EN
9
convector TCH 2310 E / 2311 E
Setting the timer
The timer has the following functionality:
•
automatic switch-off upon expiry of a preset number of
hours.
The number of hours to be set can be between 1 and 24 and is
adjustable in increments of 1 hour. If the timer is activated, the
time is also displayed in minutes.
Note
Do not leave the operating device unattended in a
freely accessible room with an activated timer.
Automatic switch-off
ü
The device is switched on.
1. Press the
Timer
button (
17
).
2. Select the
Timer
button (
17
) to select the desired number
of hours. The value range is between 1 and 24.
ð
The number of hours flashes on the
Timer
indication (
18
).
ð
The desired time until automatic switch-off is saved as
soon as the
Timer
(
18
) indication stops flashing.
ð
The time left until switch-off is displayed in the
Timer
indication (
18
) and counted down.
ð
The device will switch to standby mode.
Note regarding automatic switch-off:
•
Manually switching the device off disables the automatic
switch-off function.
•
If you select 0 hours, the timer will be switched off.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
1. Switch the device off by setting the mains switch to
position
0
.
2. Hold onto the mains plug while pulling the power cable out
of the mains socket.
3. Allow the device to cool down sufficiently.
4. Clean the device according to the Maintenance chapter.
5. Store the device according to the Storage chapter.
Errors and faults
Warning of electrical voltage
Tasks which require the housing to be opened
must only be carried out by authorised specialist
companies or by Trotec.
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
•
Check the power connection.
•
Check the power cable and mains plug for damages.
•
Check the on-site fusing.
•
The room thermostat might be defective. Have a defective
room thermostat replaced by a specialist electrical
company.
•
Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.
The device is switched on, but the heating is not operating:
•
The heating resistor might have blown. Have a defective
heating resistor replaced by a specialist electrical
company.
•
The room thermostat might be defective. Have a defective
room thermostat replaced by a specialist electrical
company.
•
The room thermostat might be defective. Have a defective
room thermostat replaced by a specialist electrical
company.
The air current is reduced:
•
Check the air inlet and outlet. Make sure that air inlet and
outlet are not obstructed. Remove any dirt. Observe the
minimum distance from walls or other objects according to
the technical data.
The device does not respond to the infrared remote control:
•
Check whether the distance between remote control and
device is too large and reduce it if necessary.
•
Make sure there are no obstacles, such as furniture or
walls, between the device and the remote control. Ensure
visual contact between device and remote control.
•
Check the charging status of the batteries and change
them if required.
•
If the batteries have just been changed, check them for
correct polarity.
Note
Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to an authorised specialist electrical company or to
Trotec for repair.