I N D I V I D U A L M A R K I N G S Y S T E M S
the upper part of the
engravings is missing
outdated firmware version
installed
after closing of the door the
job was started
immediately
update firmware
after closing the door wait
5 seconds to start the job
2. Machine malfunctions
Problem description
Possible reason
Solution
no referencing after start
up
top door not closed
defect in the interlock
system
mechanical problem on
axis
bad limit switch
defect power supply
close door
check interlocks
make sure that the
mechanical resistance is
small
replacement
measure voltage, if
necessary replace it
no response at switching
on of the system
main fuses blown
power supply defect
replace fuses
replace power supply
no communication to
engraver
invalid COM port selection
serial cable defect
change selection
replace cable
connection to engraver
breaks frequently
electromagnetic imissions
make sure that engraver
and computer are
connected to the same
electric curcuit
the original cable lenghts
should not be exceeded
offsets between engraving
jobs and cut lines
dusty encoder
top speed too high
acceleration too high
clean encoder
reduce speed
reduce acceleration
3. Noise generation
Problem description
Possible reason
Solution
noisy cooling fans
damaged ball bearings
incorrect supply voltage
old fan version
replace fan
replace fan
replace fan for NMB
version
noisy table
outdated firmware version
update firmware
sqeaking on movement in
X-direction
belt grips touch X-axis
profile
move grips