Operating Manual – Dehumidifier TTK 75 E

9

The accurate functionality of the device was tested
during production a number of times. However, if
functionality faults do occur, then check the device
according to the following list.

The device does not start:

• Check the mains power 

(230 V/1~/50 Hz).

• Check the mains plug for damages.

• Have the electrics checked by a specialist compa-

ny for cooling and air-conditioning or
by TROTEC

®

.

The device runs but forms no condensation:

• Check the condensation tank is positioned correct-

ly. Check the fill level of the condensation tank and
empty it if necessary. The condensation tank indi-
cator light must not light up.

• Check the float in the condensation tank for dam-

ages. If necessary, clean the float and condensa-
tion tank. The float must be able to move freely.

• Check the room temperature. Ensure that the de-

vice's operating range complies with the technical
data.

• Ensure that the relative humidity complies with the

technical data.

• Check that the selected humidity is realistic. The

humidity in the room must be above the selected
range. Reduce the preselected relative humidity by
turning the rotary switch (12), if necessary.

• Check the air filter is not dirty. If necessary, clean

or replace the air filter.

• From the outside, check the condenser for dirt (see

chapter Maintenance). If your condenser is dirty,
have it cleaned by a specialist company for cooling
and air-conditioning or by TROTEC

®

.

The device is loud or vibrates; condensation leaks:

• Check whether the device is standing upright and

on an even surface.

The device gets very warm, is loud or is losing
performance:

• Check the air inlets and air filter are not dirty. Re-

move external dirt.

• Check the inside of the device and especially the

fan, the fan housing, the evaporator and the con-
denser for external dirt (see chapter Maintenance).
If the inside of the device is dirty, have it cleaned
by a specialist company for cooling and air-condi-
tioning or by TROTEC

®

.

Does your device still not operate correctly after
these checks?

Bring the device to a specialist company for cooling
and air-conditioning or to TROTEC

®

 for repairs.

Errors and faults

Содержание TTK 75 E

Страница 1: ...TTK 75 E OPERATING MANUAL DEHUMIDIFIER EN TRT BA TTK75E TC 002 EN...

Страница 2: ......

Страница 3: ...tronically pro cessing duplicating or spreading the publication Subject to technical changes All rights reserved Trademarks are used without guarantee that they may be used freely and primarily follow...

Страница 4: ...ase into the condensation tray and through the integrated drain nozzle into the con densation tank 3 below This is fitted with a float to measure the fill level The device has a control panel 1 for op...

Страница 5: ...idity 30 80 Volume of airflow max 192 m h Electric connection 230 V 50 Hz Power consumption max 355 W Fuse home 10 A Condensation tank 3 l Refrigerant R410a Amount of refrigerant 160 g Weight 12 3 kg...

Страница 6: ...se the device TTK 75 E only for drying and dehumid ifying room air while adhering to and following the technical data Intended use encapsulates drying and dehumidifying living rooms bedrooms bathrooms...

Страница 7: ...ight position where it is protected from dust and direct sunlight with a plastic cover to protect it from invasive dust if necessary The storage temperature is the same as the range given for the oper...

Страница 8: ...automatic defrost is active 10 Condensation tank full indicator light Flashes once the maximum fill level of the condensation tank is reached or when the condensation tank is not installed correctly...

Страница 9: ...right to CONTINUOUS Normal operation mode In normal operation mode the device stops the dehu midification once the desired room humidity has been reached When the humidity in the rooms increases the...

Страница 10: ...pter Operating elements 2 Do not touch the mains plug with wet or damp hands 3 Remove the mains plug from the mains socket 4 Empty the condensation tank and wipe it dry with a clean cloth Check for dr...

Страница 11: ...ta Check that the selected humidity is realistic The humidity in the room must be above the selected range Reduce the preselected relative humidity by turning the rotary switch 12 if necessary Check t...

Страница 12: ...ace air filter X check for damages X check attachment screws X X carry out a test run X Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 check air inlets and outlets for dirt and f...

Страница 13: ...ned must only be carried out by specialist companies for cooling and air conditioning or by TROTEC Visual check for dirt in the inside of the device 1 Remove the air filter see chapter Cleaning the ai...

Страница 14: ...fier TTK 75 E EN Cleaning the housing and condensation tank 1 Use a soft lint free cloth for cleaning 2 Dampen the cloth with clean water Do not use sprays solvents alcohol based or abrasive cleaners...

Страница 15: ...3 Cleaning the air inlets and the air filter Caution Ensure that the air filter is not worn or damaged Before reinserting the air filter ensure that it is dry Read the chapter Maintenance intervals an...

Страница 16: ...oard 36 Fixture 7 Plate 22 Lamp assembly 37 Cover 8 Evaporator assembly 23 Knob 38 Cover 9 Condenser assembly 24 Capacitor 1 F 450 for fan motor 14 39 Humidity switch 10 Y tube 25 Fix metal 40 Sensor...

Страница 17: ...ose of the refrigerant oil mixture appropri ately and according to the national regulations in accordance with the EC Low Voltage Directive 2006 95 EC Annex III Section B and the EC Directive 2004 108...

Страница 18: ......

Страница 19: ......

Страница 20: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: