Table of contents

Notes regarding the operating manual................................. 1

Safety ..................................................................................... 1

Information about the device................................................ 3

Transport and storage........................................................... 4

Assembly and installation..................................................... 5

Operation ............................................................................... 6

Errors and faults.................................................................. 10

Maintenance ........................................................................ 11

Technical annex................................................................... 15

Disposal ............................................................................... 15

Notes regarding the operating manual

Symbols

Warning of electrical voltage

This symbol indicates dangers to the life and health of
persons due to electrical voltage.

Warning

This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.

Caution

This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.

Note

This signal word indicates important information (e.g.
material damage), but does not indicate hazards.

Info

Information marked with this symbol helps you to carry
out your tasks quickly and safely.

Follow the manual

Information marked with this symbol indicates that the
operating manual must be observed.

You can download the current version of the operating manual
and the EU declaration of conformity via the following link:

TTK 30 E

https://hub.trotec.com/?id=40824

Safety

Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use!

Warning
Read all safety warnings and all instructions.

Failure to follow the warnings and instructions may
result in electric shock, fire and / or serious injury.

Save all warnings and instructions for future
reference.

This appliance can be used by children aged from
8 years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.

Do not use the device in potentially explosive rooms.

Do not use the device in aggressive atmosphere.

Set the device up in an upright and stable position.

Let the device dry out after a wet clean. Do not operate it
when wet.

Do not use the device with wet or damp hands.

Do not expose the device to directly squirting water.

Never insert any objects or limbs into the device.

Do not cover or transport the device during operation.

Do not sit on the device.

This appliance is not a toy! Keep away from children and
animals. Do not leave the device unattended during
operation.

Check accessories and connection parts for possible
damage prior to every use of the device. Do not use any
defective devices or device parts.

Содержание TTK 30 E

Страница 1: ...TRT BA TTK30E TC 002 EN TTK 30 E EN OPERATING MANUAL DEHUMIDIFIER...

Страница 2: ...e Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in...

Страница 3: ...lso be used as a kind of clothes dryer to dry wet laundry Intended use comprises dehumidifying and drying living rooms bedrooms bathrooms and basements laundries holiday homes camper vans boats mainta...

Страница 4: ...reduced as air constantly circulates through the device Depending on the air temperature and the relative humidity the condensed water either drops continuously or only during the defrost phase throu...

Страница 5: ...wer cable to drag the device After transporting the device observe the following Set up the device in an upright position after transport Leave the device to rest for 12 to 24 hours so the refrigerant...

Страница 6: ...electric cables especially when positioning the device in the middle of the room Use cable bridges Make sure that extension cables are unrolled completely When positioning the device keep a sufficien...

Страница 7: ...ontinuous operation Laundry drying function Ventilation 15 ON OFF button Power button Switches the device on or off 16 TIMER button Starts programming for the timer function 17 FAN button Setting the...

Страница 8: ...s the arrow buttons 18 19 until the LED for automatic mode 13 starts flashing 3 Then press the MODE button 14 again Automatic mode is selected Continuous operation The device dehumidifies the air cons...

Страница 9: ...ndicated in the segment display 12 again The device switches off after the set period of time Memory function The device memorizes the last selected operating mode and in dehumidification mode 13 also...

Страница 10: ...rom the mains socket The Defrost indication 22 is illuminated during automatic defrosting Drying laundry In addition the device may also be used as a kind of clothes dryer to dry wet laundry in living...

Страница 11: ...om the outside check the condenser for dirt see chapter Maintenance If the condenser is dirty have it cleaned by a specialist company or by Trotec The device might carry out an automatic defrost Durin...

Страница 12: ...onths at least annually Check air inlets and outlets for dirt and foreign objects and clean if necessary X X Clean the exterior X X Visually check the inside of the device for dirt X X Check the air f...

Страница 13: ...ce for dirt Check the air filter for dirt and foreign objects and clean or replace if necessary Replace the air filter Check for damage Check the attachment screws Test run Remarks Empty the condensat...

Страница 14: ...the inside of the device for dirt 1 Remove the air filter 2 Use a torch to illuminate the openings of the device 3 Check the inside of the device for dirt 4 If you see a thick layer of dust have the i...

Страница 15: ...filter into the device Emptying the condensation tank If the condensation tank is full or not inserted correctly an acoustic signal will be emitted Furthermore the colour LED for the current room hum...

Страница 16: ...frigerant R 134a Amount of refrigerant 50 g GWP factor 1 430 CO2 equivalent 0 07 t Water tank 2 2 l Sound pressure level 45 dB A Dimensions length x width x height 220 x 280 x 415 mm Minimum distance...