EN
6
Operating manual – dehumidifier TTP 5 E / TTP 10 E
Connecting the power cable / power adapter
•
Plug the cable's device plug into the device's mains
connection.
•
Plug the power adapter or power cable into a properly
fused mains socket.
Operation
•
Avoid open doors and windows.
•
After being switched on, the device operates fully
automatically.
Operating elements
10
1
No.
Designation
1
On/off switch
10
Indicator LED:
illuminated in green when the device is ready for
operation
illuminated in orange when the water tank is full or the
float is incorrectly positioned
Switching the device on
Once you have completely installed the device as described in
the Start-up chapter, you can switch it on.
Warning of electrical voltage
Do not remove the condensation tank from the device
during operation.
The device keeps running even if the condensation
tank is not inserted!
Otherwise, water may drop from the device
uncontrollably and damage the device. There is a risk
of electric shock!
1. Press the on/off switch (1).
ð
The LED at the on/off switch is illuminated in green.
ð
The fan switches on.
ð
The device starts to dehumidify.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
•
Empty the condensation tank, if need be.
•
Clean the device according to the Maintenance chapter.
•
Store the device according to the Storage chapter.
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
•
Check the power connection.
•
Check the power cable and mains plug for damages.
•
Check the on-site fusing.
•
Check the condensation tank for correct seating.
•
Check whether the condensation tank is full. The indicator
LED (10) is illuminated in orange.
•
Check the room temperature. Observe the device's
permissible operating range according to the technical
data.
•
Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.