Operating manual – IDS 100
EN
B-3
Fuels
The following fuels have been approved for use with the oil heating unit
IDS 100: heating oil EL, diesel
7. Proper and improper use
Proper use
The oil heating unit IDS 100 has been developed for the generation of hot
air and may be used indoors and in roofed outdoor areas.
The device can be used for heating large rooms such as storerooms,
workshops, building sites, greenhouses or cowsheds. It has been de-
signed for stationary operation without frequently changing locations.
The oil heating unit can be used in conjunction with an air transportation
hose.
Any application deviating from the above-mentioned use is deemed in-
admissible!
Improper use
The device may not be installed or operated in potentially inflammable
and explosive rooms or areas.
The device may not be used in rooms with an insufficient supply of com-
bustion air.
8. Installation conditions
When choosing the installation location of the oil heating unit, a number
of spatial and technical conditions must be taken into account. Any non-
compliance may impair the functioning of the device and/or of the acces-
sories or result in hazardous situations for people and property.
The following points are to be observed during installation:
•
The device may be operated indoors and in roofed outdoor areas.
•
The device must be installed in a stable position and placed on
a fireproof surface.
•
The device must be installed near a chimney or external wall.
•
The device must be connected to a properly secured mains
socket.
•
The installation room of the device must be sufficiently ventilated.
•
The minimum distance of the intake opening of the device to the
wall must be at least 1 m (see figure).
min. 1 m
•
The minimum distance of the device to inflammable materials
must be at least 2 m.
•
The intake and exhaust openings must not be covered.
•
There may be no walls or large objects near the device.
•
A sufficient number of fire-extinguishing systems must be available.
9. Description of device
The oil heating unit IDS 100 consists of the following components:
Oil heating unit
1
2 3 4 5
6
7
9
10
12
13
14
11
8
1 Combustion chamber
8 Heating oil filter
2 Burner
9 Heating oil circuit
3 Nozzle
10 Support and handle
4 Pump
11 Wheel
5 Solenoid valve
12 Tank
6 Fan motor
13 Burner motor
7 Fan
14 Combustion air regulator
Control panel
1
2
3
6
4
5
1 Reset button with indicator lamp
4 Change-over switch, power stage
2 Selector switch
(high-low)
(ventilation/heating, thermostat operation) 5 Lamp
3 Thermostat socket
6 Power supply cable
Содержание IDS 100