background image

2

EN

dehumidifier TTK 655 S

Table of contents

Notes regarding the instructions .......................................... 2

Safety ..................................................................................... 2

Information about the device................................................ 5

Transport and storage........................................................... 6

Assembly and installation..................................................... 7

Operation ............................................................................... 9

Available accessories.......................................................... 10

Errors and faults.................................................................. 10

Maintenance ........................................................................ 12

Technical annex................................................................... 14

Disposal ............................................................................... 19

Declaration of conformity ................................................... 19

Notes regarding the instructions

Symbols

Danger

This symbol indicates dangers to life and health of
persons due to the flammable substance R454C.

Warning of electrical voltage

This symbol indicates dangers to the life and health of
persons due to electrical voltage.

Warning

This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.

Caution

This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.

Note

This signal word indicates important information (e.g.
material damage), but does not indicate hazards.

Info

Information marked with this symbol helps you to carry
out your tasks quickly and safely.

Follow the manual

Information marked with this symbol indicates that the
instructions must be observed.

You can download the current version of the instructions and
the EU declaration of conformity via the following link:

TTK 655 S

https://hub.trotec.com/?id=41430

Safety

Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use!

Warning
Read all safety warnings and all instructions.

Failure to follow the warnings and instructions may
result in electric shock, fire and / or serious injury.

Save all warnings and instructions for future
reference.

This appliance can be used by children aged from
8 years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.

Do not use the device in potentially explosive rooms.

Do not use the device in aggressive atmosphere.

Set the device up in an upright and stable position.

Let the device dry out after a wet clean. Do not operate it
when wet or when in moist surroundings.

Do not use the device with wet or damp hands.

Do not expose the device to directly squirting water.

Never insert any objects or limbs into the device and never
use it as source of ignition.

Do not cover or transport the device during operation.

Do not sit on the device.

This appliance is not a toy! Keep away from children and
animals. Do not leave the device unattended during
operation.

Содержание TTK 655 S

Страница 1: ...TRT BA TTK655S TC2018 54 004 EN TTK 655 S EN ORIGINAL INSTRUCTIONS DEHUMIDIFIER ...

Страница 2: ...S https hub trotec com id 41430 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference T...

Страница 3: ...e in rooms where there is no source of ignition e g open flames an active gas appliance or an electric heater Please note that the refrigerant is odourless Only install the device in compliance with the national installation regulations Observe the national gas regulations Only install operate and store the device TTK 655 S in a room measuring more than 4 m2 Store the device in a way that no mecha...

Страница 4: ...ualification A corresponding repair manual is available from the manufacturer upon request Residual risks Danger Refrigerant R454C H220 Extremely flammable gas H280 Contains gas under pressure may explode if heated P210 Keep away from heat sparks open flames and other ignition sources No smoking P381 Eliminate all ignition sources if safe to do so P403 Store in a well ventilated place Warning of e...

Страница 5: ...ctor into an external container or drain Optionally the condensed water can also be discharged from the device by means of a retrofitted condensate pump see chapter Installing the condensate pump For easy operation and transport the device is fitted with an on off switch an operating hours counter a transport handle and wheels Two feet with rubber buffers prevent the device from rolling away The d...

Страница 6: ...condensation drain hose see chapter Maintenance Do not use the power cable to drag the device Do not incline the device by more than 45 for otherwise the device could be damaged Only wheel the device on a level and smooth surface Note After unpacking the device remove the two lower screws and adjust the transport handle Afterwards reinsert the screws This only needs to be carried out the very firs...

Страница 7: ...et Drain any possibly remaining condensate When the device is not being used observe the following storage conditions Only store the device in a room measuring more than 4 m2 Only position the device in rooms where there is no source of ignition e g open flames an active gas appliance or an electric heater dry and protected from frost and heat in an upright position where it is protected from dust...

Страница 8: ...cially when positioning the device in the middle of the room Use cable bridges Make sure that extension cables are completely unrolled When positioning the device keep a sufficient distance to heat sources Make sure that no curtains or other objects interfere with the air flow When positioning the device particularly in wet areas secure it locally with an RCD residual current device which complies...

Страница 9: ...sure that the condensation drain hose is properly connected to the device and is free of damage 2 Position a sufficiently large container at least 20 litres we recommend a 60 litre mortar tub beside the device and insert the hose end Check the filling level of the container regularly 3 Make sure that the condensation drain hose is installed with a continuous decline 4 Insert the mains plug into a ...

Страница 10: ...onto the mains plug while pulling the power cable out of the mains socket Clean the device according to the Maintenance chapter Store the device according to the Storage chapter Available accessories Warning Only use accessories and additional equipment specified in the instructions Using insertion tools or accessories other than those specified in the instructions may cause a risk of injury Desig...

Страница 11: ...have it cleaned by a specialist company for cooling and air conditioning or by Trotec Your device still does not operate correctly after these checks Please contact the customer service If necessary bring the device to a specialist company for cooling and air conditioning or to Trotec for repair Error codes The Status LED 15 can indicate the following statuses during operation Error message Meanin...

Страница 12: ...and or drain hose X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign objects and clean if necessary Clean the exterior Visually check the inside of the device for dirt Check the air filter for dirt and foreign objects and clean or replace if necessary Replace the air filter Chec...

Страница 13: ...d place The entire refrigerant circuit is a maintenance free hermetically sealed system and may only be maintained or repaired by specialist companies for cooling and air conditioning or by Trotec Safety signs and labels on the device Check the safety signs and labels attached to the device at regular intervals Replace illegible safety signs Cleaning the housing Clean the housing with a soft damp ...

Страница 14: ...enance If you want to continue using the device Reconnect the device to the mains If you do not intend to use the device for a considerable time Store the device according to the Storage chapter Technical annex Technical data Parameter Value Model TTK 655 S Dehumidification performance 30 C 80 RH 91 l 24 h Dehumidification performance max 150 l 24 h Operating range temperature 5 32 C Operating ran...

Страница 15: ...IGH LEVEL FLOAT SWITCH LOW LEVEL FLOAT SWITCH PURGE SWITCH Black Black Blue Brown Green Yellow PLUG Brown Red Black Motor Water Pump Optional P F C NA CC NF N J9 JP11 J5 PCB Status 2 C NTC 10kÙ NC contact NO contact SHUNT 3 2 1 Time Counter Standard M2 M2 M1 M1 Y Y L RC H N J7 3 C 32 C NTC 10kÙ S1 0 1 R R E Earthing M2 Fan motor N Common Line Y Two Way Valve L Line RC Running Capacitor S1 On Off S...

Страница 16: ...7 3 C 32 C 2 C NTC 10kÙ NTC 10kÙ NC contact NO contact 4 P SHUNT 3 2 1 S1 0 1 Time Energy Counter HE Iavg 5A N Lout Lin M2 M2 M1 M1 Y Y RC F C NA CC NF N Counter counting energy and time downstream the main switch Wiring diagram with condensates pump reseting the PCB 220 240V 50Hz 220 240V 50Hz PCB Status R R E Earthing M2 Fan motor N Common Line Y Two Way Valve L Line RC Running Capacitor S1 On O...

Страница 17: ...position numbers of the spare parts differ from those describing the positions of the components mentioned in these instructions 5 3 37 40 38 29 46 23 6 20 39 33 41 36 34 11 13 12 47 20 15 4 18 19 21 31 1 2 24 22 48 16 17 7 44 43 8 10 35 32 30 27 28 25 26 14 42 45 9 ...

Страница 18: ... 22 Running capacitor 38 Time counter 7 Left side panel 23 Heat exchanger 39 Hygrostat 8 Dummy panel for optional condensates pump 24 Water pan 40 Humidistat knob 9 1 4 turn lock 25 Hose fitting 41 Electronic controller 10 Structural foot 26 Hidraulic Plug 42 Electronic controller status LED 11 Rubber feet 27 Defrost valve 43 Defrost sensor 12 Wheels axe 28 Defrost valve coil 44 Ambient temperatur...

Страница 19: ...rotec com id 41430 Declaration of conformity in accordance with the EC Machinery Directive 2006 42 EC Annex II Part 1 Section A Herewith we Trotec GmbH declare that the machinery designated below was developed constructed and produced in compliance with the requirements of the EC Machinery Directive in the version 2006 42 EC Product model product TTK 655 S Product type dehumidifier Year of manufac...

Страница 20: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...