Operating Instructions Dehumidifier TTK 650 S
B-5
EN
The unit is very loud or has started to vibrate;
condensate is running out of the unit:
• Check to ensure that the unit is standing on a flat and level surface.
• Have the condensate tray and the connecting piece checked to see
if they are heavily soiled.
Please contact an authorised dealer if the unit still does not work properly despite
the checks that you have carried out.
Any work that has to be carried out on the refrigerant unit
or the electrical circuits may only be performed by an
authorised and certified specialist dealer !
12. Technical Data
Temperature operating range 5 - 32 °C
Relative humidity operating range 40 - 90 % RH
Dehumidification performance 24 h max. 150 litres
Dehumidification performance 24 h (at 30 °C / 80 % RH) 123 litres
Air flow rate max. 1,480 m³/h
Refrigerant R-407C
Refrigerant quantity 1.15 kg
Connection voltage 230 V / 50 Hz
Nominal current max. 6 A
Power input max. 1.8 kW
Noise level LpA 1m
1)
56 dB (A)
Length * 540 mm
Width * 640 mm
Height * 850 mm
Weight 50 kg
1)
Noise measurement DIN 45635 - 01 - KL 3
* without handle and wheels
Cleaning the condensator and the evaporator
Because these components are only accessible when the unit’s housing has
been opened, both parts may only be cleaned by an authorised dealer !
• The condensator and the evaporator may only be cleaned with a soft brush
or by blowing or sucking air. Do NOT spray or clean with water.
• The evaporator fins and the parts themselves are very sensitive and
can be easily bent or otherwise damaged.
• The interior surfaces of the unit, the condensate tray, the fan and
the fan housing must be cleaned carefully.
• It must be ensured that the parts that were previously dismantled
are all properly put back together again.
• Check the unit to ensure that it works properly and check the
electrical system to ensure that is safe.
Important information regarding recycling !
The unit is operated with the environmentally-friendly, ozone-neutral refrigerant
R-407C. The refrigerant /oil mixture in the unit must be disposed of in a safe
way in accordance with local and national regulations and guidelines.
Please dispose of this appliance in a manner appropriate to the
relevant legal requirements at the end of its product life.
11. Troubleshooting
The unit was subjected to stringent testing during production and before it left
our premises. Please check the product you have bought using the list below
should you encounter any problems.
The unit will not start up:
• Check the mains power supply. 230 V / 1~ / 50 Hz.
• Check the main fuses in the building.
• Check the mains plug to make sure that it not damaged.
The unit is running but there is no condensate forming:
• Check the room temperature. The unit’s operating range is
between 5 and 32 °C.
• Check the relative humidity. It must be at least 40 % RH.
• Check the mode the unit is in. The relative humidity in the room which
the dehumidifier has been installed in must be higher than the selected
value. Turn the control dial all the way round to maximum postion,
ie. non-stop mode if necessary
(see fig. D.5)
.
• Check the air intake filter to see that it is not heavily soiled or damaged.
Clean or replace if necessary.
• The exchanger fins may have to be checked to see if they are heavily
soiled. Because these components are only accessible when the unit’s
housing has been opened, the parts may only be cleaned by an
authorised and certified specialist dealer !
Disconnect the plug from the mains BEFORE any work
is a carried out on the unit !