling unit Air terminal devices supply cold or warm air to rooms within the stated supply air to room air t...

Страница 4: ...falling Do not move bulky items just by yourself Get help to prevent injuries and damage Storage Please note Store the product only in its original packaging Protect the product from the effects of w...

Страница 5: ...AIRNAMIC 250 is fitted with a transition piece Weights apply to the supply air variant Fig 5 AIRNAMIC R with plenum box for horizontal duct connection nominal size 250 Fig 6 AIRNAMIC R V AIRNAMIC R V...

Страница 6: ...d fixing material fixing material is not included in the supply package Refer to the technical leaflets for product weights and dimensions The air terminal devices must remain acces sible for cleaning...

Страница 7: ...hts are given in the technical leaflets Only work in pairs preferably use a lift Fig 9 Installation with plenum box or spigot 1 Fix the suspension parts such as ropes cables or metal hangers Fig 9 to...

Страница 8: ...160 and 250 Fig 14 Flush ceiling installation with spigot Diffuser face Spigot Ceiling tile Installation into ceiling tiles of thickness A1 0 5 to 30 0 mm Fig 15 Installing the transition piece 1 Whe...

Страница 9: ...between installation and commissioning cover all openings of the casing e g with plastic to protect the interior and avoid cumbersome cleaning procedures at the time of commissioning Fig 17 Installin...

Страница 10: ...18 Installing the diffuser face 1 Insert the central fixing screw Fig 18 3 on the back of the diffuser face Fig 18 2 then insert the diffuser face with the fixing screw into the plenum box Fig 18 1 2...

Страница 11: ...um box Fig 19 Bayonet fixing and fixing points 3 fixing points No tools required to fix the diffuser face nominal sizes 160 and 250 Fig 20 Installation of nominal sizes 160 and 250 Installation Air te...

Страница 12: ...Fig 21 Installation of nominal sizes 160 and 250 Installation Air terminal devices AIRNAMIC 12...

Страница 13: ...al connections if any have been correctly made Ensure that the devices have been correctly fixed and connected to the ducting For commissioning see also VDI 6022 part 1 Hy giene requirements for venti...

Страница 14: ...ly common household cleaners do not use any aggressive cleaning agents Do not use cleaning agents that contain chlorine Do not use equipment for removing stubborn contamination e g scrubbing sponges o...

Отзывы: