8
Operating manual – dehumidifier TTK 30 E
Colour LED for current room humidity
Regardless of the operating mode, the colour LED indicates the
current relative room humidity by means of 3 different colours.
LED colour
Meaning
Blue
Relative room humidity below
55 %
Green
Optimal relative room humidity
between 55 % and 70 %
Red
Illuminated: relative room
humidity above 70 %
Flashes: water tank full or not
inserted correctly
(accompanied by an acoustic
signal)
Setting the timer
Using the timer function, the device can be switched off
automatically after a preset number of hours.
The number of hours can range from 1 to 24 and can be
adjusted in increments of 1 h.
Note
Do not leave the operating device unattended in a
freely accessible room with an activated timer.
ü
The device is switched on.
1. Press the
TIMER
button (16).
ð
The number of hours flashes in the segment
display (12).
2. Press the arrow buttons (18, 19) to set the desired number
of hours.
3. Wait for approx. 5 seconds in order to save the setting.
ð
The
Timer
indication (11) is illuminated.
ð
The relative room humidity is indicated in the segment
display (12) again.
ð
The device switches off after the set period of time.
Memory function
The device memorizes the last selected operating mode, and in
dehumidification
mode (13) also the set room humidity,
provided the device is switched off manually by pressing the
ON/OFF
button (15) and remains connected to the mains.
During short power failures, the device does
not
memorize the
settings. The device starts in
automatic
mode (13) in this case.
Child lock
1. Press the arrow buttons (18, 19) simultaneously for
approx. 3 seconds to enable the child lock.
ð
An acoustic signal is emitted.
ð
The
child lock
indication (20) is illuminated.
2. Press the arrow buttons (18, 19) simultaneously for
approx. 3 seconds to disable the child lock.
ð
An acoustic signal is emitted.
ð
The
child lock
indication (20) disappears.
Auto stop function
If the water tank is full, not inserted correctly or the relative
room humidity has been reached, the device will stop
automatically.
Operation with hose attached to the condensation
connection
For continuous operation or unattended dehumidification, please
connect the supplied condensation drain hose to the device.
ü
A suitable hose (diameter: 17 mm) is ready for use.
ü
The device is switched off.
1. Remove the sealing cap from the hose connection.
Содержание TTK 30 E