background image

14

EN

dehumidifier TTK 655 S

Cleaning the air filter

Note

Ensure that the air filter is not worn or damaged. The
corners and edges of the air filter must not be
deformed or rounded. Before reinserting the air filter,
make sure that it is undamaged and dry!

The air filter has to be cleaned as soon as it is dirty. This is
brought to light e.g. by a reduced capacity (see chapter Errors
and faults).

1. Remove the air filter from the device.

2. Clean the filter using a slightly damp, soft, lint-free cloth. If

the filter is heavily contaminated, clean it with warm water
mixed with a neutral cleaning agent.

3. Allow the filter to dry completely. Do not insert a wet filter

into the device!

4. Reinsert the air filter into the device.

Activities required after maintenance

If you want to continue using the device:

Reconnect the device to the mains.

If you do not intend to use the device for a considerable time:

Store the device according to the Storage chapter.

Technical annex

Technical data

Parameter

Value

Model

TTK 655 S

Dehumidification performance
@ 30 °C / 80 % RH

91 l / 24 h

Dehumidification performance,
max.

150 l / 24 h

Operating range (temperature) 5 – 32 °C

Operating range (relative
humidity)

50 % – 90 % RH

Max. permissible pressure

1.8 MPa

Pressure suction side

0.5 MPa

Pressure outlet side

1.8 MPa

Air volume flow

1000 m³/h

Mains connection

220-240 V ~ 50 Hz

Power consumption, max.

1.9 kW

Nominal current

8.6 A

Refrigerant

R454C

Amount of refrigerant

1050 g

GWP factor

146

CO

2

 equivalent

0.15 t

Sound pressure level LpA (1 m;
complies with 
DIN 45635-01-KL3)

56 dB(A)

Dimensions (length x width x
height)

620 x 515 x 858 mm

Minimum distance to walls and
other objects

A: top:

B: rear:

C: side:

D: front:

50 cm
50 cm
50 cm
50 cm

Weight

55 kg

Содержание TTK 655 S

Страница 1: ...TRT BA TTK655S TC2018 54 004 EN TTK 655 S EN ORIGINAL INSTRUCTIONS DEHUMIDIFIER ...

Страница 2: ...S https hub trotec com id 41430 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference T...

Страница 3: ...e in rooms where there is no source of ignition e g open flames an active gas appliance or an electric heater Please note that the refrigerant is odourless Only install the device in compliance with the national installation regulations Observe the national gas regulations Only install operate and store the device TTK 655 S in a room measuring more than 4 m2 Store the device in a way that no mecha...

Страница 4: ...ualification A corresponding repair manual is available from the manufacturer upon request Residual risks Danger Refrigerant R454C H220 Extremely flammable gas H280 Contains gas under pressure may explode if heated P210 Keep away from heat sparks open flames and other ignition sources No smoking P381 Eliminate all ignition sources if safe to do so P403 Store in a well ventilated place Warning of e...

Страница 5: ...ctor into an external container or drain Optionally the condensed water can also be discharged from the device by means of a retrofitted condensate pump see chapter Installing the condensate pump For easy operation and transport the device is fitted with an on off switch an operating hours counter a transport handle and wheels Two feet with rubber buffers prevent the device from rolling away The d...

Страница 6: ...condensation drain hose see chapter Maintenance Do not use the power cable to drag the device Do not incline the device by more than 45 for otherwise the device could be damaged Only wheel the device on a level and smooth surface Note After unpacking the device remove the two lower screws and adjust the transport handle Afterwards reinsert the screws This only needs to be carried out the very firs...

Страница 7: ...et Drain any possibly remaining condensate When the device is not being used observe the following storage conditions Only store the device in a room measuring more than 4 m2 Only position the device in rooms where there is no source of ignition e g open flames an active gas appliance or an electric heater dry and protected from frost and heat in an upright position where it is protected from dust...

Страница 8: ...cially when positioning the device in the middle of the room Use cable bridges Make sure that extension cables are completely unrolled When positioning the device keep a sufficient distance to heat sources Make sure that no curtains or other objects interfere with the air flow When positioning the device particularly in wet areas secure it locally with an RCD residual current device which complies...

Страница 9: ...sure that the condensation drain hose is properly connected to the device and is free of damage 2 Position a sufficiently large container at least 20 litres we recommend a 60 litre mortar tub beside the device and insert the hose end Check the filling level of the container regularly 3 Make sure that the condensation drain hose is installed with a continuous decline 4 Insert the mains plug into a ...

Страница 10: ...onto the mains plug while pulling the power cable out of the mains socket Clean the device according to the Maintenance chapter Store the device according to the Storage chapter Available accessories Warning Only use accessories and additional equipment specified in the instructions Using insertion tools or accessories other than those specified in the instructions may cause a risk of injury Desig...

Страница 11: ...have it cleaned by a specialist company for cooling and air conditioning or by Trotec Your device still does not operate correctly after these checks Please contact the customer service If necessary bring the device to a specialist company for cooling and air conditioning or to Trotec for repair Error codes The Status LED 15 can indicate the following statuses during operation Error message Meanin...

Страница 12: ...and or drain hose X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign objects and clean if necessary Clean the exterior Visually check the inside of the device for dirt Check the air filter for dirt and foreign objects and clean or replace if necessary Replace the air filter Chec...

Страница 13: ...d place The entire refrigerant circuit is a maintenance free hermetically sealed system and may only be maintained or repaired by specialist companies for cooling and air conditioning or by Trotec Safety signs and labels on the device Check the safety signs and labels attached to the device at regular intervals Replace illegible safety signs Cleaning the housing Clean the housing with a soft damp ...

Страница 14: ...enance If you want to continue using the device Reconnect the device to the mains If you do not intend to use the device for a considerable time Store the device according to the Storage chapter Technical annex Technical data Parameter Value Model TTK 655 S Dehumidification performance 30 C 80 RH 91 l 24 h Dehumidification performance max 150 l 24 h Operating range temperature 5 32 C Operating ran...

Страница 15: ...IGH LEVEL FLOAT SWITCH LOW LEVEL FLOAT SWITCH PURGE SWITCH Black Black Blue Brown Green Yellow PLUG Brown Red Black Motor Water Pump Optional P F C NA CC NF N J9 JP11 J5 PCB Status 2 C NTC 10kÙ NC contact NO contact SHUNT 3 2 1 Time Counter Standard M2 M2 M1 M1 Y Y L RC H N J7 3 C 32 C NTC 10kÙ S1 0 1 R R E Earthing M2 Fan motor N Common Line Y Two Way Valve L Line RC Running Capacitor S1 On Off S...

Страница 16: ...7 3 C 32 C 2 C NTC 10kÙ NTC 10kÙ NC contact NO contact 4 P SHUNT 3 2 1 S1 0 1 Time Energy Counter HE Iavg 5A N Lout Lin M2 M2 M1 M1 Y Y RC F C NA CC NF N Counter counting energy and time downstream the main switch Wiring diagram with condensates pump reseting the PCB 220 240V 50Hz 220 240V 50Hz PCB Status R R E Earthing M2 Fan motor N Common Line Y Two Way Valve L Line RC Running Capacitor S1 On O...

Страница 17: ...position numbers of the spare parts differ from those describing the positions of the components mentioned in these instructions 5 3 37 40 38 29 46 23 6 20 39 33 41 36 34 11 13 12 47 20 15 4 18 19 21 31 1 2 24 22 48 16 17 7 44 43 8 10 35 32 30 27 28 25 26 14 42 45 9 ...

Страница 18: ... 22 Running capacitor 38 Time counter 7 Left side panel 23 Heat exchanger 39 Hygrostat 8 Dummy panel for optional condensates pump 24 Water pan 40 Humidistat knob 9 1 4 turn lock 25 Hose fitting 41 Electronic controller 10 Structural foot 26 Hidraulic Plug 42 Electronic controller status LED 11 Rubber feet 27 Defrost valve 43 Defrost sensor 12 Wheels axe 28 Defrost valve coil 44 Ambient temperatur...

Страница 19: ...rotec com id 41430 Declaration of conformity in accordance with the EC Machinery Directive 2006 42 EC Annex II Part 1 Section A Herewith we Trotec GmbH declare that the machinery designated below was developed constructed and produced in compliance with the requirements of the EC Machinery Directive in the version 2006 42 EC Product model product TTK 655 S Product type dehumidifier Year of manufac...

Страница 20: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Отзывы: