Operating manual – local air conditioner PAC 2000 S / PAC 2600 S
Remote control
All settings of the device can also be made using the remote
control included in the scope of delivery.
23
13
21
16
22
14
19
No. Designation
Meaning
13 Fan stage
button
Setting the fan stage:
stage 1 = low fan speed
stage 2 = high fan speed
14
Plus
button
Increasing the target temperature (15 °C
to 31 °C) for cooling
Increasing the number of hours for the
timer (1 h to 24 h)
16 Timer button
Switching the timer function on and off
19 Power button
Switching the device on and off
21 Night mode
button
Switching night mode on and off
22
Minus
button
Reducing the target temperature (15 °C
to 31 °C) for cooling
Reducing the number of hours for the
timer (1 h to 24 h)
23 Operating
mode button
Selecting the operating mode:
ventilation
dehumidification
cooling
automatic operation
Automatic defrost
At low ambient temperatures, ice may form at the evaporator.
The device will then carry out an automatic defrost.
The compressor switches off and the fan keeps running until
defrosting is completed. The duration of the defrost process can
vary.
Do not switch the device off during automatic defrost. Do not
remove the mains plug from the mains socket.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Switch off the device.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
•
Empty the condensation tray if necessary.
•
If necessary, remove the condensation drain hose and any
residual fluid from it.
•
Clean the device according to the Maintenance chapter.
•
Store the device according to the Storage chapter.