Operating manual – dehumidifier TTK 110 HEPA

Residual risks

Warning of electrical voltage

Work on the electrical components must only be
carried out by an authorised specialist company!

Warning of electrical voltage

Before any work on the device, remove the mains plug
from the mains socket!
Hold onto the mains plug while pulling the power cable
out of the mains socket.

Warning

Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!

Warning

The device is not a toy and does not belong in the
hands of children.

Warning

Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.

Notice

Do not operate the device without an inserted air filter!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.

Behaviour in the event of an emergency

1. In an emergency, disconnect the device from the mains

feed-in: Switch the device off and disconnect the power
cable from the mains socket. Hold onto the mains plug
while doing so.

2. Do not reconnect a defective device to the mains.

Information about the device

Description of the device

The device has a function for air purification that is active in

powerful dehumidification

automatic

 and 

laundry drying

 mode

and enables HEPA air purification with an efficiency of 99.97 %,
thus filtering out pollen, viruses, dust mite residue, mould
fungus spores and other allergens.
Moreover, the device has an ionisation function that can be
switched on in addition. The released ions remove pollen, dust,
viruses and bacteria from the room air. Thanks to this air
purification method, the quality of the room air can be
additionally improved.

Another feature is the device's self-cleaning function. This
function serves to dry the interior of the device in order to
prevent the formation of mould or similar inside the device due
to residual moisture.
The device uses the principle of condensation to automatically
dehumidify rooms.
The fan sucks damp room air through the air inlet, the air filter,
the evaporator and to the condenser located behind it. The air is
cooled at the cold evaporator until it is below the dew point.
Water vapour contained in the room air precipitates on the
evaporator fins as condensation or rime. The dehumidified,
cooled air is slightly warmed at the condenser and blown out
again. The drier air thus conditioned mixes with the air in the
room. The humidity in the room where the device is positioned
is reduced as air constantly circulates through the device.
Depending on the air temperature and the relative humidity, the
condensed water either drops continuously or only during the
defrost phase through the integrated drain nozzle into the
condensation tank below. It is fitted with a float to measure the
filling level.
The device has a control panel for operating and controlling the
functions.
Once the maximum filling level of the condensation tank is
reached or in case the condensation tank is not installed
correctly, the condensation tank indicator light (see chapter
Operating elements) on the control panel is illuminated. The
device switches off. The condensation tank indicator light only
goes out again once the emptied condensation tank is
reinserted.
Optionally, the condensed water can be drained by attaching a
hose at the condensation connection.
The device can reduce the relative humidity of a room to approx.
40 %.
The device provides additional assistance for drying wet laundry
or clothing in living or working spaces.
Because of the heat radiation generated during operation, the
room temperature may rise slightly.

Содержание TTK 110 HEPA

Страница 1: ...TRT BA TTK110HEPA TC 002 EN TTK 110 HEPA EN OPERATING MANUAL DEHUMIDIFIER...

Страница 2: ...r using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructi...

Страница 3: ...Ensure that the side of the device where the air inlet is found is kept free of dirt and loose objects Only transport the device in an upright position with an emptied condensation tank or drain hose...

Страница 4: ...air can be additionally improved Another feature is the device s self cleaning function This function serves to dry the interior of the device in order to prevent the formation of mould or similar in...

Страница 5: ...he following Set up the device in an upright position after transport Leave the device to rest for 12 24 hours so the refrigerant can accumulate within the compressor Wait 12 24 hours before switching...

Страница 6: ...ectric cables especially when positioning the device in the middle of the room Use cable bridges Make sure that extension cables are completely unrolled When positioning the device keep a sufficient d...

Страница 7: ...rent room temperature Indicates the number of hours of the activated timer ON is displayed if the timer for automatic switch on is active OFF is displayed if the timer for automatic switch off is acti...

Страница 8: ...d The fan speed cannot be changed The compressor switches off automatically once the desired relative room humidity has been reached The fan keeps running 1 Press the MODE button 23 until the indicati...

Страница 9: ...button 23 until the indication for the ventilation indication 19 appears on the display 2 Press the HUMIDITY button 34 to select low or high fan speed Night mode Night mode can be switched on in all o...

Страница 10: ...setting The characters OFF and the number of hours left until switch off appear on the temperature and timer indication 18 The timer setting equals the desired number of hours The device switches off...

Страница 11: ...ses when released 37 36 5 With the other hand push one end of the hose onto the hose connection 37 37 6 Let go of the fastener 36 7 Refit the condensation tank into the device Make sure not to damage...

Страница 12: ...production If malfunctions occur nonetheless check the device according to the following list The device does not start Check the power connection Check the power cable and mains plug for damages Che...

Страница 13: ...mode If the device is in air purification mode and the HEPA filter is not inserted the fan will not start Insert the HEPA filter in air purification mode see Replacing the HEPA filter The device gets...

Страница 14: ...drain hose X Check the air inlets and outlets for dirt and foreign objects and clean if necessary X X Clean the exterior X X Visually check the inside of the device for dirt X X Check the air filter f...

Страница 15: ...irt Check the air filter for dirt and foreign objects and clean or replace if necessary Replace the air filter Check the HEPA filter for dirt and foreign objects and clean or replace if necessary Repl...

Страница 16: ...de of the device cleaned by a specialist company for cooling and air conditioning or by Trotec 5 Put the air filter back in Refrigerant circuit The entire refrigerant circuit is a maintenance free her...

Страница 17: ...that it is undamaged and dry The air filter has to be cleaned as soon as it is dirty This is brought to light e g by a reduced capacity see chapter Errors and faults 1 Remove the air filter from the...

Страница 18: ...ondensation tank In doing so make sure that the float is positioned correctly In doing so make sure that the condensation tank is inserted correctly for otherwise the device cannot be switched back on...

Страница 19: ...Sensor BN BU YE GN GN YE GN GN RD Capacitor BU BU BN RD BK RD BK WH BU BU BN WH BK ELECTRIC CIRCUIT DIAGRAM YDH CN1 CN9 PH CN4 CN5 PG Water RT1 RD WH BU Photodiode Photodiode Disposal The icon with t...

Страница 20: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...