Description of the device
This device uses the principle of condensation to au-
tomatically dehumidify rooms.
The fan sucks damp room air through the air inlet (8),
the air filter (10), the evaporator and to the condenser
located behind it. The air is cooled at the cold evapo-
rator until it is below the dew point. Water vapour con-
tained in the room air precipitates on the evaporator
fins as either condensation or frost. The dehumidified,
cooled air is rewarmed at the condenser and blown
out at a temperature of approx. 5 °C above room tem-
perature. The drier air which is prepared in this way
mixes with the air in the room. The humidity in the
room where the device is positioned is reduced as air
constantly circulates through the device. Depending
on the air temperature and the relative humidity, the
condensed water either drops continuously or only
during the defrost phase into the condensation tray
and through the integrated drain nozzle into the con-
densation tank (4) below. This is fitted with a float to
measure the fill level. The device has a control
panel (1) for operating and controlling the functions.
Once the maximum fill level of the condensation
tank (4) is reached, the condensation tank indicator
light ("FULL") on the control panel (1) flashes red. The
device switches off. The condensation tank indicator
light only goes out again once the emptied condensa-
tion tank (4) is reinserted. The condensed water can
be diverted by attaching a hose at the condensation
plug (6). The device can reduce the relative humidity
of a room by up to approx. 50 %. It provides additional
assistance for drying wet washing or clothing in living
or working spaces. Because of the heat radiation
which is tied up in operation, the room temperature
can rise by approx. 1-4 °C.
Device depiction
Information about the device
No.
Operating element
1
control panel
2
carry handle
3
air outlet
4
condensation tank
5
carry handle
6
condensation plug
7
power cable coil
8
air inlet
9
wheels
10
air filter
2
3
1
4
8
7
6
5
10
9