background image

Operating manual – IDS 100

B-6

EN

13. Transport

 Switch the device off as described in the chapter "Functions and
operation".

 Wait until the device has cooled down completely.

 Before transporting or adjusting the device, check if the tank cap
is tightly closed.

Risk of environmental pollution! 

Heating oil may leak during transport or handling of the 
device. The filling plug of the tank cap does not guaran-
tee tightness in order to allow air to be introduced and 
the tank to be emptied during operation.
Only transport or shift the device with the tank cap tightly 
closed.

14. Care and maintenance

In order to ensure a trouble-free operation of the device, the combustion 
chamber, the burner and the fan are to be cleaned regularly.

 Switch the device off as described in the chapter "Functions and
operation".

 Wait until the device has cooled down completely.

Cleaning after every 50 operating hours

 Dismount the heating oil filter. Remove the filter insert and clean
it using clean heating oil.

 Dismount the upper housing part and clean the inner part as well
as the fan blades using a cleaning fleece and a brass brush if it
is heavily soiled.

 Check the condition of all cables and high-voltage connections.

 Dismount  the  burner  and  clean  its  components  using  a  brass
brush.

 Clean the electrodes. Check the distance of the electrodes and
adjust it if required (see figure).

3 mm

 Have the combustion chamber cleaned by the customer service.

 Mount the components in the reverse order.

Cleaning the oil heating unit

 Wipe  the  exterior  of  the  device  using  a  wet  cloth. The  painted
and plastic surfaces may not be scoured. Do not use any solvent-
based cleaning agents.

15. Disposal

The heating oil must be drained from the tank of the oil heating unit and 
collected.

Oil heating unit

Electronic equipment may not be disposed of in the domestic waste, but 
must be correctly disposed of in accordance with the EUROPEAN PARLIA-
MENT directive 2002/96/EC of 27th January 2003 regarding used electri-
cal and electronic equipment. Please dispose of this device according to 
the applicable legal regulations after its final decommissioning.

Heating oil

Fuels must be disposed of according to the local regulations.

Packaging

The packaging of the oil heating unit consists of cardboard/paper and 
plastic. The materials must be disposed of in the designated containers 
according to the local regulations or at a recycling depot.

16. Service and repair

Before contacting our customer service in order to solve an existing tech-
nical problem, please try removing the error by following the instructions 
described in the chapter "Troubleshooting".
If you have any further questions regarding the functioning and operation 
of the oil cleaning unit or if you wish to receive further information in 
the event of a claim or with regard to guarantee aspects, please do not 
hesitate to contact us at any time.
Please contact: 
Trotec GmbH Co KG
Grebbener Straße 7
D-52525 Heinsberg
Tel.:  49 (0) 2452 / 962 - 400
Fax.:  49 (0) 2452 / 962 - 200
Email: [email protected]
www.trotec.de.

17. Troubleshooting

Danger to life due to improper repair!

Do no attempt to carry out modifications or repairs on 
the device. Any unauthorised modification may result 
in serious injuries or even death. Have repairs carried 
out by a certified specialist workshop. 

Содержание IDS 100

Страница 1: ...IDS 100 EN OPERATION MANUAL OIL HEATER TRT BA IDS 100 HS 003 INT ...

Страница 2: ...eating unit for the first time Please store this operating manual and keep it within reach in order to consult it if necessary Please observe all safety instructions and information on use and main tenance contained in this manual This manual should be attached to the device if the latter is made avail able to other persons for use Legend WARNING SYMBOL This symbol is followed by a hazard warning ...

Страница 3: ...Do not apply any liquids to the interior of the device If this does happen nevertheless pull out the power cord and have the de vice checked by a specialist workshop Risk of injury Do not insert any objects into the intake and exhaust opening of the device Do not reach into the existing openings Do not leave children or animals unattended near the operating device Do not operate the device in room...

Страница 4: ... for people and property The following points are to be observed during installation The device may be operated indoors and in roofed outdoor areas The device must be installed in a stable position and placed on a fireproof surface The device must be installed near a chimney or external wall The device must be connected to a properly secured mains socket The installation room of the device must be...

Страница 5: ...e to a properly secured mains socket 230 V 50 Hz 10 A On construction sites a residual current circuit breaker must be connected upstream of the mains socket according to VDE 0100 0105 The oil heating unit is now ready for operation Use the device according to the functions described in chapter 12 Functions and operation 11 Exhaust system Before planning the installation of the exhaust system the ...

Страница 6: ...noz zle may be insufficient This will cause the flame control system to be activated and the device will be blocked Wait for approx 1 minute Press and hold the reset button for at least 5 seconds Switch on the device If the device is still not starting up Make sure that there is enough heating oil in the tank Press the reset button In order to determine the cause of the fault see the chapters Safe...

Страница 7: ... a wet cloth The painted and plastic surfaces may not be scoured Do not use any solvent based cleaning agents 15 Disposal The heating oil must be drained from the tank of the oil heating unit and collected Oil heating unit Electronic equipment may not be disposed of in the domestic waste but must be correctly disposed of in accordance with the EUROPEAN PARLIA MENT directive 2002 96 EC of 27th Janu...

Страница 8: ...ustomer service and have the device cleaned and heating oil residues removed from the combustion chamber Photoelectric cell defective Have the photoelectric cell replaced by the cus tomer service flashing red light or flashing red green light Motor winding interrupted or blown Have the motor replaced by the customer service Motor bearing blocked Have the motor bearing replaced by the customer serv...

Страница 9: ...s Have the position of the air setting ring checked by the customer service Have the support disc of the burner cleaned by the customer service Supply of combustion air too high Have the position of the air setting ring checked by the customer service used heating oil contami nated and or containing water Replace used heating oil with clean heating oil Clean the heating oil filter air has entered ...

Страница 10: ...ty thermostat FUA Fuse LI 2 Overheating protection thermostat L1 RV Selector switch EV 1 Solenoid valve I stage FA Air regulator EV 2 Solenoid valve II stage IT Ignition transformer LF RFI filter RF Heated filter optional DV Change over switch power stage high low TF Plug for heated filter TD Transformer Setting of the air setting ring A Type IDS 100 Parameter Value Setting of air setting ring A 1...

Страница 11: ......

Страница 12: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Отзывы: