Trotec AIRGOCLEAN 200 E Скачать руководство пользователя страница 8

8

EN

air cleaner AirgoClean® 200 E

Setting the operating mode

The device comes with the following operating modes:

Automatic mode

Night mode

Turbo mode

Please proceed as follows to switch between operating modes:

ü

The device is switched on.

1. Press the 

Mode

 button (

15

).

ð

The corresponding 

Mode

 LED (

14

) lights up.

Automatic mode

When in automatic mode, the device automatically detects the
air quality.
Please proceed as follows to set the automatic mode:

ü

The device is switched on.

1. Press the 

Mode

 button (

15

) until the 

Auto

 LED (

14

) is

illuminated.

ð

If you press the 

Air quality

 button (

9

), the air quality will

also be measured.

After the device has been measuring the air quality, the
segment display (

5

) and the 

Air quality

 LED (

17

) will be

illuminated in the respective colour: blue, orange or red. The
segment display (

5

) indicates the measured PM2.5 value.

The fan speed will be changed depending on the air quality.
However, the 

Speed

 LED (

13

) will not indicate the fan speed in

automatic mode.

Air quality

 LED

Segment display 
(PM2.5 value)

Illuminated in blue (good air quality)

0-75

Illuminated in orange (medium air
quality)

76-150

Illuminated in red (poor air quality)

>150

The timer can be optionally activated in automatic mode.

Note

If the light sensor (

8

) detects dark surroundings in

automatic mode, the device automatically switches to

night mode

.

Info
Automatic mode and virus filtration

Do not use the automatic mode if the device is used for
virus filtration!
The integrated sensors only respond to air pollution
caused by fine particulates, pollen or possibly VOC
(organic chemical compounds). The device cannot
determine the virus load inside the room. It is possible
that the automatic mode indicates a "good air quality"
even though the virus load in the room is very high.
Therefore, when using the device for virus filtration, we
recommend that you always select a fixed performance
level adapted to the room size or the required
circulation rate.

Night mode

In 

night mode

, the device generates an air current that is

adapted to your sleep habits.
Proceed as follows to switch on night mode:

ü

Measuring the air quality is not activated and the 

Air quality

 LED (

17

) is not illuminated.

1. Press the 

Mode

 button (

15

) until the 

Sleep

 LED (

14

) is

displayed.

ð

The device is running at the lowest fan stage.

ð

The 

Speed

 LED (

13

) and the segment display (

5

) are not

illuminated.

Turbo mode

Note

In turbo mode, the room air is automatically disinfected
by means of negative ions. This additional function is
only available with activated turbo mode.

When in turbo mode, the device automatically detects the air
quality. The 

Air quality

 LED (

17

) is illuminated and the air

quality (PM 2.5 value) is indicated on the segment display (

5

).

Proceed as follows to switch on turbo mode:

1. Press the 

Mode

 button (

15

) until the 

Turbo

 LED (

14

) is

displayed.

ð

The device is running at the highest fan stage. The

Speed

 LED (

13

) is not illuminated.

Ventilation

Please proceed as follows to adjust the fan speed:

ü

The device is switched on.

1. Select the desired speed by repeatedly pressing the

Speed

 button (

12

).

ð

The 

Mode

 LED (

14

) goes out. The 

Speed

 LED (

13

)

indicates the selected fan speed.

Setting the timer

You can activate the automatic switch-off function after a preset
number of hours by means of the timer.
The number of hours can be set to 12 h, 24 h, 48 h or 72 h.

Содержание AIRGOCLEAN 200 E

Страница 1: ...TRT BA AIRGOCLEAN 200E TC2020 53 004 EN AIRGOCLEAN 200 E EN OPERATING MANUAL AIR CLEANER...

Страница 2: ...e manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock f...

Страница 3: ...ed Make sure that there are no loose items or dirt located in the immediate surroundings of air inlet and air outlet Do not remove any safety signs stickers or labels from the device Keep all safety s...

Страница 4: ...tion about the device Device description The device serves to filter the room air with the aim of reducing slight and medium contaminations and odours in order to improve the air quality It is equippe...

Страница 5: ...rry handle To make the device easier to transport it is fitted with wheels Before transporting the device observe the following Switch the device off Hold onto the mains plug while pulling the power c...

Страница 6: ...as described in the chapter Technical annex A B C C D Before restarting the device check the condition of the power cable If there are doubts as to the sound condition contact the customer service On...

Страница 7: ...y LED Is illuminated according to the air quality blue good orange medium red poor 18 HEPA carbon filter LED If the Replace indication is illuminated and the last bar of the LED is illuminated in red...

Страница 8: ...OC organic chemical compounds The device cannot determine the virus load inside the room It is possible that the automatic mode indicates a good air quality even though the virus load in the room is v...

Страница 9: ...15 for 3 seconds again to deactivate the function The device switches back to the previous operating mode Memory function If you switch the device back on from standby mode the settings selected for...

Страница 10: ...them The HEPA carbon filter is not installed Install the HEPA carbon filter Check the minimum distance to walls or other objects Position the device a little more in the room s centre if required The...

Страница 11: ...t screws X X Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign object...

Страница 12: ...openings of the device 3 Check the inside of the device for dirt 4 If you see a thick layer of dust clean the inside of the device with a vacuum cleaner 5 Reinsert the air filters Changing the HEPA ca...

Страница 13: ...se of the HEPA carbon filter according to the national regulations 6 Take the new HEPA carbon filter out of the plastic cover 7 Insert the new HEPA carbon filter into the device Make sure that the str...

Страница 14: ...3 h Ambient temperature 10 C to 45 C Operating range 0 to 95 RH Mains connection 220 240 V 50 Hz Power consumption 38 W Nominal current 0 17 A Sound pressure level 54 dB A Dimensions length x width x...

Страница 15: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...