background image

8

EN

convector TCH 2310 E / 2311 E

Remote control

All settings of the device can also be made using the remote
control included in the scope of delivery.

15

12

10

24

13

16

17

14

No.

Designation

Meaning

12

°C/°F

 button

Changing between °F/
Fahrenheit and °C/Celsius

13

Mode

 button

Selecting the operating mode:
Heating mode
Frost monitor mode

15

Increase value

 button

Set the desired room
temperature (5° C to 37 °C)

16

Decrease value

 button

17

Timer

 button

Switching the timer on and off,
setting the number of hours of
the timer (1 to 24 h)

10

Power

 button

For switching the device on or
activating standby mode

14

Ventilation

 button

Switching the fan on or off

24

Infrared transmitter
remote control

Sends signals to the device

Info

The indication comes with a background illumination.
The background illumination switches on as soon as
one of the control panel buttons or the remote control
is pressed. After approx. 1 min without any actuation,
the background illumination switches back off.

Switching the device on

Once you have completely installed the device as described in
the Start-up chapter, you can switch it on.

1. Set the on/off switch (

1

) to position 

I

.

ð

The device is now in standby mode.

2. Press the 

Power

 button (

10

).

ð

The device is switched on.

Setting the operating mode

The device has the following operating modes:

Heating mode

Frost monitor mode

Adjusting the heating mode

1. Press the 

Mode 

 button (

13

) until the desired heating level

is selected. You can choose from three different levels.

ð

The selected performance level (

20

) is indicated on the

segment display.

Frost monitor mode

In frost monitor mode the device heats automatically. This
temperature cannot be changed.

1. Press the 

Mode

 button (

13

) until the 

Frost monitor

indication (

21

) is displayed.

ð

The device heats automatically if the temperature falls
below 5 °C.

For setting the desired room temperature

The room temperature determined by the temperature sensor is
displayed on the 

Current temperature

 indication (

19

). You can

set the desired room temperature at any time.
Setting the room temperature is only possible in heating mode.
The room temperature is preset to 25 °C.

1. Press the arrow button 

increase value

 (

15

) or 

decrease

value

 (

16

) to adjust the desired room temperature. Setting

is possible in the range between 5 °C and 37 °C in
increments of 1 °C.

ð

The set room temperature is displayed in the 

Target

temperature

 indication (

23

).

Info

The desired room temperature should be higher than
the current room temperature.

Ventilation

1. Press the 

Ventilation

 button (

14

) to switch on the fan.

ð

The 

Ventilation

 indication (

22

) appears.

2. Press the 

Ventilation

 button (

14

) to switch off the fan.

ð

The 

Ventilation

 indication (

22

) disappears.

Содержание TCH 2310 E

Страница 1: ...TRT BA TCH2310E 2311E TC2020 44 001 EN TCH 2310 E 2311 E EN OPERATING MANUAL CONVECTOR EN This product is only suitable for well insulated spaces or occasional use ...

Страница 2: ...store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory o...

Страница 3: ...rsons in order to avoid a hazard Defective power cables pose a serious health risk During the installation of the device observe the minimum distances from walls and other objects as well as the storage and operating conditions specified in the Technical data chapter Do not use the device in immediate proximity to curtains beds or sofas Make sure that the air inlet and outlet are not obstructed Ma...

Страница 4: ...ehaviour in the event of an emergency 1 Switch off the device 2 In an emergency disconnect the device from the mains feed in Hold onto the mains plug while pulling the power cable out of the mains socket 3 Do not reconnect a defective device to the mains Overheating protection The device is provided with a safety thermostat which is activated by overheating of the device when exceeding the operati...

Страница 5: ...the device off Hold onto the mains plug while pulling the power cable out of the mains socket Do not use the power cable to drag the device Allow the device to cool down sufficiently Storage Before storing the device proceed as follows Switch off the device Hold onto the mains plug while pulling the power cable out of the mains socket Allow the device to cool down sufficiently When the device is n...

Страница 6: ...alls or other objects as described in the chapter Technical data A B C C D Before restarting the device check the condition of the power cable If there are doubts as to the sound condition contact the customer service Set the device up in an upright and stable position Do not create tripping hazards when laying the power cable or other electric cables especially when positioning the device in the ...

Страница 7: ...e button Set the desired room temperature 5 C to 37 C 16 Decrease value button 17 Timer button Switching the timer on and off setting the number of hours of the timer 1 to 24 h Segment display 19 20 21 22 23 18 No Designation Meaning 18 Timer indication Indication of the remaining hours and minutes of the activated timer 19 Current temperature indication Indication of the current room temperature ...

Страница 8: ...d on Setting the operating mode The device has the following operating modes Heating mode Frost monitor mode Adjusting the heating mode 1 Press the Mode button 13 until the desired heating level is selected You can choose from three different levels ð The selected performance level 20 is indicated on the segment display Frost monitor mode In frost monitor mode the device heats automatically This t...

Страница 9: ... during production If malfunctions occur nonetheless check the device according to the following list The device does not start Check the power connection Check the power cable and mains plug for damages Check the on site fusing The room thermostat might be defective Have a defective room thermostat replaced by a specialist electrical company Wait for 10 minutes before restarting the device If the...

Страница 10: ...electrical voltage Tasks which require the housing to be opened must only be carried out by authorised specialist companies or by Trotec Cleaning the housing Warning of electrical voltage Never immerse the device in water Clean the housing with a soft damp and lint free cloth Ensure that no moisture enters the housing Protect electrical components from moisture Do not use any aggressive cleaning a...

Страница 11: ... to 37 C Mains connection 220 240 V 50 60 Hz 220 240 V 50 60 Hz Power consumption 2300 W 2300 W Nominal current consumption 10 A 10 A Cable length 1 8 m 1 8 m Plug type CEE 7 7 CEE 7 7 Dimensions incl feed excl wheels depth x width x height 215 x 690 x 435 mm 215 x 690 x 435 mm Minimum distance to walls and other objects A top B rear C side D front 100 cm 100 cm 100 cm 100 cm 100 cm 100 cm 100 cm ...

Страница 12: ...room and or outdoor temperature feedback NO NO Fan assisted heat output NO NO Type of heat output room temperature control Single stage heat output no room temperature control NO NO Two or more manual stages no room temperature control NO NO With mechanic thermostat room temperature control NO NO With electronic room temperature control NO NO With electronic room temperature control plus day timer...

Страница 13: ...ttps de trotec com shop The separate collection of waste electrical and electronic equipment aims to enable the re use recycling and other forms of recovery of waste equipment as well as to prevent negative effects for the environment and human health caused by the disposal of hazardous substances potentially contained in the equipment In the European Union batteries and accumulators must not be t...

Страница 14: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Отзывы: