background image

EN

8

Operating manual – dehumidifier TTK 30 E

Colour LED for current room humidity

Regardless of the operating mode, the colour LED indicates the
current relative room humidity by means of 3 different colours.

LED colour

Meaning

Blue

Relative room humidity below
55 %

Green

Optimal relative room humidity
between 55 % and 70 %

Red

Illuminated: relative room
humidity above 70 %
Flashes: water tank full or not
inserted correctly
(accompanied by an acoustic
signal)

Setting the timer

Using the timer function, the device can be switched off
automatically after a preset number of hours.
The number of hours can range from 1 to 24 and can be
adjusted in increments of 1 h.

Note

Do not leave the operating device unattended in a
freely accessible room with an activated timer.

ü

The device is switched on.

1. Press the 

TIMER

 button (16).

ð

The number of hours flashes in the segment
display (12).

2. Press the arrow buttons (18, 19) to set the desired number

of hours.

3. Wait for approx. 5 seconds in order to save the setting.

ð

The 

Timer

 indication (11) is illuminated.

ð

The relative room humidity is indicated in the segment
display (12) again.

ð

The device switches off after the set period of time.

Memory function

The device memorizes the last selected operating mode, and in

dehumidification

 mode (13) also the set room humidity,

provided the device is switched off manually by pressing the

ON/OFF

 button (15) and remains connected to the mains.

During short power failures, the device does 

not

 memorize the

settings. The device starts in 

automatic

 mode (13) in this case.

Child lock

1. Press the arrow buttons (18, 19) simultaneously for

approx. 3 seconds to enable the child lock.

ð

An acoustic signal is emitted.

ð

The 

child lock

 indication (20) is illuminated.

2. Press the arrow buttons (18, 19) simultaneously for

approx. 3 seconds to disable the child lock.

ð

An acoustic signal is emitted.

ð

The 

child lock

 indication (20) disappears.

Auto stop function

If the water tank is full, not inserted correctly or the relative
room humidity has been reached, the device will stop
automatically.

Operation with hose attached to the condensation
connection

For continuous operation or unattended dehumidification, please
connect the supplied condensation drain hose to the device.

ü

A suitable hose (diameter: 17 mm) is ready for use.

ü

The device is switched off.

1. Remove the sealing cap from the hose connection.

Содержание TTK 30 E

Страница 1: ...TRT BA TTK30E TC 002 EN TTK 30 E EN OPERATING MANUAL DEHUMIDIFIER...

Страница 2: ...e Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in...

Страница 3: ...lso be used as a kind of clothes dryer to dry wet laundry Intended use comprises dehumidifying and drying living rooms bedrooms bathrooms and basements laundries holiday homes camper vans boats mainta...

Страница 4: ...reduced as air constantly circulates through the device Depending on the air temperature and the relative humidity the condensed water either drops continuously or only during the defrost phase throu...

Страница 5: ...wer cable to drag the device After transporting the device observe the following Set up the device in an upright position after transport Leave the device to rest for 12 to 24 hours so the refrigerant...

Страница 6: ...electric cables especially when positioning the device in the middle of the room Use cable bridges Make sure that extension cables are unrolled completely When positioning the device keep a sufficien...

Страница 7: ...ontinuous operation Laundry drying function Ventilation 15 ON OFF button Power button Switches the device on or off 16 TIMER button Starts programming for the timer function 17 FAN button Setting the...

Страница 8: ...s the arrow buttons 18 19 until the LED for automatic mode 13 starts flashing 3 Then press the MODE button 14 again Automatic mode is selected Continuous operation The device dehumidifies the air cons...

Страница 9: ...ndicated in the segment display 12 again The device switches off after the set period of time Memory function The device memorizes the last selected operating mode and in dehumidification mode 13 also...

Страница 10: ...rom the mains socket The Defrost indication 22 is illuminated during automatic defrosting Drying laundry In addition the device may also be used as a kind of clothes dryer to dry wet laundry in living...

Страница 11: ...om the outside check the condenser for dirt see chapter Maintenance If the condenser is dirty have it cleaned by a specialist company or by Trotec The device might carry out an automatic defrost Durin...

Страница 12: ...onths at least annually Check air inlets and outlets for dirt and foreign objects and clean if necessary X X Clean the exterior X X Visually check the inside of the device for dirt X X Check the air f...

Страница 13: ...ce for dirt Check the air filter for dirt and foreign objects and clean or replace if necessary Replace the air filter Check for damage Check the attachment screws Test run Remarks Empty the condensat...

Страница 14: ...the inside of the device for dirt 1 Remove the air filter 2 Use a torch to illuminate the openings of the device 3 Check the inside of the device for dirt 4 If you see a thick layer of dust have the i...

Страница 15: ...filter into the device Emptying the condensation tank If the condensation tank is full or not inserted correctly an acoustic signal will be emitted Furthermore the colour LED for the current room hum...

Страница 16: ...frigerant R 134a Amount of refrigerant 50 g GWP factor 1 430 CO2 equivalent 0 07 t Water tank 2 2 l Sound pressure level 45 dB A Dimensions length x width x height 220 x 280 x 415 mm Minimum distance...

Страница 17: ......

Страница 18: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: