Operating manual – local air conditioner PAC 2000 S / PAC 2600 S
Setting the operating mode
Ventilation
Info
Remove the exhaust air hose during
ventilation
.
In
ventilation
mode the room air is circulated, it will neither be
cooled nor dehumidified. The temperature cannot be adjusted.
1. Press the operating mode button (23) until the ventilation
LED (24) is illuminated.
2. Press the fan stage button (13) to set the desired fan
stage.
ð
The fan stage LED (12) for the desired fan stage will be
illuminated.
ð
The ventilation LED (24) will be illuminated to indicate
ventilation
mode.
ð
The current room temperature is indicated on the
segment display (15).
Dehumidification
Info
Remove the exhaust air hose during
dehumidification
,
otherwise the performance will be insufficient.
In
dehumidification
mode the humidity level in the room is
reduced.
The temperature cannot be adjusted and the fan runs at speed
level 1.
1. Press the operating mode button (23) until the
dehumidification LED (24) is illuminated.
ð
The fan stage LED (12) for fan stage 1 will be
illuminated.
ð
The dehumidification LED (24) will be illuminated to
indicate
dehumidification
mode.
ð
The current room temperature is indicated on the
segment display (15).
Info
If the device is operated in a very humid environment,
the accumulating condensate must be discharged at
regular intervals (see chapter Condensate discharge).
Cooling
In
cooling
mode the room will be cooled down to the desired
target temperature.
1. Press the operating mode button (23) until the cooling
LED (24) is illuminated.
ð
The current room temperature is indicated on the
segment display (15).
2. Repeatedly press the plus (14) or minus (22) button to
select the desired target temperature. The temperature
can be adjusted in increments of 1 °C in a range between
15 °C and 31 °C.
ð
The desired target temperature flashes on the segment
display (15) for approx. 5 s. Then the segment
display (15) changes back to the current room
temperature.
3. Press the fan stage button (13) to set the desired fan
stage.
ð
The fan stage LED (12) for the desired fan stage will be
illuminated.
ð
The cooling LED (24) will be illuminated to indicate
cooling
mode.
Info
If the device is operated in a very humid environment,
the accumulating condensate must be discharged at
regular intervals (see chapter Condensate discharge).
Automatic operation
In
automatic operation
mode the cooling process will be
regulated depending on the ambient temperature and the preset
target temperature of 24 °C.
•
With an ambient temperature equal to or above 24 °C the
device automatically runs in
cooling
mode until the target
temperature of 24 °C is reached.
•
At an ambient temperature between 22 °C and 24 °C, the
device will automatically be operated in
ventilation
mode.
•
The target temperature is preset to a fixed value of 24 °C
and cannot be changed manually.
1. Press the
operating mode
button (23) until the automatic
operation LED (24) is illuminated.
ð
The current room temperature is indicated on the
segment display (15).
2. Press the fan stage button (13) to set the desired fan
stage.
ð
The fan stage LED (12) for the desired fan stage will be
illuminated.
ð
The automatic operation LED (24) will be illuminated to
indicate
automatic operation
.