background image

5

EN

Operating manual – designer glass convector TCH 2010 E / TCH 2011 E

Assembly

Assembly of feet with castors

1. Place the device on a table or on the packaging board with

the glass surface pointing down.

2. Fasten both feet (3) with 3 screws each.

3

3. Check the feet (3) for tight fit.
4. Set the device up in an upright and stable position.
5. If required, engage the parking brakes (7) by pushing the

lever down.

MODE

TIME

TEMP

TCH2010 E

7

Wall mounting

Instead of being positioned on the feet, the device may also be
mounted to a wall.

100 cm

5 cm

50 cm

50 cm

Do not install the device directly behind a door.

Do not install the device directly below a wall socket.

Never install the device in a way that it radiates directly
onto walls or other objects.

Only install the device in a horizontal position.

1. Mark the positions for the bore holes on the wall. Observe

the minimum distances.

515 mm

265 mm

280 mm

2. Drill the holes into the wall at the marked positions.

Содержание TCH 2010 E

Страница 1: ...TRT BA TCH2010E TCH2011E TC 003 EN TCH 2010 E TCH 2011 E EN OPERATING MANUAL DESIGNER GLASS CONVECTOR EN This product is only designed for use inside well insulated rooms or for occasional use ...

Страница 2: ...ity via the following link TCH 2010 E https hub trotec com id 41233 TCH 2011 E https hub trotec com id 41234 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire an...

Страница 3: ...ent or similarly qualified persons in order to avoid a hazard Defective power cables pose a serious health risk During the installation of the device observe the minimum distances from walls and other objects as well as the storage and operating conditions specified in the Technical data chapter Do not use the device in immediate proximity to curtains Ensure that the air inlet and outlet are not o...

Страница 4: ...plug while pulling the power cable out of the mains socket 3 Do not reconnect a defective device to the mains Overheating protection The device is provided with a safety thermostat which is activated by overheating of the device when exceeding the operating temperature Once the safety thermostat has switched itself on the device will be turned off When the device has cooled down sufficiently the h...

Страница 5: ...he device Allow the device to cool down sufficiently Storage Before storing the device observe the following Allow the device to cool down sufficiently When the device is not being used observe the following storage conditions dry and protected from frost and heat in an upright position where it is protected from dust and direct sunlight with a cover to protect it from invasive dust if necessary P...

Страница 6: ... by pushing the lever down MODE TIME TEMP TCH2010 E 7 Wall mounting Instead of being positioned on the feet the device may also be mounted to a wall 100 cm 5 cm 50 cm 50 cm Do not install the device directly behind a door Do not install the device directly below a wall socket Never install the device in a way that it radiates directly onto walls or other objects Only install the device in a horizo...

Страница 7: ...tarting the device check the condition of the power cable If there are doubts as to the sound condition contact the customer service Set the device up in an upright and stable position or suspend the device horizontally Do not create tripping hazards when laying the power cable or other electric cables especially when positioning the device in the middle of the room Use cable bridges Make sure tha...

Страница 8: ... value button 17 MODE button Selecting the operating mode Comfort heating mode Economy heating mode Frost monitor heating mode 18 Power button Switching the device on or activating standby mode 19 Timer indication Flashes when the timer is activated 20 Hours minutes indication Indication of the number of hours and minutes during timer programming Indication of remaining timer run time 21 Temperatu...

Страница 9: ...tion 21 You can set the desired room temperature at any time The room temperature is preset to 35 C 1 Press the TEMP button 13 ð The temperature indication 21 flashes ð The desired room temperature is displayed 2 Press the arrow buttons increase value 16 or decrease value 15 to adjust the desired room temperature Setting is possible in the range between 15 C and 35 C in increments of 1 C ð The des...

Страница 10: ...ccording to the Storage chapter Errors and faults Warning of electrical voltage Tasks which require the housing to be opened must only be carried out by authorised specialist companies or by Trotec The device has been checked for proper functioning several times during production If malfunctions occur nonetheless check the device according to the following list The device does not start Check the ...

Страница 11: ...Hold onto the mains plug while pulling the power cable out of the mains socket Allow the device to cool down completely Warning of electrical voltage Tasks which require the housing to be opened must only be carried out by authorised specialist companies or by Trotec Cleaning the housing Warning of electrical voltage Never immerse the device in water Clean the housing with a soft damp and lint fre...

Страница 12: ... control with room and or outdoor temperature feedback NA NA Fan assisted heat output NA NA Type of heat output room temperature control Single stage heat output no room temperature control NO NO Two or more manual stages no room temperature control NO NO With mechanic thermostat room temperature control NO NO With electronic room temperature control NO NO With electronic room temperature control ...

Страница 13: ...refer to our website www trotec24 com The separate collection of waste electrical and electronic equipment aims to enable the re use recycling and other forms of recovery of waste equipment as well as to prevent negative effects for the environment and human health caused by the disposal of hazardous substances potentially contained in the equipment In the European Union batteries and accumulators...

Страница 14: ......

Страница 15: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...