background image

9

EN

Operating manual – dehumidifier TTK 110 HEPA

Setting the timer

The timer can be set in all operating modes.
The timer has two modes of operation:

automatic switch-on upon expiry of a preset number of
hours.

automatic switch-off upon expiry of a preset number of
hours.

The number of hours can range from 1 to 24 and can be
adjusted in increments of 1 h.

Notice

Do not leave the operating device unattended in a
freely accessible room with an activated timer.

Automatic switch-on

1. Switch off the device.
2. Press the 

TIMER

 button (33) several times until the desired

number of hours is displayed on the 

temperature and timer

indication (18).

ð

The number of hours flashes on the 

temperature and

timer

 indication (18).

3. Wait for approx. 5 seconds in order to save the setting.
4. Press the 

MODE

 button (23) to select the operating mode

in which the device shall start up.

ð

The characters 

ON

 and the number of hours left until

switch-on appear on the 

temperature and timer

indication (18).

ð

The timer setting equals the desired number of hours.

ð

The device starts in the previously selected operating mode
after the set time has elapsed.

Notes regarding automatic switch-on:

Pressing the 

POWER

 button (22) deactivates the automatic

switch-on function.

Automatic switch-off

ü

The device is switched on.

1. Press the 

TIMER

 button (33) several times until the desired

number of hours is displayed on the 

temperature and timer

indication (18).

ð

The number of hours flashes on the 

temperature and

timer

 indication (18).

2. Wait for approx. 5 seconds in order to save the setting.

ð

The characters 

OFF

 and the number of hours left until

switch-off appear on the 

temperature and timer

indication (18).

ð

The timer setting equals the desired number of hours.

ð

The device switches off after the set period of time.

Memory function

During short power failures, the device memorizes the
programmed nominal value for the humidity level, the timer and
the operating mode setting.

Auto stop function

If the water tank is full, not inserted correctly or the set room
humidity has been reached, the device will stop automatically.

Child lock

The child lock can be activated both during operation and in
standby mode.

1. Press the 

MODE

 button (23) for approx. 2 seconds.

ð

The child lock is activated.

ð

The 

child lock

 indication (16) appears on the display.

2. Press the 

MODE

 button (23) for approx. 2 seconds once

again.

ð

The child lock is deactivated.

ð

The 

child lock

 indication (16) disappears.

Swing function

Using the swing function, you can adjust the position of the
ventilation flap or activate continuous movement of the
ventilation flap. This enables an even distribution of the air
current in the room.
The swing function can be switched on and off regardless of the
operating modes. The setting is maintained even if the operating
mode is changed.

1. Press the 

SWING

 button (32).

ð

The ventilation flap moves up and down continuously.

2. Press the 

SWING

 button (32) again to stop the ventilation

flap in a certain position and to switch off the swing
function.

Changing the unit °C / °F

The temperature in the 

temperature and timer

 indication (18)

can be indicated in °C or °F.
Please proceed as follows to change the temperature unit:

1. Simultaneously press the 

TIMER

 (33) and 

HUMIDITY

 (34)

buttons.

ð

The displayed temperature is converted to the other
unit.

Содержание TTK 110 HEPA

Страница 1: ...TRT BA TTK110HEPA TC 002 EN TTK 110 HEPA EN OPERATING MANUAL DEHUMIDIFIER...

Страница 2: ...r using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructi...

Страница 3: ...Ensure that the side of the device where the air inlet is found is kept free of dirt and loose objects Only transport the device in an upright position with an emptied condensation tank or drain hose...

Страница 4: ...air can be additionally improved Another feature is the device s self cleaning function This function serves to dry the interior of the device in order to prevent the formation of mould or similar in...

Страница 5: ...he following Set up the device in an upright position after transport Leave the device to rest for 12 24 hours so the refrigerant can accumulate within the compressor Wait 12 24 hours before switching...

Страница 6: ...ectric cables especially when positioning the device in the middle of the room Use cable bridges Make sure that extension cables are completely unrolled When positioning the device keep a sufficient d...

Страница 7: ...rent room temperature Indicates the number of hours of the activated timer ON is displayed if the timer for automatic switch on is active OFF is displayed if the timer for automatic switch off is acti...

Страница 8: ...d The fan speed cannot be changed The compressor switches off automatically once the desired relative room humidity has been reached The fan keeps running 1 Press the MODE button 23 until the indicati...

Страница 9: ...button 23 until the indication for the ventilation indication 19 appears on the display 2 Press the HUMIDITY button 34 to select low or high fan speed Night mode Night mode can be switched on in all o...

Страница 10: ...setting The characters OFF and the number of hours left until switch off appear on the temperature and timer indication 18 The timer setting equals the desired number of hours The device switches off...

Страница 11: ...ses when released 37 36 5 With the other hand push one end of the hose onto the hose connection 37 37 6 Let go of the fastener 36 7 Refit the condensation tank into the device Make sure not to damage...

Страница 12: ...production If malfunctions occur nonetheless check the device according to the following list The device does not start Check the power connection Check the power cable and mains plug for damages Che...

Страница 13: ...mode If the device is in air purification mode and the HEPA filter is not inserted the fan will not start Insert the HEPA filter in air purification mode see Replacing the HEPA filter The device gets...

Страница 14: ...drain hose X Check the air inlets and outlets for dirt and foreign objects and clean if necessary X X Clean the exterior X X Visually check the inside of the device for dirt X X Check the air filter f...

Страница 15: ...irt Check the air filter for dirt and foreign objects and clean or replace if necessary Replace the air filter Check the HEPA filter for dirt and foreign objects and clean or replace if necessary Repl...

Страница 16: ...de of the device cleaned by a specialist company for cooling and air conditioning or by Trotec 5 Put the air filter back in Refrigerant circuit The entire refrigerant circuit is a maintenance free her...

Страница 17: ...that it is undamaged and dry The air filter has to be cleaned as soon as it is dirty This is brought to light e g by a reduced capacity see chapter Errors and faults 1 Remove the air filter from the...

Страница 18: ...ondensation tank In doing so make sure that the float is positioned correctly In doing so make sure that the condensation tank is inserted correctly for otherwise the device cannot be switched back on...

Страница 19: ...Sensor BN BU YE GN GN YE GN GN RD Capacitor BU BU BN RD BK RD BK WH BU BU BN WH BK ELECTRIC CIRCUIT DIAGRAM YDH CN1 CN9 PH CN4 CN5 PG Water RT1 RD WH BU Photodiode Photodiode Disposal The icon with t...

Страница 20: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: