EN
8
Operating manual – designer glass convector TCH 2010 E / TCH 2011 E
Setting the operating mode
Mode
The following types of heating can be selected:
•
Comfort heating mode
(heating capacity 2000 W)
•
Economy heating mode
(heating capacity 1000 W)
•
Frost monitor heating mode
1. Press the
MODE
button (17) until the desired heating mode
is selected.
ð
The selected mode and the
heating
indication (11) will
be displayed edged in black.
Comfort heating mode
The device operates with a heating capacity of 2000 W until
reaching the desired room temperature. Upon reaching the
desired room temperature the device reduces its heating
capacity to 1000 W. The
comfort heating mode
indication (8)
continues to be displayed.
If the determined room temperature exceeds the desired room
temperature by 2 °C, the heating switches off.
The
heating
indication (11) is no longer framed.
If the determined room temperature falls below the desired
room temperature by 2 °C, the heating switches back to
comfort heating mode
.
Economy heating mode
The device operates with a heating capacity of 1000 W until the
determined room temperature reaches the desired room
temperature. Then the heating switches off.
The
heating
indication (11) is no longer framed.
If the determined room temperature falls below the desired
room temperature by 2 °C, the heating switches back to
economy heating mode
.
Frost monitor heating mode
In
frost monitor heating mode
the devices heats automatically if
the room temperature is below 5 °C. This temperature cannot
be changed.
Setting the desired room temperature
The room temperature determined by the temperature
sensor (5) is displayed on the
temperature
indication (21). You
can set the desired room temperature at any time.
The room temperature is preset to 35 °C.
1. Press the
TEMP
button (13).
ð
The
temperature
indication (21) flashes.
ð
The desired room temperature is displayed.
2. Press the arrow buttons
increase value
(16) or
decrease
value
(15) to adjust the desired room temperature. Setting
is possible in the range between 15 °C and 35 °C in
increments of 1 °C.
ð
The desired room temperature is saved and shown on
the
temperature
indication (21) for approx. 5 seconds.
Then the current room temperature is displayed again.
Info
The desired room temperature should be higher than
the current room temperature.
Setting the timer
The timer has the following functionality:
•
automatic switch-off upon expiry of a preset number of
hours.
The timer run-time can be between 1 minute and 24 hours and
can be adjusted in increments of 1 min.
Notice
Do not leave the operating device unattended in a
freely accessible room with an activated timer.
Automatic switch-off
ü
The device is switched on.
1. Press the
TIME
button (14).
2. Select the desired number of hours by use of the arrow
buttons (15 or 16). The value range is between 1 and 23.
ð
The number of hours flashes on the
hours / minutes
indication (19).
3. Press the
TIME
button (14).
4. Select the desired number of minutes by use of the arrow
buttons (15 or 16). The value range is between 1 and 59.
ð
The number of minutes flashes on the
hours / minutes
indication (20).
5. Press the
TIME
button (14).
ð
The desired time until automatic switch-off is saved.
ð
The
timer
indication (19) flashes.
ð
The time left until switch-off is shown on the
hours /
minutes
indication (20) and counted down.
ð
In device will then switch to standby mode.
Notes regarding automatic switch-off:
•
Manually switching the device off disables the automatic
switch-off function.
•
If you select 0 hours / minutes, the timer will be off.