background image

1

EN

Operating manual – dehumidifier TTP 5 E / TTP 10 E

Table of contents

Notes regarding the operating manual................................. 1

Safety ..................................................................................... 1

Information about the device................................................ 3

Transport and storage........................................................... 4

Assembly and installation..................................................... 5

Operation ............................................................................... 6

Errors and faults.................................................................... 6

Maintenance .......................................................................... 7

Technical annex................................................................... 10

Disposal ............................................................................... 10

Notes regarding the operating manual

Symbols

Warning of electrical voltage

This symbol indicates dangers to the life and health of
persons due to electrical voltage.

Warning

This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.

Caution

This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.

Notice

This signal word indicates important information (e.g.
material damage), but does not indicate hazards.

Info

Information marked with this symbol helps you to carry
out your tasks quickly and safely.

Follow the manual

Information marked with this symbol indicates that the
operating manual must be observed.

You can download the current version of the operating manual
and the EU declaration of conformity via the following link:

TTP 5 E

https://hub.trotec.com/?id=41289

TTP 10 E

https://hub.trotec.com/?id=41290

Safety

Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use!

Warning
Read all safety warnings and all instructions.

Failure to follow the warnings and instructions may
result in electric shock, fire and / or serious injury.

Save all warnings and instructions for future
reference.

This appliance can be used by children aged from
8 years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.

Do not use the device in potentially explosive rooms.

Do not use the device in aggressive atmosphere.

Set the device up in an upright and stable position.

Let the device dry out after a wet clean. Do not operate it
when wet.

Do not use the device with wet or damp hands.

Do not expose the device to directly squirting water.

Never insert any objects or limbs into the device.

Do not cover or transport the device during operation.

Do not sit on the device.

Содержание TTP 10 E

Страница 1: ...TRT BA TTP5E TTP10E TC 001 EN TTP 5 E TTP 10 E EN OPERATING MANUAL DEHUMIDIFIER ...

Страница 2: ...g link TTP 5 E https hub trotec com id 41289 TTP 10 E https hub trotec com id 41290 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save ...

Страница 3: ...n hose Discharge the collected condensate before transport and storage Do not drink it Health hazard Intended use Only use the device for keeping the room air in spatially limited areas dry whilst adhering to the technical data Intended use includes keeping the following dry small living spaces closets and shoe cabinets bookshelves pantries and storerooms small windowless bathrooms etc Improper us...

Страница 4: ...humidified cooled air is blown out The drier air thus conditioned mixes with the air in the room The humidity in the room where the device is positioned is reduced as air constantly circulates through the device Depending on the air temperature and the relative humidity the condensed water drops into the condensation tank The latter is fitted with a float to measure the filling level If the maximu...

Страница 5: ...e remaining condensate from the device and the condensation drain hose see chapter Maintenance Do not use the power cable to drag the device After transporting the device observe the following Set up the device in an upright position after transport Storage Before storing the device proceed as follows Drain the remaining condensate from the device and the condensation drain hose see chapter Mainte...

Страница 6: ...ng hazards when laying the power cable or other electric cables especially when positioning the device in the middle of the room Use cable bridges Make sure that extension cables are completely unrolled When positioning the device keep a sufficient distance to heat sources Make sure that no curtains or other objects interfere with the air flow When positioning the device particularly in wet areas ...

Страница 7: ...c shock 1 Press the on off switch 1 ð The LED at the on off switch is illuminated in green ð The fan switches on ð The device starts to dehumidify Shutdown Warning of electrical voltage Do not touch the mains plug with wet or damp hands Hold onto the mains plug while pulling the power cable out of the mains socket Empty the condensation tank if need be Clean the device according to the Maintenance...

Страница 8: ... at least 3 minutes after maintenance and repair work Only then switch the device back on Your device still does not operate correctly after these checks Please contact the customer service If necessary bring the device to an authorized specialist electrical company or to Trotec for repair Maintenance Activities required before starting maintenance Warning of electrical voltage Do not touch the ma...

Страница 9: ...ter make sure that it is undamaged and dry The air filter has to be cleaned as soon as it is dirty This is brought to light e g by a reduced capacity see chapter Errors and faults 1 Remove the air filter from the device TTP 10 E 2 Clean the filter using a slightly damp soft lint free cloth If the filter is heavily contaminated clean it with warm water mixed with a neutral cleaning agent 3 Allow th...

Страница 10: ...r Clean the tank regularly using a mild cleaning agent no detergent 6 Refit the condensation tank into the device Make sure not to damage the float when inserting or removing the condensation tank In doing so make sure that the float is positioned correctly In doing so make sure that the condensation tank is inserted correctly for otherwise the device cannot be switched back on Activities required...

Страница 11: ...cm 10 cm 10 cm 10 cm 10 cm 10 cm Weight 1 5 kg 2 kg Disposal The icon with the crossed out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life You will find collection points for free return of waste electrical and electronic equipment in your vicinity The addresses can be obtained from your mu...

Страница 12: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...