background image

14

EN

insulation drying unit Qube+

Fault messages

The following fault messages may appear on the LC display:

Fault message

Cause

Remedy

Behaelter getrennt!
(tank disconnected)

The electrical
contact between
the upper and
lower part is
disrupted. The
motor switches
off.

Check whether the
upper and lower part of
the device are firmly
connected via the
tension locks. Check
the contacts of the
upper and lower part.
Clean if necessary.

Pumpe
Abkuehlphase..
(cooling phase
pump)

The pump is in
continuous
operation mode
and has no time
to cool down.

No action required.
The cooling phase lasts
15 min. Then the
device starts up again
and resumes operation
with the previously
selected settings.

Behaelter voll!
(tank full)

The water tank is
full.

No action required.
The pump drains the
accumulated water via
the drain hose. The
motor switches off. The
motor will only switch
back on and the Qube
will only continue to
operate once the water
has been drained.

Pumpe pruefen!
(check pump)

The pump is
blocked and can
no longer operate.

Press the button for
draining residual
water (10). If the pump
is still blocked, switch
the device off. Clean
tank and pump
thoroughly.

The pump is in
operation but
there is no water
in the tank.

Switch the Qube off
and back on. If the
message appears
again, check the water
level sensor and clean
this area thoroughly.

Too much water
in the insulation
layer or an
unconnected
drain hose causes
the pump to
operate
continuously.

Check the drain hose
for proper fit. There
must be no kinks or
loops in the hose that
could prevent the water
from being drained off.
Check for potential
leakage.

Fault message

Cause

Remedy

abpumpen...
(pumping off)

The pump drains
the accumulated
water.

No action required.
If the pump is to run
permanently, the water
should be removed
with an industrial
suction unit in a first
step.

Filter wechseln!
(change filter)

The G4 or F8 filter
sleeve or the
HEPA filter is
clogged.

Exchange the filter
sleeve. In case a HEPA
filter is used and the
message continues to
be shown on the
display, the HEPA filter
itself must be
exchanged as well.

12V Netzteil
pruefen 
(check 12 V power
adapter)

The sensor for
monitoring the
water level is not
working properly.

Please contact the
customer service.

Temperatur 1!
(temperature 1)

The temperature
within the device
exceeds the
permissible value,
this tripped the
overheating
protection.

No action required.
The air flow rate will be
adjusted automatically.
Investigate the cause
of overheating if
required to prevent
further overheating.

Temperatur 2!
(temperature 2)

The temperature
within the device
exceeds the
permissible value,
this tripped the
overheating
protection. The
device has
switched off.

Investigate the cause
of overheating.
If necessary, direct the
warm air out of the
room. A room
temperature of more
than 35 °C is to be
avoided during
operation. Also observe
the information in the
Set-up chapter.

Содержание Qube+

Страница 1: ...TRT BA QUBE TC2015 27 010 EN QUBE EN ORIGINAL INSTRUCTIONS INSULATION DRYING UNIT ...

Страница 2: ...ormity via the following link Qube https hub trotec com id 40717 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Do not use the device in potentially explosive rooms Do not use the device in aggressive atmosphere Set the device up in an upright and stable position Make sure that the air inlet a...

Страница 3: ... Warning Small objects and particles can be sucked in and lead to injuries Make sure that no person is standing near the inlet or outlet opening while the device is running Warning Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way Observe the personnel qualifications Warning Risk of suffocation Do not leave the packaging lying around Children ...

Страница 4: ... for discharge of hot process air Service socket tamper proof Cable holder Key lock to prevent maloperation ECO level stage 1 for small surfaces Height adjustable telescopic push handle The device is equipped with a touch screen with LC display It provides information on the operating stage air flow rate etc The background colour of the LC display changes according to the traffic light principle t...

Страница 5: ...parking brake 10 Residual water draining button 11 Hose connectors 12 DA 4 sensor connection 13 Power button and communication port 14 Touchscreen control panel 15 Castor retainer for storage 16 Power cable retainer 17 Carrying handle upper part 18 19 21 22 20 23 No Designation 18 Connection for discharge of process air 19 Connector 50 mm 20 Service socket tamper proof 21 Holder for storage with r...

Страница 6: ... 32 33 29 35 No Designation 23 F7 air filter 24 Air filter cover 25 F8 filter sleeve for HEPA filter optional 26 HEPA filter optional 27 Pump 28 Coarse filter 29 Coarse filter fixation grid 30 Demister holder 31 Demister 32 Wing nut 33 Cage 34 G4 filter sleeve 35 Spring contacts for electrical connection ...

Страница 7: ...mponents Prior to every transport check whether the upper and lower part of the device are firmly connected via the tension locks Do not incline the device by more than 45 for otherwise the device could be damaged Storage Before storing the device proceed as follows Empty and clean the condensation tank prior to storage Hold onto the mains plug while pulling the power cable out of the mains socket...

Страница 8: ...sories Art no 38 mm connector 7 200 000 002 HEPA filter module H13 high efficiency particulate air filter as per DIN EN 1822 1 filtration efficiency 99 97 0 3 µm incl F8 prefilter sleeve DIN EN 779 7 160 000 221 F8 filter sleeve for HEPA filter module filter class 8 DIN EN 779 7 160 000 215 F8 filter sleeve 7 160 000 216 connection cable VX DA for data transmission to the DA 4 7 333 000 015 sound ...

Страница 9: ...the water discharge connection 2 Guide the other hose end to a drain or collection container Regularly inspect the drain hose and hose connection for kinks and dirt Remove kinks and clean the drain hose if required TTKwic quick couplings As standard the device comes with two integrated TTKwic quick couplings 7 where condensate discharge hoses of up to two used dehumidifiers plus condensate pump ca...

Страница 10: ...installation Remove the sealing caps from the connectors to which you want to connect a hose If a connector is not needed the sealing cap must remain on the connector Note Connectors without a sealing cap or a connected hose may cause water to escape and thus result in water damages Carefully check the connectors before switching the device on For drying operations only use cables and sockets comp...

Страница 11: ...thus reducing the noise emission e g at night Whisper mode is automatically left after 10 h and the compressor starts to run at its previously chosen power stage again Selecting another stage via the control panel will also stop the whisper mode Press the whisper mode button 40 to activate or deactivate whisper mode A countdown 10 h on the control panel indicates the remaining whisper mode duratio...

Страница 12: ...e determined Info If a load is connected to the service socket its energy consumption will also be measured by the energy meter Connecting the DA 4 external control unit The communication port 41 is used for data transfer to the DA 4 control unit The data may then be forwarded USB and modem or USB only Additionally the internal sensor of the DA 4 must be connected via the sensor connection 12 Empt...

Страница 13: ...ary Motor is not running Check the display If Behaelter getrennt is indicated the upper part may not be correctly positioned on the lower part Check whether the upper and lower part are properly connected to one another Check whether voltage is applied Check the electrical connections and safety installations Motor switches off during operation or its performance is reduced The device has been ove...

Страница 14: ...much water in the insulation layer or an unconnected drain hose causes the pump to operate continuously Check the drain hose for proper fit There must be no kinks or loops in the hose that could prevent the water from being drained off Check for potential leakage Fault message Cause Remedy abpumpen pumping off The pump drains the accumulated water No action required If the pump is to run permanent...

Страница 15: ...rocess https www youtube com watch v 8_G8kCDMHIM Cleaning the housing Clean the device with a soft damp and lint free cloth Ensure that no moisture enters the housing Protect electrical components from moisture Do not use any aggressive cleaning agents such as cleaning sprays solvents alcohol based or abrasive cleaners to dampen the cloth Draining residual water The residual water should always be...

Страница 16: ...s it does not allow a sufficient quantity of air to pass Observe the following before cleaning or replacing the filter Press the power button 42 to switch the device off Disconnect the device from the mains Drain the residual water from the tank The device is equipped with different filter types G4 filter sleeve 34 F8 filter sleeve also an option here F8 filter sleeve for HEPA filter optional 25 H...

Страница 17: ...eplacing the G4 filter sleeve If the Filter wechseln message appears on the display the G4 filter sleeve inside the device must be replaced as it does not allow a sufficient quantity of air to pass ü The device is switched off and disconnected from the mains ü The residual water has been drained 1 Open the 4 tension locks 4 2 Lift the upper part at the carrying handle 17 and place it onto a stable...

Страница 18: ... locks Cleaning the demister ü The device is switched off and disconnected from the mains ü The residual water has been drained ü The upper part has been removed see Replacing the G4 filter sleeve 1 Take the demister out of the holder in the lower part of the device 2 Rinse the demister under running water ð Exchange the demister if required e g in case of damages 3 Put the demister back into the ...

Страница 19: ...uick coupling of the hose 43 on the tank wall 5 Slightly lift the sheet that is fixating the pump 6 Take out the pump 7 Detach the pump filter from the pump 8 Rinse the pump filter under running water ð Exchange the pump filter if required e g in case of damages 9 Slightly lift the sheet that is fixating the pump and refit the pump 10 Check the pump for tight fit 11 Plug the hose 43 back into the ...

Страница 20: ...al connection and put the plug 44 back in 11 Refit the coarse filter fixation The coarse filter fixation should rest on the coarse filter 12 Refit the demister along with the holder 13 Put the upper part back on the device and close the tension locks Replacing the G4 filter sleeve by an F8 filter sleeve optional If a finer ambient air filtration is required the G4 filter sleeve can be replaced by ...

Страница 21: ... display during operation you can exchange the F8 filter sleeve in a first step If this is not sufficient Filter wechseln message still displayed the HEPA filter must be exchanged as well ü The device is switched off and disconnected from the mains ü The residual water has been drained 1 Please proceed as described in steps 1 and 2 in the chapter Replacing the G4 filter sleeve 2 Turn the upper par...

Страница 22: ...dB A Volume collection container 10 l Input voltage 230 V 50 Hz Weight 27 kg Dimensions L x W x H telescopic push handle down up 490 x 500 x 735 925 mm Mobility carrying handle stackable rollable carriage design Hose connections insulation drying 3 x ø 38 mm TTKwic dehumidifier quick couplings 2 x Waste water connection DA 4 interface Efidry humidity sensor connection Service socket tamper proof 5...

Страница 23: ...via Optiflow NT multi function display 3 What does MID compliant mean In some areas the Measuring Instruments Directive MID replaces the previous regulation of national authorization and subsequent calibration As a result all energy meters in Europe used for energy consumption based billing have to be MID compliant from now on Therefore the Qube holds a separate certified MID compliant counter whi...

Страница 24: ...ying unit Qube Exploded assembly drawing Info The position numbers of the spare parts differ from those describing the positions of the components mentioned in these instructions A B 2 3 4 1 11 12 7 13 6 8 9 10 5 14 15 16 ...

Страница 25: ...m 6 P10003459 housing Qube filter insert 7 7 160 000 221 HEPA filter module H13 incl F8 prefilter sleeve 8 P10000203 demister insert 9 P10002223 housing Qube demister holder 10 P10006736 Qube water separator bottom filter mat 11 7 160 000 213 F7 Z line filter 12 P10003460 housing Qube cover air aperture 13 7 160 000 214 G4 filter sleeve 14 7 331 000 476 drain hose 5 m 15 7 170 001 201 pump with pl...

Страница 26: ...contents of the declaration of conformity The signed declaration of conformity can be found at https hub trotec com id 40717 Declaration of conformity In accordance with the EC Machinery Directive 2006 42 EC Annex II part 1 Section A Herewith we Trotec GmbH Co KG declare that the machinery designated below was developed constructed and produced in compliance with the requirements of the EC Machine...

Страница 27: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Отзывы: