Operating manual – Local air conditioner PAC 2000 E
10
Error code Display
Fault
Cause
Remedy
H3
n. a.
Compressor overload
protection
• The inside of the device is heavily contaminated Contact Trotec
• Air inlet or air outlet is blocked
Remove any foreign objects and dirt from the
air inlet and outlet.
Observe the minimum distances specified in
the technical data
• The fan does not run or runs too slowly
Contact Trotec
• Compressor malfunction: Temperature at the
housing is very high, compressor makes unusual
noises or refrigerant leaks
Contact Trotec
• The system is blocked on the inside
Contact Trotec
• Pump does not operate or condensate cannot be
discharged
Contact Trotec
• The rubber stopper at the condensate outlet is not
properly attached.
Check the rubber stopper for tight fit
• Refrigerant leaks
Contact Trotec
E8
n. a.
Overload malfunction
• The inside of the device is heavily contaminated Contact Trotec
• Air inlet or air outlet is blocked
Remove any foreign objects and dirt from the
air inlet and outlet.
Observe the minimum distances specified in
the technical data
• The fan does not run or runs too slowly
Contact Trotec
• Compressor malfunction: Temperature at the
housing is very high, compressor makes unusual
noises or refrigerant leaks
Contact Trotec
• The system is blocked on the inside
Contact Trotec
• The temperature sensor on the mainboard cannot
determine temperature
Contact Trotec