background image

EN

Operating Manual – Radial Fan TFV 900

1

Symbols

Hazardous electric current!

Warns about hazards from electric current which can
lead to injuries or even death.

Danger!

Warns of a hazard which can result in moderate to
severe injuries.

Caution!

Warns of a hazard which can result in minor injuries or
property damage.

Wear hearing protection!

Indicates the activities during which hearing protection
is to be worn.

Legal notice

This release replaces all previous versions. No part of this
publication may be reproduced without written permission from
Trotec. The same applies for electronically processing,
duplicating or spreading the publication. Subject to technical
changes. All rights reserved. Trademarks are used without
guarantee that they may be used freely and primarily following
the spelling of the manufacturer. Product names are registered.
Changes to construction in the interests of constant
improvements to the product, as well as changes to the shape
and colour are reserved.
The scope of delivery may vary from product images. This
document was created with all due care. Trotec accepts no
liability whatsoever for possible mistakes or omissions.
© Trotec

Warranty and liability

Damages caused by incorrect use by untrained people or start-up
by unauthorised people are excluded from the warranty. 
The device complies with the fundamental health and safety
requirements of the applicable EU regulations and was tested at
the factory for perfect functionality multiple times. However, if
faults in the functionality occur and cannot be remedied with the
measures in the chapter Errors and faults, please get in touch
with your dealer or distributor. When invoking the guarantee, the
data given on the fan info sheet supplied with the device is to be
quoted. When manufacturer's instructions or legal regulations
have not been followed, or after unauthorised changes to the
device are made, the manufacturer is not responsible for the
resulting damages. Changes to the device or unauthorised
replacement of individual parts can drastically impact the
electrical safety of this product and leads to the forfeit of the
warranty. Liability does not extend to damages to people or
property caused by the device being used other than as described
in the instructions in this operating manual. Subject to changes to
technical design and model changes as part of constant
development and product improvement without prior notice.
No liability is accepted for damages resulting from improper use.
In such cases, entitlements to a warranty are then also forfeited.

Table of contents

Notes regarding the operating manual .................................... 1
Safety ..................................................................................... 2
Information about the device................................................... 3
Transport and storage............................................................. 4
Start-up 
.................................................................................. 4
Operation................................................................................ 5
Errors and faults ..................................................................... 6
Maintenance 
........................................................................... 6
Technical annex...................................................................... 7

Notes regarding the operating manual

TFV 900

The current version of the operating manual can be 
found at:

http://download.trotec.com/?sku=1510002050&id=1

Содержание TFV 900

Страница 1: ...TFV 900 OPERATING MANUAL RADIAL FAN EN TRT BA TFV900 TC 001 EN ...

Страница 2: ......

Страница 3: ...h and safety requirements of the applicable EU regulations and was tested at the factory for perfect functionality multiple times However if faults in the functionality occur and cannot be remedied with the measures in the chapter Errors and faults please get in touch with your dealer or distributor When invoking the guarantee the data given on the fan info sheet supplied with the device is to be ...

Страница 4: ...TFV 900 is not suited for installation in fluids or on flooded or boggy grounds The device must not be used for transporting media other than atmospheric air e g fluids or other gases Any unauthorised changes modifications or alterations to the device are forbidden Personnel qualifications People who use this device must be aware of the dangers that occur when working with high pressure fans have ...

Страница 5: ...elivered without a frame for stationary application Optionally the device is also available with a frame as depicted for variable areas of use As for a further option the device is also available as ex proof version for the use in potentially explosive surroundings only these devices may be operated in an explosive environment The radial fan is integrated in a powder coated steel housing with high...

Страница 6: ... proximity Only instructed persons are allowed to perform the transport by use of lifting gear Consider the centre of gravity when transporting the load Storage Store the cleaned device in a dry location and protect it against dust Before restarting the device check the power cable for perfect condition Installation of the device Position the device on firm dry and level ground Depending on the pe...

Страница 7: ...o delta Hence it supplies its maximum conveying capacity for continuous operation Switch off 1 Press the red Control off button 12 The Operation lamp 10 goes out The fan resumes in rundown operation for a few seconds and then comes to a halt From this operating condition you can switch the device back on at any time Shutdown 1 Switch the device off as previously described 2 Upon standstill of the ...

Страница 8: ...main switch Before any work detach the mains plug Repair work may only be performed by qualified electricians or Trotec Cleaning the fan You may use compressed air for a thorough cleaning of the fan Do not use a high pressure cleaner for the fan Always pay attention to unusual sounds if in doubt consult the manufacturer Errors and faults Fault Cause Possible solution The motor does not start or au...

Страница 9: ...medium temperature 80 C Nominal voltage 3 N PE 400 V 50 Hz Rotary field clockwise rotating field Nominal current 32 A Recommended fusing 32 A gL Nominal capacity 18 5 kW Surrounding conditions permissible temperature range type of protection 20 C to 40 C IP 55 Mains plug CEE 32 A Engine start up star delta changeover Noise level at a distance of 1 m 82 dB A Weight without frame option with frame 4...

Страница 10: ...ed TFV 900 7141000626 4 see separate list 9 15 to 13 12 SP button red TFV 900 7130000092 5 SP air exhaust connection d 630mm 7230000002 13 SP button green TFV 900 7130000093 5b SP air exhaust connection d 600mm 7230000005 14 SP contactor control TFV 900 7140000122 7 SP castor TFV900 7600000245 16 SP changeover switch star delta K1 TFV 900 7140000120 8 SP air intake connection TFV 900 d 630mm 72300...

Страница 11: ...aintenance etc or unauthorized changes of the factory supplied device version this declaration loses its legal validity Device version radial fan Models TFV 900 Year of manufacture as of 2009 Applicable regulations 2006 42 EC 2006 95 EC 2004 108 EC Machinery Directive Low Voltage Directive EMC Directive Applied harmonised standards EN 12100 1 2 2007 EN 13857 2008 EN 60204 1 2006 EN 60034 1 2007 EN...

Страница 12: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Отзывы: