NORMAL.DOT
Gespeichert in:G:\Support\Dokumentationen_CDs\8003Speedy\Service Manual\Servicemanual 8003.doc
Gespeichert am:2003/03/10
max
Version 14
Seite 26 von 87
I N D I V I D U A L M A R K I N G S Y S T E M S
4. Take out the metal grid and disconnect the cooling fans.
Pull out the black-red power cable.
5. Remove the fan enclosure
6. Pull out the power cable (black-red) and unplug the signal cable on the lasertube.
7.
CAUTION:
Before you perform that step please ask a second person to assist
you. The risk here is to drop the tube. Loosen the two 4mm screws on the right
side of the tube and remove the four philips screws on the left side (before you
can do that remove the cover of mirror unit 1).
8. Remove the tube
9. Assemble the new tube in the reverse way.
10. After the replacement you´ve to do the beam alignment.
Laser tube replacement (50W and 100W)
1. Switch off the Speedy and open the service acces panel using a 10 mm allen
key. Remove also the cover of the electronic compartment.
2. Unplug the power connector (black-red) for the lasertube on the main board.
3. Remove the tube enclosure.
4. Disconnect the six push fit fittings that are connected to the tube and
disassemble the two that fix the plastic water distributor.
5. Remove also all fittings on the left side of the tube.
6. Pull out the power cable (black-red) and unplug the two signal cables on the
lasertube.
7.
CAUTION:
Before you perform that step please ask a second person to assist
you. The risk here is to drop the tube. Loosen the two 4mm screws on the right
cooling fan
connector
BNC
connector
metal
grid
fixing
screws of
cooling fan
protective
cover
power
cable
fan
enclosure
e