EN
13
spot cooling air conditioning unit PT 2000 SP
Cleaning the air filter
The air filter has to be cleaned as soon as it is dirty. This is
brought to light e.g. by a reduced capacity (see chapter Errors
and faults).
Warning
Ensure that the air filter is not worn or damaged. The
corners and edges of the air filter must not be
deformed or rounded. Before reinserting the air filter,
make sure that it is undamaged and dry!
1. Remove the air filter from the device.
7
2. Clean the filter using a slightly damp, soft, lint-free cloth. If
the filter is heavily contaminated, clean it with warm water
mixed with a neutral cleaning agent.
3. Allow the filter to dry completely. Do not insert a wet filter
into the device!
4. Reinsert the air filter into the device.
7
Condensate discharge (manual draining)
In
cooling
mode condensate is formed, which is mostly
discharged via the exhaust air.
The remaining condensate is collected in a container within the
housing. The condensate ought to be drained regularly.
If too much condensate accumulates, the device switches off
and indicates this via the
Condensation tank full
LED (
8
). In
addition, n acoustic signal is emitted.
ü
The device is switched off.
1. Pull the condensation tank (
6
) out of the designated
recess.
8
6
2. Empty the condensation tank.
3. Refit the emptied condensation tank into the device.
ð
The
condensation tank full
LED (
8
) goes out once you
restart the device.
Activities required after maintenance
If you want to continue using the device:
•
Reconnect the device to the mains.
If you do not intend to use the device for a considerable time:
•
Store the device according to the Transport and storage
chapter.